Intel RAID AXXRSBBU6 user manual

User manual for the device Intel RAID AXXRSBBU6

Device: Intel RAID AXXRSBBU6
Category: Computer Accessories
Manufacturer: Intel
Size: 0.49 MB
Added : 12/15/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Intel RAID AXXRSBBU6. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Intel RAID AXXRSBBU6.

For your convenience

If looking through the Intel RAID AXXRSBBU6 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Intel RAID AXXRSBBU6 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Intel RAID AXXRSBBU6 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Intel RAID AXXRSBBU6 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Intel RAID AXXRSBBU6 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Intel RAID AXXRSBBU6. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


®
Intel RAID Smart Battery
AXXRSBBU6
User’s Guide

Order Number: E33722-001


Summary of the content on the page No. 2

Warranty Notice: Adding a battery on an Intel RAID controller will limit the warranty of this product. Returns determined to be caused by battery installation damage, stripped screws, or other damage resulting from the battery installation will not be covered. ESD damage to the board will also not be covered by the warranty. The warranty on the AXXRSBBU6 is 1 year. Disclaimer ® Information in this document is provided in connection with Intel pro

Summary of the content on the page No. 3

Contents List of Figures..................................................................................................... iv List of Tables ...................................................................................................... iv ® About the Intel RAID Smart Battery...................................................................i Installing the AXXRSBBU6................................................................................. 3 Important Pre-installation C

Summary of the content on the page No. 4

List of Figures Figure 1. Top and Bottom View of the AXXRSBBU6...................................................................3 ® Figure 2. Battery alignment on the add-in Intel RAID Controllers ..............................................5 Figure 3. Battery board mounting on RAID controller board........................................................5 Figure 4. Reinserting an add-in RAID Controller .........................................................................6 Figur

Summary of the content on the page No. 5

® About the Intel RAID Smart Battery ® ® Intel RAID Controllers and Intel Integrated Server RAID Modules provide reliability, high performance, and fault-tolerant disk subsystem management. A complete fault-tolerant strategy requires protection for all data, including the unwritten cached data in the RAM cache. If power is lost, the data in RAM is lost. To avoid this data loss, a battery can be added to supply power to the RAID RAM during an AC power outage or if the AC power cord is rem

Summary of the content on the page No. 6

Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See Intel Server Boards and Server Chassis Safety Information at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warn- und Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel- Serverplatinen un

Summary of the content on the page No. 7

Installing the AXXRSBBU6 Figure 1 displays the top and bottom views of the AXXRSBBU6. The battery pack is mounted on a daughtercard which mounts to the RAID controller. Take note of the location of the J2 connector ® (5) which plugs into the Intel RAID Controller and the 3 standoffs (2) and 6 screws (3). Only the top side of the daughtercard will be visible after installation onto the RAID controller. Figure 1. Top and Bottom View of the AXXRSBBU6 1. J4 battery pack harness conn

Summary of the content on the page No. 8

Important Pre-installation Considerations Warning: Always ground yourself and/or use a ground strap before touching the RAID controller or the RSBBU. Perform all installation work at an ESD-safe workstation. Use an ESD-safe Phillips screwdriver set to a maximum torque of 2.25 inch pounds, and be sure the screwdriver is centered in the screw to avoid damaging the screw head. If you exceed the maximum torque specification, you may damage the board, connectors, or screws, and you will void t

Summary of the content on the page No. 9

4. Remove the protective metal cover from the battery connector on the RAID controller ® ® card. (J10 on the Intel SRCSASBB8I and Intel SRCSASLS4I.) ® ® 5. On the Intel RAID Controller SRCSASBB8I and the Intel RAID Controller SRCSASLS4I, place the RAID controller with the components facing up. ® Figure 2. Battery alignment on the add-in Intel RAID Controllers 6. Hold the AXXRSBBU6 so that the battery side is up and the three screw holes align. Figure 3. Battery board mounting o

Summary of the content on the page No. 10

Caution: Center the screwdriver carefully to avoid stripping the screwhead. Do not over-tighten the screws. The maximum recommended torque is 2.25 inch pounds. ® C. Place the Intel RAID Controller back into the server 1. Align the RAID controller with the PCI Express* slot. 2. Press down gently, but firmly, to ensure that the RAID controller is properly seated in the slot. The bottom edge of the RAID controller must be flush with the slot. Caution: Never apply pressure to the AXXRSBB

Summary of the content on the page No. 11

Monitoring Battery Backup Multiple utilities are available to display and configure BBU information including recharge count. When you replace a BBU, you should reset this counter to zero. Intel recommends that you replace the BBU once per year or after 500 recharge cycles, whichever comes first. Note: This chapter describes only the BBU-related features of the Intel utility programs. For ® complete information on these utilities, see the Intel RAID Software User’s Guide. Monitoring

Summary of the content on the page No. 12

Most of the Battery Module properties are view-only. In the lower right panel of the RAID BIOS Console there are two properties that can be changed. (Intel recommends that you leave these properties at their default settings.) • Learn Delay Interval – default 30 days • Auto Learn Mode – default Auto Note: The learning cycle is a battery calibration operation performed by the controller periodically to determine the condition of the battery. ® Using Intel RAID Web Console 2 ® The stat

Summary of the content on the page No. 13

• The current BBU temperature, voltage, current, and remaining capacity • The estimated time until the battery is fully charged (only if the battery is charging) Replacing Battery Backup Units Intel recommends that you replace BBUs once a year or after 500 recharging cycles, whichever comes first. The warranty on the battery pack is for one year. After you install a new BBU, use one of the Intel configuration utilities to reset the battery recharge cycle counter to zero. For instructio

Summary of the content on the page No. 14

Battery Backup Unit Specifications Table 1. Battery Backup Unit Specifications Battery Technology LiON (Lithium ION) 1 cell 10–45°C ambient temperature Battery Operating Environment 20% to 80% humidity non-condensing Depends on storage time,:< 30 days: 0–50 °C Battery Storage Temperature 30–90 days: 0–40 °C ‘; > 90 days: 0–30 °C Fast Charge Current 500mAH using charge circuitry card Battery Voltage Nominal OCV: 3.7 V Mechanical 2.611 inches x 2.122 inches Battery Capacity


Alternative user manuals
# User manual Category Download
1 Intel NetStructure Cache Appliance 1520 User manual Computer Accessories 0
2 Intel Evaluation Platform Board Manual RN User manual Computer Accessories 1
3 Intel HP Workstation xw455Q User manual Computer Accessories 2
4 Intel LXD970A User manual Computer Accessories 2
5 Intel OPEN (660) 120/140/150 II User manual Computer Accessories 1
6 Intel Evaluation Platform Board Manual IQ80960RM User manual Computer Accessories 1
7 Intel TOUCH-N-MOW 120000 User manual Computer Accessories 1
8 Intel Remote Management Module 4 User manual Computer Accessories 7
9 Intel ARCHITECTURE IA-32 User manual Computer Accessories 3
10 Intel CONTROLLERS 413808 User manual Computer Accessories 0
11 Intel CELERON 200 User manual Computer Accessories 24
12 Intel LXD970A Demo Board for 10/100 User manual Computer Accessories 1
13 Intel SR1450 User manual Computer Accessories 3
14 Intel 4.0A User manual Computer Accessories 1
15 Sony VGC-RB50(G) User manual Computer Accessories 1
16 Sony Movie Studio HD Platinum Suite 11 MSPSMS11000 User manual Computer Accessories 177
17 Sony Hi-MD Walkman MCMD-R1 User manual Computer Accessories 7
18 Sony Sound Forge V.10.0 Pro SF-10000 User manual Computer Accessories 435
19 Sony Rechargable Battery Pack VGP-BPSC31 User manual Computer Accessories 23