FieldServer ControlNet FS-8700-104 user manual

User manual for the device FieldServer ControlNet FS-8700-104

Device: FieldServer ControlNet FS-8700-104
Category: Computer Drive
Manufacturer: FieldServer
Size: 0.07 MB
Added : 6/13/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FieldServer ControlNet FS-8700-104. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FieldServer ControlNet FS-8700-104.

For your convenience

If looking through the FieldServer ControlNet FS-8700-104 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FieldServer ControlNet FS-8700-104 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FieldServer ControlNet FS-8700-104 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FieldServer ControlNet FS-8700-104 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FieldServer ControlNet FS-8700-104 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FieldServer ControlNet FS-8700-104. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




A Sierra Monitor Company

Driver Manual
(Supplement to the FieldServer Instruction Manual)

FS-8700-104 ControlNet X30 Driver



APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after May 1, 2001
Driver Version: 1.01
Document Revision: 7

Summary of the content on the page No. 2

FS-8700-104_ControlNet_X30 Manual Table of Contents TABLE OF CONTENTS 1. CONTROLNET X30 DESCRIPTION .................................................................................3 2. DRIVER SCOPE OF SUPPLY...........................................................................................4 2.1. Supplied by FieldServer Technologies for this driver ...................................................4 rd 2.2. Provided by the Supplier of 3 Party Equipment......................

Summary of the content on the page No. 3

FS-8700-104_ControlNet_X30 Manual Page 3 of 13 1. ControlNet X30 Description The FieldServer ControlNet X30 driver can be used to emulate a single slave station on a ControlNet network. ControlNet scanners can open a connection of up to 450 Bytes in each direction to the FieldServer. Data transfers are via Scheduled Communication and therefore the FieldServer has to be scheduled on the ControlNet network using a Network Configuration Tool such as RSNetWorx or RSLogix. The minim

Summary of the content on the page No. 4

FS-8700-104_ControlNet_X30 Manual Page 4 of 13 2. Driver Scope of Supply 2.1. Supplied by FieldServer Technologies for this driver FieldServer Technologies Description PART # FS-8700-104 Driver Manual. X30-ControlNet Anybus ControlNet Card rd 2.2. Provided by the Supplier of 3 Party Equipment rd 2.2.1. Required 3 Party Software RSNetWorx, RSLogix or another Network Scheduling Tool. rd 2.2.2. Required 3 Party Configuration Connection to a properly terminated ControlNet netw

Summary of the content on the page No. 5

FS-8700-104_ControlNet_X30 Manual Page 5 of 13 3. Hardware Connections The FieldServer is connected to the ControlNet network as shown in the connection drawing below. 3.1. Hardware Connection Tips / Hints Use the recommended network cable and terminators as specified by the ControlNet network organization and/or the manufacturer of your network equipment. FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com Tel: (408) 262-2299

Summary of the content on the page No. 6

FS-8700-104_ControlNet_X30 Manual Page 6 of 13 4. Configuring the FieldServer as a ControlNet Server For a detailed discussion on FieldServer configuration, please refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (See “.csv” files on the driver CD). This section documents and describes the parameters necessary for configuring the FieldServer

Summary of the content on the page No. 7

FS-8700-104_ControlNet_X30 Manual Page 7 of 13 4.2. Server Side Connection Descriptors Section Title Connections Column Title Function Legal Values Adapter Adapter Name ControlNet Example // Server Side Connections Connections Adapter ControlNet 4.3. Server Side Node Descriptors Section Title Nodes Column Title Function Legal Values Node_Name Provide name for node Up to 32 alphanumeric characters Protocol Specify protocol used Anybus ControlNet Example //

Summary of the content on the page No. 8

FS-8700-104_ControlNet_X30 Manual Page 8 of 13 4.4. Server Side Map Descriptors 4.4.1. FieldServer Specific Map Descriptor Parameters Column Title Function Legal Values Up to 32 alphanumeric Map_Descriptor_Name Name of this Map Descriptor characters Name of Data Array where One of the Data Array names Data_Array_Name data is to be stored in the from “Data Array” section FieldServer above Starting location in Data 0 to maximum specified in Data_Array_Offset Array “Data Array” s

Summary of the content on the page No. 9

FS-8700-104_ControlNet_X30 Manual Page 9 of 13 4.4.3. Map Descriptor Example. // Client side Map Descriptors Map_Descriptors Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function, Node_Name, CNT_Data_Type, Address, Length, Scan_Interval Get_Data, Input_Data, 0, RDBC, CN5, WORD, 0, 225, 1s Put_Data, Output_Data, 0. WRBC, CN5, WORD, 4, 225, 1s Read function map Write function map descriptor gets data Note the start Note that each address descrip

Summary of the content on the page No. 10

FS-8700-104_ControlNet_X30 Manual Page 10 of 13 Appendix A. Advanced Topics Appendix A.1. ControlNet X30 LED indicators LED 1 – Module status Color Frequency Description Green Flashing Module is waiting for initialisation Green Steady on Module is initialised Red Flashing Minor fault, MacID has been changed after initialisation, etc. Red Steady on Major fault, module must be restarted LED 2 – LED Channel A Color Frequency Description Red/Green - See Channel LEDs below

Summary of the content on the page No. 11

FS-8700-104_ControlNet_X30 Manual Page 11 of 13 Channel LEDs Channel LEDs Description A and B, steady off Module is not initialised A and B, steady red Faulted unit, must be restarted or repaired A and B, alternating red/green Selftest of bus controller A and B, flashing red Incorrect node configuration, duplicate MacID, etc. A or B, steady off Channel is disabled, depending on network configuration A or B, steady green Normal operation of channel A or B, flashing green Temporary

Summary of the content on the page No. 12

FS-8700-104_ControlNet_X30 Manual Page 12 of 13 information on the settings for the CONTROLNET-MODULE profile with AnyBus-S enabled devices. Name: (choose a unique name for this module) Description: (self-explanatory and optional) Comm Format: Select ‘Data - INT’ Node: Select the ControlNet node number for this device Input Assembly Instance: 100 Size: Varies with how the module is intialized Note: The ControlNet module uses a ControlNet 32-bit run/idle header, so the actua

Summary of the content on the page No. 13

FS-8700-104_ControlNet_X30 Manual Page 13 of 13 Appendix B. Driver Notes Appendix B.1. Setting the FieldServer’s ControlNet MAC ID The MAC ID can be set in the FieldServer’s CSV file using the System_Station_Address, (refer to Section 4.1), or it can be set with the two rotary switches as indicated on the connection diagram. The left switch selects the left decimal digit and the right switch the right decimal digit of the MAC ID. Note that the software setting with the System_Sta

Summary of the content on the page No. 14


Alternative user manuals
# User manual Category Download
1 FieldServer FS-8700-01 User manual Computer Drive 0
2 FieldServer FS-8700-114 X30 User manual Computer Drive 0
3 FieldServer FS-8700-64 User manual Computer Drive 0
4 FieldServer Carrier DataPort FS-8700-86 User manual Computer Drive 2
5 FieldServer FS-8700-80 User manual Computer Drive 1
6 FieldServer FS-8700-103 User manual Computer Drive 1
7 FieldServer Dart FS-8700-78 User manual Computer Drive 1
8 FieldServer Gamewell FS-8700-83 User manual Computer Drive 2
9 FieldServer Data Aire (DAP) FS-8704-49 User manual Computer Drive 15
10 FieldServer FS-8700-105 User manual Computer Drive 1
11 FieldServer A Sierra Monitor Company X30 User manual Computer Drive 2
12 FieldServer FS-8700-73 User manual Computer Drive 1
13 FieldServer FS-8700-03 DF1 User manual Computer Drive 1
14 FieldServer Gardner Denver FS-8700-60 User manual Computer Drive 11
15 FieldServer Canatal Satchnet Driver FS-8700-59 User manual Computer Drive 3
16 Sony MSH-128S2 User manual Computer Drive 2
17 Sony 2GB Flash Drive USM2GLX User manual Computer Drive 0
18 Sony SAITE1300-F User manual Computer Drive 0
19 Sony CRX - 160E User manual Computer Drive 0
20 Sony 2GN User manual Computer Drive 0