Stellar Industries 11 SEER H*DE024 - 60 user manual

User manual for the device Stellar Industries 11 SEER H*DE024 - 60

Device: Stellar Industries 11 SEER H*DE024 - 60
Category: Air Conditioner
Manufacturer: Stellar Industries
Size: 2.57 MB
Added : 5/10/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Stellar Industries 11 SEER H*DE024 - 60. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Stellar Industries 11 SEER H*DE024 - 60.

For your convenience

If looking through the Stellar Industries 11 SEER H*DE024 - 60 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Stellar Industries 11 SEER H*DE024 - 60 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Stellar Industries 11 SEER H*DE024 - 60 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Stellar Industries 11 SEER H*DE024 - 60 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Stellar Industries 11 SEER H*DE024 - 60 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Stellar Industries 11 SEER H*DE024 - 60. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION
STELLAR
INSTRUCTIONS
AIR CONDITIONING UNIT
SPLIT-SYSTEM COOLING
CONTENTS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOCATION . . . . . . . . . .

Summary of the content on the page No. 2

550.38-N1Y Installer should pay particular attention to the words: NOTE, GENERAL CAUTION and WARNING. This instruction covers the installation of the following Stellar NOTES are intended to clarify or make the installation easier. air conditioning units. CAUTIONS are given to prevent equipment damage. NOMENCLATURE WARNINGS are given to alert the installer that personal H 4 DB 030 S 06 injury and/or equipment damage may

Summary of the content on the page No. 3

550.38-N1Y TO WEATHERPROOF THERMOSTAT BLOWER DISCONNECT 48” OVERHEAD MOTOR SWITCH CLEARANCE TO POWER 12” REAR RELAY REQUIRED SUPPLY AND SIDES CLEARANCE NEC CLASS 1 REQUIRED WIRING Sit unit on rubber NEC CLASS 2 elevator WIRING grommets TO to reduce COIL noise and allow for proper drainage. NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF 24” SERVICE ACCESS CLEARANCE REQUIRED SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT FIGURE 1: TYPICAL INSTALLATION Normal operating sound levels may be o

Summary of the content on the page No. 4

550.38-N1Y Coil is under 30 PSIG helium pressure. Relieve pres- sure from schrader valve on liquid line side. !" # $ % # " & & $ ’ This fitting is a right-hand thread, turn counter-clock- wise to remove. 1. First, relieve the holding charge by depressing the Schrader valve located in the end of the liquid line. 2. Remove the liquid line fitting using 3/4" wren

Summary of the content on the page No. 5

550.38-N1Y Ensure the bulb is making maximum contact. Refer to TXV installation instruction for view of bulb location. The evaporator coil is under 30 psig pressure. 2. After holding charge is completely discharged, loosen and remove the liquid line fitting from the orifice distributor In all cases, mount the TXV bulb after vapor line is assembly. Note that the fitting has right hand threads. brazed and has had sufficient time to cool. 3. Remove the orifice from the distributor body using a sma

Summary of the content on the page No. 6

550.38-N1Y 4. The vapor line must be insulated with a minimum of 1/2" foam rubber insulation (Arm-A-Flex or equivalent). Liquid lines that will be exposed to direct sunlight and/or high temperatures must also be insulated. Dry nitrogen should always be supplied through the Tape and suspend the refrigerant lines as shown. DO NOT tubing while it is being brazed, because the tempera- allow metal-to metal contact. See Figure 4. ture required is high enough to cause oxidation of the copper unless an

Summary of the content on the page No. 7

550.38-N1Y 7. Replace the schrader cores in the liquid and vapor valves. 8. Evacuate the vapor line, evaporator and the liquid line, to 500 microns or less. 9. Leak test all refrigerant piping connections including the service port flare caps to be sure they are leak tight. DO NOT OVERTIGHTEN (between 40 and 60 inch - lbs. maximum). NOTE: Do not use the system refrigerant in the outdoor unit to purge or leak test. 10. Replace caps on service ports. Do not remove the flare caps from the service

Summary of the content on the page No. 8

550.38-N1Y ate the system down to at least 500 microns to eliminate POWER CONTROL contamination and moisture in the system. WIRING WIRING LOW VOLTAGE JUNCTION BOX GROUND Never attempt to repair any brazed connections while LUG the system is under pressure. Personal injury could result. See “SYSTEM START-UP” on page 9 for checking and recording system charge. GENERAL INFORMATION & GROUNDING Check the electrical supply to be sure that it meets the values specified on the unit nameplate and wir

Summary of the content on the page No. 9

550.38-N1Y The “TOTAL SYSTEM CHARGE” must be permanently 1. Operate system until temperatures and pressures stabi- stamped on the unit data plate. lize (minimum of 10 minutes). 2. Measure and record indoor wet bulb (WB) temperature Total system charge is determined as follows: using a sling psychrometer and the outdoor dry bulb (DB) temperature using a thermometer. 1. Determine outdoor unit charge from tabular data sheet. 3. Measure and record the suction pressure at the suction 2. Determine ind

Summary of the content on the page No. 10

550.38-N1Y 2 3 , )4 5 ) *+, )-*. /. 0* # / + ( GROUND. ) - * . / . 1 * 2 ) 3 LUG ! "

Summary of the content on the page No. 11

550.38-N1Y                                             ,-./,0 /0 1, 1,0 /0 1, /-,.230 /0 3, 3430 /0 1, 2 / 5 3/ 1, ! " # ! $

Summary of the content on the page No. 12

550.38-N1Y Table 1: SUPERHEAT VALUE OUTDOOR DB°F INDOOR WB 1 °F 55 60 65 70 75 80 85 90 95 100 105 110 115 50 9 7 52 12 10 6 54 14 12 10 7 56 17 15 14 10 6 58 20 18 16 13 9 5 60 23 21 19 16 12 8 6 62 26 24 22 19 16 12 8 5 64 29 27 24 21 18 15 11 9 6 66 32 31 30 24 23 18 15 11 9 6 68 35 33 30 27 24 21 19 16 14 12 9 6 70 35 33 30 28 25 22 20 18 15 13 11 8 72 35 33 30 28 26 24 20 20 17 15 14 74 34 31 30 27 25 23 22 20 18 76 35 33 31 29 27 26 25 23 1. Evaporator Entering Air °F Table 2: TEMPERATURE

Summary of the content on the page No. 13

550.38-N1Y SYSTEM CONTROLLER - HDB076 ONLY INDICATIONS OF PROPER OPERATION Controls operation as follows: Cooling operation is the same as any conventional air condi- tioning unit. 1. RANDOM START - Upon initial application of power and a 2.5 second time delay, the compressor contactor will The following checks may be made to determine if the sys- be energized. tem is operating properly: 2. ANTI-SHORT CYCLE - Once the unit is energized, a 1. The outdoor fan should be running, with warm air being

Summary of the content on the page No. 14

550.38-N1Y NOTES: 14 Unitary Products Group

Summary of the content on the page No. 15

550.38-N1Y NOTES: Unitary Products Group 15

Summary of the content on the page No. 16

550.38-N1Y NOTES: Heating and Air Conditioning Unitary Products Group 5005 York Drive, Norman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A. Copyright © by Unitary Products Group 1999. All rights reserved. Supersedes: 550.38-N1Y (899) 550.38-N1Y (999)


Alternative user manuals
# User manual Category Download
1 Stellar Industries 50 Hz H*DA018-076 User manual Air Conditioner 0
2 Stellar Industries 10 SEER H*DB012 - 76 User manual Air Conditioner 0
3 Stellar Industries 12 SEER H*DH018 - 60 User manual Air Conditioner 0
4 Sony SU-PW2 User manual Air Conditioner 12
5 Sony CV-P12PX User manual Air Conditioner 3
6 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
7 Sony VGN-BX500 User manual Air Conditioner 1
8 Philips 190S5 User manual Air Conditioner 21
9 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
10 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
11 Philips CS-E15DB4EW User manual Air Conditioner 4
12 Philips GOGEAR SA3425 User manual Air Conditioner 1
13 Philips 3160 User manual Air Conditioner 7
14 Philips Comfort-Cire AMW User manual Air Conditioner 3
15 Philips Comfort-Cire AMC 25 User manual Air Conditioner 2