Vinotemp 4500SSH user manual

User manual for the device Vinotemp 4500SSH

Device: Vinotemp 4500SSH
Category: Air Conditioner
Manufacturer: Vinotemp
Size: 0.23 MB
Added : 5/24/2014
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vinotemp 4500SSH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vinotemp 4500SSH.

For your convenience

If looking through the Vinotemp 4500SSH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vinotemp 4500SSH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vinotemp 4500SSH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vinotemp 4500SSH User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vinotemp 4500SSH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vinotemp 4500SSH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



WINEMATE Split System

Installation, Operation & Care Manual




WM 2500SSH, 4500SSH
WM 6500SSH, 8500SSH











Vinotemp International Corp.
Vinotemp International Corp.


www.vinotemp.com
www.vinotemp.com

Summary of the content on the page No. 2

TABLE OF CONTENTS Important Safety Information…..........................................2 Feature Description…………………………….……………..3 Installation Instruction………………………………………..5 Use and Temperature Control……………………………….9 Care Guide……………………………………………………11 Troubleshooting……………………………………………..12 Customer Support……………………………………………14 Warranty……………………………………………………….15

Summary of the content on the page No. 3

Important Safety Information • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 AMPCIRCUIT IS HIGHLY RECOMMENDED. - 2 -

Summary of the content on the page No. 4

Feature Description • WineMate cooling unit is designed and used to provide a stable temperature between 52~62 °F for suitable space at a normal environment. • The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid. • These temperatures and humilities are optimized for long term storage of wine, fur and tobacco. • SSH units are designed to provide chilled air to wine rooms and can be located up to 25 ft away to reduce noise. •

Summary of the content on the page No. 5

Evaporator Unit Condensing Unit - 4 -

Summary of the content on the page No. 6

Installation Instruction Federal law requires that WINEMATE split cooling systems be installed by an EPA certified refrigeration technician. 1. Location • Place the condensing unit in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly. • Leave minimum 3 feet clearance between the exhaust side and the wall. • Leave minimum 1 foot clearance for the fresh air supply side. • Condensing u

Summary of the content on the page No. 7

Installation of the system must be done in accordance with all state and local building codes. The condensing unit and unit cooler are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested. If no leaks are found, evacuate and charge system with R134A. Refrigerant amount will vary depending on the

Summary of the content on the page No. 8

• If the air sensor can not reach the wine room because of the distance between the cooling unit and wine room, you need to remount the electrical box. • Remove the 3 black, white and green wires that come from the cooling unit in the electrical terminal • Remove the electrical box and mount it close to the wine room so the air sensor can reach the wine room • Use extra wires to connect the terminal in the electrical box and the 3 white, black and green wires from the cooling unit.

Summary of the content on the page No. 9

6500SSH Electrical Wiring Diagram 8500SSH Electrical Wiring Diagram - 8 -

Summary of the content on the page No. 10

Use & Temperature Control 1. Temperature Setting • Set the temperature at 55 °F for the optimum aging of wine • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize the temperature for each new temperature setting operation 2. Use of the controller Dip Switch Setting

Summary of the content on the page No. 11

1) Set Point Rotate the circular selector in correspondence with the arrow placed nearby. The selector represents -33°F to 50°F (-35°C to +10°C) for low temperature models, and 14°F to 68°F (-10°C to +20°C) for medium temperature models. “10” is the coldest setting, “1” is the warmest. 2) Differential It is possible to modify the differential from 1°F minimum to 12.5°F maximum. Simply shift the first two dip-switches to the ON or OFF position according to the wanted value. 3) Defro

Summary of the content on the page No. 12

Care Guide In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty. • Plug cooling system or reconnect power. 2. Moisture Removing • Remove the extra condensate if it is accumulated in the wine cellar at high ambien

Summary of the content on the page No. 13

Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1. Unit not running a. Power cord unplugged a. Check for power cord plug b. No power to unit b. Check power at receptacle & fuses c. Temperature setting high c. Lower temperature setting d. Low voltage. d. Contact an authorized electrician e. Incorrect or loose

Summary of the content on the page No. 14

g. Low voltage g. Check power supply h. Operating 60 Hz unit at 50Hz h. Use proper 60 Hz i. Sealed system problem i. Call service for checking loss of refrigerant or restrictions j. Undercharge or overcharge j. Call service to add or remove refrigerant 7. House circuit tripping a. Incorrect fuse or breaker a. Check for proper fuse or breaker b. Incorrect wirings b. Check for wirings and connections c. Failed components c. Call service 8. Noisy operation a. Mounting area not

Summary of the content on the page No. 15

Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 14 -

Summary of the content on the page No. 16

Warranty Thank you for choosing a Vinotemp wine cellar. Please enter the complete model and serial numbers in the space provided: Model_________________________________________________________ Serial No.______________________________________________________ Attach your purchase receipt to this owner’s manual. 1. Limited Warranty VINOTEMP warrants its products, parts only, to be free from defects due to workmanship or materials under normal use and service for

Summary of the content on the page No. 17

VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect. 2. Limitation of Implied Warranty VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT. VINOTEMP SHALL NOT BE LIABLE FOR: DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN


Alternative user manuals
# User manual Category Download
1 Vinotemp WINEMATE WM2500 SSW User manual Air Conditioner 0
2 Vinotemp WM 6500SSH User manual Air Conditioner 0
3 Vinotemp WM 2500SSH User manual Air Conditioner 0
4 Vinotemp 8500SSH User manual Air Conditioner 0
5 Vinotemp WINEMATE WM1500 SSW User manual Air Conditioner 0
6 Sony SU-PW2 User manual Air Conditioner 12
7 Sony CV-P12PX User manual Air Conditioner 3
8 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
9 Sony VGN-BX500 User manual Air Conditioner 1
10 Philips 190S5 User manual Air Conditioner 21
11 Philips Comfort-Cire AMC 45 User manual Air Conditioner 7
12 Philips Comfort-Cire AMC 30 User manual Air Conditioner 2
13 Philips CS-E15DB4EW User manual Air Conditioner 4
14 Philips GOGEAR SA3425 User manual Air Conditioner 1
15 Philips 3160 User manual Air Conditioner 7