IBM user manual

User manual for the device IBM

Device: IBM
Category: Computer Hardware
Manufacturer: IBM
Size: 3.57 MB
Added : 10/30/2014
Number of pages: 58
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for IBM . Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with IBM .

For your convenience

If looking through the IBM user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual IBM on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual IBM to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
IBM User manual - Online PDF
Advertisement
« Page 1 of 58 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual IBM but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to IBM . If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Redbooks
Paper
Dino Quintero
Sven Meissner
Andrei Socoliuc
Hardware Management Console
(HMC) Case Configuration Study for
LPAR Management
This IBM® Redpaper provides Hardware Management Console (HMC)
configuration considerations and describes case studies about how to use the
HMC in a production environment. This document does not describe how to
install the HMC or how to set up LPARs. We assume you are familiar with the
HMC. Rather, the case studies presented in this Redpaper provide a

Summary of the content on the page No. 2

 Automation  High availability considerations for HMCs Introduction and overview The Hardware Management Console (HMC) is a dedicated workstation that allows you to configure and manage partitions. To perform maintenance operations, a graphical user interface (GUI) is provided. Functions performed by the HMC include:  Creating and maintaining a multiple partition environment  Displaying a virtual operating system session terminal for each partition  Displaying a virtual operator panel of

Summary of the content on the page No. 3

Table 1 Types of HMCs Type Supported managed HMC code version systems 1 7315-CR3 (rack mount) POWER4 or POWER5 HMC 3.x, HMC 4.x, or HMC 5.x 1 7315-C04 (desktop) POWER4 or POWER5 HMC 3.x, HMC 4.x, or HMC 5.x 7310-CR3 (rack mount) POWER5 HMC 4.x or HMC 5.x 7310-C04 (desktop) POWER5 HMC 4.x or HMC 5.x 1 - Licensed Internal Code needed (FC0961) to upgrade these HMCs to manager POWER5 systems. A single HMC cannot be used to manage a mixed environment of POWER4 and POWER5 systems. The HMC 3.x cod

Summary of the content on the page No. 4

The maximum number of HMCs supported by a single POWER5 managed system is two. The number of LPARs managed by a single HMC has been increased from earlier versions of the HMC to the current supported release as shown in Table 3. Table 3 HMC history HMC code No. of No. of No. of Other information HMCs servers LPARs 4.1.x 1 4 40 iSeries Only 4.2.0 2 16 64 p5 520 550 570 4.2.1 2 32 160 OpenPower 720 4.3.1 2 32 254 p5 590 595 4.4.0 2 32 254 p5 575 HMC 7310-CR3/C04 4.5.0 2 32/48 254 48 for non

Summary of the content on the page No. 5

menus. However not all POWER5 servers support this mechanism of allocation. Currently p575, p590, and p595 servers support only DHCP. Note: Either eth0 or eth1 can be a DHCP server on the HMC.  HMC to partitions: HMC requires TCP/IP connection to communicate with the partitions for functions such as dynamic LPAR and Service Focal Point.  Service Agent (SA) connections: SA is the application running on the HMC for reporting hardware failures to the IBM support center. It uses a modem for

Summary of the content on the page No. 6

multi-threading. SMT is a feature supported only in AIX 5.3 and Linux at an appropriate level.  Multiple operating system support: Logical partitioning allows a single server to run multiple operating system images concurrently. On a POWER5 system the following operating systems can be installed: AIX 5L™ Version 5.2 ML4 or later, SUSE Linux Enterprise Server 9 Service Pack 2, Red Hat Enterprise Linux ES 4 QU1, and i5/OS. Additional memory allocation in a partitioned environment Three memor

Summary of the content on the page No. 7

To calculate your desired and maximum memory values accurately, we recommend that you use the LVT tool. This tool is available at: http://www.ibm.com/servers/eserver/iseries/lpar/systemdesign.htm Figure 1 shows an example of how you can use the LPAR validation tool to verify a memory configuration. In Figure 1, there are 4 partitions (P1..P4) defined on a p595 system with a total amount of 32 GB of memory. Figure 1 Using LVT to validate the LPAR configuration Hardware Management Console (

Summary of the content on the page No. 8

The memory allocated to the hypervisor is 1792 MB. When we change the maximum memory parameter of partition P3 from 4096 MB to 32768 MB, the memory allocated to the hypervisor increases to 2004 MB as shown in Figure 2. Figure 2 Memory used by hypervisor Figure 3 is another example of using LVT when verifying a wrong memory configuration. Note that the total amount of allocated memory is 30 GB, but the maximum limits for the partitions require a larger hypervisor memory. Figure 3 An examp

Summary of the content on the page No. 9

Micro-partitioning With POWER5 systems, increased flexibility is provided for allocating CPU resources by using micropartitioning features. The following parameters can be set up on the HMC:  Dedicated/shared mode, which allows a partition to allocate either a full CPU or partial units. The minimum CPU allocation unit for a partition is 0.1.  Minimum, desired, and maximum limits for the number of CPUs allocated to a dedicated partition.  Minimum, desired and maximum limits for processor u

Summary of the content on the page No. 10

Note: Take into consideration that changes in the profile will not get activated unless you power off and start up your partition. Rebooting of the operating system is not sufficient. Capacity on Demand The Capacity on Demand (CoD) for POWER5 systems offers multiple options, including:  Permanent Capacity on Demand: – Provides system upgrades by activating processors and/or memory. – No special contracts and no monitoring are required. – Purchase agreement is fulfilled using activation keys.

Summary of the content on the page No. 11

HMC sample scenarios The following examples illustrate POWER5 advance features. Examples of using capped/uncapped, weight, dynamic LPAR and CoD features Our case study describes different possibilities to take advantage of the micropartitioning features and CoD assuming a failover/fallback scenario based on two independent servers. The scenario does not address a particular clustering mechanism used between the two nodes. We describe the operation by using both the WebSM GUI and the command

Summary of the content on the page No. 12

P550 – 2 CPU - 8GB P550 – 4 CPU – 8 GB nils (production) julia (standby) Cluster 2 CPUs (dedicated) 0.2 CPU (shared) 7 GB 1024 MB Oli (production) 1 CPU (dedicated) 5120 MB Nicole_vio 0.8 CPU (shared) 1024 MB HMC 1 HMC 2 Figure 4 Initial configuration Table 5 shows our configuration in detail. Our test system has only one 4-pack DASD available. Therefore we installed a VIO server to have sufficient disks available for our partitions. Table 5 CPU and memory allocation table Partition C

Summary of the content on the page No. 13

Table 6 Memory allocation Memory (MB) Partition name Min Desired Max nicole_vio 512 1024 2048 oli 1024 5120 8192 julia 512 1024 8192 Enabling ssh access to HMC By default, the ssh server on the HMC is not enabled. The following steps configure ssh access for node julia on HMC. The procedure will allow node julia to run HMC commands without providing a password.  Enabling the remote command execution on HMC. In the management area of the HMC main panel, select HMC Management → HMC Configura

Summary of the content on the page No. 14

HMC Configuration. In the right panel select Customize Network Setting, press the LAN Adapters tab, choose the interface used for remote access and press Details. In the new window select the Firewall tab. Check that the ssh port is allowed for access (see Figure 6). Figure 6 Firewall settings for eth1 interface  Install the ssh client on the AIX node: The packages can be found on the AIX 5L Bonus Pack CD. To get the latest release packages, access the following URL: http://sourceforge.ne

Summary of the content on the page No. 15

openssh.msg.en_US 3.8.0.5302 C F Open Secure Shell Messages -  Log in the user account used for remote access to the HMC. Generate the ssh keys using the ssh-keygen command. In Example 2, we used the root user account and specified the RSA algorithm for encryption. The security keys are saved in the /.ssh directory. Example 2 ssh-keygen output root@julia/>ssh-keygen -t rsa Generating public/private rsa key pair. Enter file in which to save the key (//.ssh/id_rsa): Enter p

Summary of the content on the page No. 16

Now, we force node nils to fail and prepare to start the takeover scenario (see Figure 7). P550 – 2 CPU - 8GB P550 – 4 CPU – 8 GB 1 nils (production) julia (production) 2 CPUs (dedicated) 2 CPU (shared) takeover 7 GB 7 GB oli (production) 1 CPU (dedicated) 5120 MB nicole_vio (VIO server) 0.8 CPU (shared) 1024 MB CoD activation DLPAR operations 2 HMC 1 HMC 2 1 - Failover to node julia 2 - Node julia remotely activates CoD and performs DLPAR operations via HMC Figure 7 CoD and dynamic

Summary of the content on the page No. 17

Figure 8 Activating the On/Off CoD  Activating On/Off CoD using the command line interface. Example 4 shows how node julia activates 2 CPUs and 8 GB of RAM for 3 days by running via ssh the command chcod on the HMC. Example 4 Activating CoD using command line interface CPU: root@julia/.ssh>ssh hscroot@hmctot184 "chcod -m p550_itso1 -o a -c onoff -r proc -q 2 -d 3" Memory: root@julia/.ssh>ssh hscroot@hmctot184 "chcod -m p550_itso1 -o a -c onoff -r mem -q 8192 -d 3"  Perform the

Summary of the content on the page No. 18

Note: If you use reserve CoD instead of ON/OFF CoD to temporarily activate processors, you can assign the CPUs to shared partitions only. In order for node julia to operate with the same resources as node nils had, we have to add 1.8 processing units and 6.5 GB memory to this node.  Allocation of processor units. – Using the graphical user interface. In the Server and Partition panel on HMC, right-click on partition julia and select Dynamic Logical Partitioning → Processor Resources → Add. I

Summary of the content on the page No. 19

Example 5 Perform the CPU addition from the command line root@julia/>lsdev -Cc processor proc0 Available 00-00 Processor root@julia/>ssh hscroot@hmctot184 lshwres -r proc -m p550_itso1 --level\ \ >lpar --filter "lpar_names=julia" -F lpar_name:curr_proc_units:curr_procs\ \ >--header lpar_name:curr_proc_units:curr_procs julia:0.2:1 root@julia/>ssh hscroot@hmctot184 chhwres -m p550_itso1 -o a -p julia \ \ -r proc --procunits 1.8 --procs 1 root@julia/>lsdev -Cc processor proc0 Available 00-00

Summary of the content on the page No. 20

Figure 10 Add memory to partition – Using the command line. Example 6 shows how to allocate 6 GB of memory to partition julia. Example 6 Memory allocation using command line interface root@julia/>lsattr -El mem0 goodsize 1024 Amount of usable physical memory in Mbytes False size 1024 Total amount of physical memory in Mbytes False root@julia/>ssh hscroot@hmctot184 lshwres -r mem -m p550_itso1 --level \ \ >lpar --filter "lpar_names=julia" -F lpar_name:curr_mem --header lpar_name:curr_mem


Alternative user manuals
# User manual Category Download
1 IBM User manual Computer Drive 0
2 IBM 8305 User manual Computer Hardware 7
3 IBM 6337 User manual Computer Hardware 0
4 IBM 8313 User manual Computer Hardware 1
5 IBM HOTR User manual Computer Hardware 0
6 IBM 6342 User manual Computer Hardware 1
7 IBM 2256 User manual Computer Hardware 2
8 IBM 6336 User manual Computer Hardware 0
9 IBM 2292 User manual Computer Hardware 2
10 IBM SBC-658 User manual Computer Hardware 0
11 IBM 8308 User manual Computer Hardware 2
12 IBM 6339 User manual Computer Hardware 5
13 IBM THINKCENTER 8128 User manual Computer Hardware 0
14 IBM 6346 User manual Computer Hardware 0
15 IBM 8312 User manual Computer Hardware 0
16 Sony MSAKIT-PC4A User manual Computer Hardware 2
17 Sony MRW62E-S1 2694866142 User manual Computer Hardware 5
18 Philips MATCH LINE 9596 User manual Computer Hardware 17
19 Sony 64GB SDHC Class 10 Memory Card Readers SF32UY User manual Computer Hardware 1
20 Philips PSC702 User manual Computer Hardware 1