Whynter ARC-08WB user manual

User manual for the device Whynter ARC-08WB

Device: Whynter ARC-08WB
Category: Air Conditioner
Manufacturer: Whynter
Size: 1.01 MB
Added : 6/10/2014
Number of pages: 21
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Whynter ARC-08WB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Whynter ARC-08WB.

For your convenience

If looking through the Whynter ARC-08WB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Whynter ARC-08WB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Whynter ARC-08WB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Whynter ARC-08WB User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Whynter ARC-08WB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Whynter ARC-08WB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



WHYNTER ECO-FRIENDLY 8,000 BTU PORTABLE AIR CONDITIONER




MODEL# : ARC-08WB



Instruction Manual
Congratulations on your new WHYNTER product. Please read this Instruction Manual carefully
before using this product to ensure proper operation. Keep this manual in a safe place for future
reference.

Summary of the content on the page No. 2

TABLE OF CONTENTS INTRODUCTION / DISPOSAL INFORMATION 3 SAFETY PRECAUTIONS / OPERATING CONDITION 4 - 5 IDENTIFICATION OF ACCESSORIES 6 IDENTIFICATION OF PARTS 7 CONTROL PANEL 8 INSTALLATION INSTRUCTIONS 9 - 12 OPERATION INSTRUCTIONS 13 - 14 WATER DRAINAGE 15 REMOTE CONTROL 16 CARE AND MAINTENANCE 17 TECHNICAL DATA 18 TROUBLESHOOTING 19 - 20 WARRANTY INFORMATION 21 2| P a g e

Summary of the content on the page No. 3

Thank you for choosing the Whynter portable air conditioner. Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference. DISPOSAL This sy

Summary of the content on the page No. 4

Your safety and the safety of others are very important to us. To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions. SAFETY PRECAUTIONS Before the appliance is used, it must be properly positioned and installed as detailed in this manual.  Do not under any circumstances cut or remove the third (ground) prong from the power cord  Make sure this unit is connected to a correctly grounded power supply outlet. Do

Summary of the content on the page No. 5

 Do not allow children to climb, stand or hang on the appliance. The air conditioner could tip over and get damaged and/or seriously injure somebody  Keep fingers out of the air intakes and air outlets  The appliance is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions  When positioning or moving the appliance, ensure it is not turned

Summary of the content on the page No. 6

IDENTIFICATION OF ACCESSORIES IMAGE ACCESSORY NAME QUANTITY Exhaust hose, Sliding Round Adaptor 1 set and Flat Mouth Adaptor Window sliders and Clear plastic plug (plug is in the upper corner of the 1 set plastic bag that holds the user manual) Foam seal 3 pcs Remote control & Batteries 1 set Drain hose 1 pc Activated Carbon filter 1 pc 6| P a g e

Summary of the content on the page No. 7

IDENTIFICATION OF PARTS Front 1. Control Panel 2. Front Air Vent / Louvers 3. Handles 4. Remote Signal receptor 5. Panel Rear 6. Upper air filter 7. Air outlet (hot air exhaust) 8. Casters 9. Upper air intake 10. Upper drain port 11. Lower air intake (Compressor) 12. Lower air filter 13. Lower drain port 7| P a g e

Summary of the content on the page No. 8

OPERATING YOUR AIR CONDITIONER Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control. CONTROL PANEL 1. MODE 5. TIMER Controls the 4 function modes: COOL, DRY Turns the timer function on and off. To cancel the (DEHUMIDIFY), FAN, and AUTO timer, press

Summary of the content on the page No. 9

INSTALLATION INSTRUCTIONS The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects. Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air- conditioning. Cool or Auto Mode Install Hose Dehumidify or Fan Mode Remove Hose

Summary of the content on the page No. 10

Window kit Installation When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dry or fan only mode, no exhaust is required. Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary for you to modify the installation procedures for your window. Please refer to Fig. 6 & Fig. 7 for minimum and maximum window openings. NOT

Summary of the content on the page No. 11

Window kit Installation in a double-hung window 1. Open window or sliding door for approximately 5” 2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the window. Fig.10. 3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. Fig. 11. 4. Close the window on the window slide bars. For long term installation, you may screw

Summary of the content on the page No. 12

Window kit Installation in a sliding door/ window 1. Open window or sliding door for approximately 5” 2. Cut the foam seal (adhesive type) to the proper length and attach it to the bottom of the door / window. See Fig.14. 3. Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window. See Fig. 15. 4. Close the door/ window on the window slide bars. For long term inst

Summary of the content on the page No. 13

OPERATION INSTRUCTIONS BEFORE USING YOUR APPLIANCE  Remove the exterior and interior packing  Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation SWITCHING ON/OFF THE AIR CONDITIONER  The appliance can be switched ON or OFF by pressing the On-Off button on the control panel or the On/Off button on the remote control COOLING

Summary of the content on the page No. 14

TIMER (DELAYED SWITCH ON / OFF) FUNCTION  This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled SETTING SW ITCH OFF TIMER With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set the desired time delay OFF hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour in

Summary of the content on the page No. 15

WATER DRAINAGE When the water level of the bottom tray reaches maximum level, the unit will beep 8 times and the digital display will show P1 symbol. Also, the cooling or dehumidifying function will stop and the fan only function will start. Continuous drainage In COOL or DRY modes, remove the upper drain plug from the back of the unit and install the drain water hose (5/8 universal female mender) with ¾” hose (can be purchased locally). If this part is unavai

Summary of the content on the page No. 16

REMOTE CONTROL The portable air conditioner can be switched on by the remote control. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet. NOTE:  Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferen

Summary of the content on the page No. 17

CARE AND MAINTENANCE IMPORTANT:  Switch off the air conditioner and disconnect the plug from the power outlet  Drain water by removing the drain plug  Always transport the air conditioner in an upright position only CLEANING THE AIR FILTERS  To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the air filters at least once every two weeks  This unit has two pre-filters; the upper and the lower filte

Summary of the content on the page No. 18

TECHNICAL DATA Cooling capacity 8,000 BTU cooling capacity Power supply 115 V / 60Hz Maximum power input 910W Maximum input 8.2 Amps Dehumidifying capacity 45.6 Pts/day Thermostat 62° - 88°F (17°C - 30°C) Refrigerant R410A Air flow (max.) 270m3/h /159CFM Fan speeds 3 (LOW and HIGH or AUTO) Exhaust hose length 59” / 5’ Unit Dimensions 13.25" D x 13.75" W x 29" H Unit W eight 47.5 lbs 18 | P a g e

Summary of the content on the page No. 19

TROUBLESHOOTING Problem Possible Causes Solutions The portable air  Power failure / outage  Restore the power supply conditioner does not  The automatic switch, line  Flip the switch / change the fuse / turn the turn on fuse, or breaker has been breaker back on. Also note that you may have tripped too many appliances drawing power on one circuit, you may need to move the other appliances to another circuit  The power supply voltage is  Move the unit onto another circuit with th

Summary of the content on the page No. 20

Problem Possible Causes Solutions The unit has worked for  Windows or doors are open  Close all windows and doors a long time, but the room is not cold enough  There are too many people  You may need additional cooling or in the room another air conditioner  There is direct sunshine into  Close curtains or blinds and try to the room minimize the amount of direct sunlight into the room  The room is a kitchen or with many heat-producing  You may need additional cooling or


Alternative user manuals
# User manual Category Download
1 Whynter ARC-12H User manual Air Conditioner 2
2 Whynter ARC-12SDH User manual Air Conditioner 18
3 Whynter ARC-14S User manual Air Conditioner 21
4 Whynter SNO ARC-13W/S User manual Air Conditioner 3
5 Whynter ECO-FRIENDLY ARC-10WB User manual Air Conditioner 5
6 Whynter ARC-143MX User manual Air Conditioner 2
7 Whynter ARC-12SD User manual Air Conditioner 5
8 Whynter ARC-12S User manual Air Conditioner 4
9 Whynter ARC-13PG User manual Air Conditioner 0
10 Whynter ARC-131GD User manual Air Conditioner 8
11 Whynter ARC-14S User manual Air Conditioner 8
12 Whynter ARC-14SH User manual Air Conditioner 34
13 Whynter ARC-12D User manual Air Conditioner 2
14 Sony SU-PW2 User manual Air Conditioner 12
15 Sony CV-P12PX User manual Air Conditioner 3
16 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31
17 Sony VGN-BX500 User manual Air Conditioner 1
18 Philips 190S5 User manual Air Conditioner 21