York YZH024 THRU 060 user manual

User manual for the device York YZH024 THRU 060

Device: York YZH024 THRU 060
Category: Air Conditioner
Manufacturer: York
Size: 0.42 MB
Added : 5/22/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for York YZH024 THRU 060. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with York YZH024 THRU 060.

For your convenience

If looking through the York YZH024 THRU 060 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual York YZH024 THRU 060 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual York YZH024 THRU 060 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
York YZH024 THRU 060 User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual York YZH024 THRU 060 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to York YZH024 THRU 060. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

345094-YTG-D-0108
DESCRIPTION
The YZHSeries unit is the outdoor part of a versatile heat pump
system. It is designed to be custom matched with one of our
complete line of evaporator sections, each designed to serve a
specific function. Matching air handlers are available for upflow,
downflow, and horizontal left or right application to provide a
complete system. Electric heaters are available if required. Add-
on coils are available for use with upflow, downflow, or horizontal
furnaces. Field in

Summary of the content on the page No. 2

345094-YTG-D-0108 Physical and Electrical Data MODEL YZH02411 YZH03611 YZH04811 YZH06011 Unit Supply Voltage 208-230V, 1 φ, 60Hz 1 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 18.2 23.6 29.2 34.8 2 30 40 50 60 Max. Overcurrent Device Amps 3 20 25 30 35 Min. Overcurrent Device Amps Multi-stage Compressor Yes Yes Yes Yes Compressor Type Scroll Scroll Scroll Scroll Rated Load 12.3 16.6 21.1 25.6 Compressor Amps Locked Rotor 52 82 96 118 Crankcase Heater No No No No Fan Motor Amps Ra

Summary of the content on the page No. 3

345094-YTG-D-0108 Additional R-410A Charge / TXV Size for Various Matched Systems Outdoor Unit YZH02411 YZH03611 YZH04811 YZH06011 1 1TVM903 1TVM906 1TVM906 1TMV906 Approved System Thermal Expansion Valve Factory R-410A Charge, lbs-oz 14 - 12 12 - 7 12 - 13 14 - 8 2 3 Indoor Coil TXV Kit - Additional Charge, Oz FC/MC/PC43B 00–– FC/MC/PC43C –0–– FC/MC/PC48C –00– FC/MC/PC48D +40 0 – FC/PC60C +8+4+40 FC/MC/PC60D +8+4+40 FC/MC62D –+8+8+4 HC42 –0–– AV36 00–– AV/SV48 –+40– AV/SV60 ––+40 FOOTNOTES:

Summary of the content on the page No. 4

345094-YTG-D-0108 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING 1 UNIT COIL NET MBH RATED MODEL MODEL MODEL W STAGE SEER EER CFM TOTAL SENSIBLE 18 SEER HP WITH MV - VARIABLE SPEED 1 645 18.2 13.5 14.00 MV12B 17 FC/MC43B 16.40 2 835 23.6 18.8 13.60 1 645 18.5 14.0 14.50 YZH02411 MV12D 24 FC/MC48D 17.00 2 835 24.0 19.5 14.00 1 645 18.5 14.0 14.50 MV12D 24 FC/MC60D 17.00 2 835 24.0 19.5 14.00 1 775 24.8 18.2 14.20 MV16C 21 FC/MC43C 17.10 2 1200 35.4 26.6 13.10 1 775 25.

Summary of the content on the page No. 5

345094-YTG-D-0108 COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL STAGE SEER EER CFM TOTAL SENSIBLE 1 560 18.0 12.9 14.10 YZH02411 P(C,V)9*B12 FC/MC/PC43B 17 16.6O 2 820 23.6 18.9 13.30 1 750 24.6 18.1 14.20 P(C,V)8*B16 FC/MC/PC43B 17 17.0O 2 1200 35.2 26.4 13.40 1 640 23.8 16.6 14.05 P(C,V)8*C16 FC/MC/PC43C 21 16.9O 2 1200 35.4 26.6 13.45 1 780 24.6 18.3 14.15 P(C,V)8*C20 FC/MC/PC43C 21 17.0O 2 1200 35.2 26

Summary of the content on the page No. 6

345094-YTG-D-0108 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL STAGE SEER EER CFM TOTAL SENSIBLE 1 880 33.0 23.4 13.30 P(C,V)8*C16 FC/MC/PC48C 21 16.3O 2 1500 46.0 34.6 11.70 1 1030 33.0 25.0 13.40 P(C,V)8*C20 FC/MC/PC48C 21 16.4O 2 1610 46.5 35.4 11.80 1 1090 34.0 26.0 13.86 P(C,V)9*C16 FC/MC/PC48C 21 16.9O 2 1600 46.0 35.2 11.60 1 1010 33.0 24.6 13.20 P(C,V)9*C20 FC/MC/PC48C 21 16.2O 2 1580

Summary of the content on the page No. 7

345094-YTG-D-0108 HEATING CAPACITY - With Air Handler HEATING 1 AIR HANDLER COIL UNIT MODEL W NET MBH RATED MODEL MODEL STAGE HSPF COP @ 47 CFM 47 OD 17 OD 18 SEER HP WITH MV - VARIABLE SPEED 1 645 19.3 - - 4.0 MV12B FC/MC43B 17 2 835 24.0 17.0 9.6 4.0 2 645 24.0 15.2 9.3 3.4 1 645 19.3 - - 4.0 YZH02411 MV12D FC/MC48D 24 2 835 24.0 16.8 9.8 4.0 2 645 24.0 15.0 9.5 3.4 1 645 19.3 - - 4.0 MV12D FC/MC60D 24 2 835 24.0 16.8 9.8 4.0 2 645 24.0 15.0 9.5 3.4 1 775 26.4 - - 4.2 MV16C FC/MC43C

Summary of the content on the page No. 8

345094-YTG-D-0108 \ HEATING CAPACITY - With Variable Speed Furnaces HEATING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED COP @ FURNACE MODEL MODEL STAGE HSPF CFM 47 47 OD 17 OD 1 560 19.1 - - 3.80 YZH02411 P(C,V)9*B12 FC/MC/PC43B 17 2 820 24.2 17.1 9.6 3.90 2 560 23.8 15.0 9.3 3.20 1 750 26.4 - - 4.00 P(C,V)8*B16 FC/MC/PC43B 17 2 1200 36.0 26.6 9.35 4.20 2 750 36.0 24.6 9 3.20 1 640 26.0 - - 3.80 P(C,V)8*C16 FC/MC/PC43C 21 2 1200 36.0 26.4 9.35 4.20 2 640 36.0 24.4 9 3.00 1 780 26.

Summary of the content on the page No. 9

345094-YTG-D-0108 HEATING CAPACITY - With Variable Speed Furnaces (Continued) HEATING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED COP @ FURNACE MODEL MODEL STAGE HSPF CFM 47 47 OD 17 OD 1 780 26.4 - - 4.00 P(C,V)8*C20 FC/MC62D 24 2 1200 36.0 26.2 9.55 4.20 2 780 36.0 23.8 9.35 3.20 1 790 26.4 - - 4.00 P(C,V)9*C20 FC/MC62D 24 2 1195 36.0 26.0 9.55 4.20 2 790 36.0 24.0 9.35 3.40 1 775 26.4 - - 4.00 P(C,V)9*D20 FC/MC62D 24 2 1220 36.0 26.0 10 4.40 2 775 36.0 23.8 9.8 3.20 1 640 26.0

Summary of the content on the page No. 10

345094-YTG-D-0108 HEATING CAPACITY - With Variable Speed Furnaces (Continued) HEATING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED COP @ FURNACE MODEL MODEL STAGE HSPF CFM 47 47 OD 17 OD 1 985 36.0 - - 3.80 P(C,V)9*D20 FC/MC/PC60D 24 2 1560 48.0 32.6 9.8 4.00 2 985 39.0 25.6 9.5 3.20 1 1030 36.0 - - 3.80 P(C,V)8*C20 FC/MC62D 24 2 1610 48.0 32.8 9.8 4.00 2 1030 38.5 25.2 9.5 3.20 YZH04811 1 1010 36.0 - - 3.80 P(C,V)9*C20 FC/MC62D 24 2 1580 48.0 32.6 9.3 3.80 2 1010 38.0 25.0 9 3.00

Summary of the content on the page No. 11

345094-YTG-D-0108 ACCESSORIES* SOUND POWER RATINGS* (dBA) TXV Kits - 1TVM9 series thermal expansion valves precisely UNIT MODEL meter refrigerant for optimum performance. Cooling Heating 024 71 72 Bonnet Sensor (2SB13700124) - The bonnet sensor is used to sense plenum temperature, and is optional with a gas or oil 036 72 73 back-up heat source. Compatible only with 13 SEER and higher 048 72 73 heat pumps. 060 73 74 Dehumidistat (2HU16700124) - Provides increased dehumidi- * Rated in accordance w

Summary of the content on the page No. 12

345094-YTG-D-0108 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH02411 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D ID CFM 600 650 700 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 19.7 20.0 19.9 22.0 23.6 19.7 20.0 19.9 22.0 23.6 19.7 20.0 19.9 22.0 23.6 65 S.C. 19.7 19.2 15.7 15.8 13.0 19.7 19.2 15.7 15.8 13.0 19.7 19.2 15.7 15.8 13.0 K.W. 0.8 0.8 0.8 0.8 0.

Summary of the content on the page No. 13

345094-YTG-D-0108 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH02411 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D ID CFM 740 840 940 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 24.9 26.6 26.4 28.8 30.9 25.8 27.2 26.9 29.3 31.6 26.7 27.8 27.4 29.8 32.2 65 S.C. 24.9 23.2 19.7 19.3 16.3 25.8 24.9 20.8 20.5 16.8 26.7 26.6 21.8 21.6 17.4 K.W. 1.2 1.2 1.2 1.2 1

Summary of the content on the page No. 14

345094-YTG-D-0108 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH03611 INDOOR COIL MODEL NO. FC/MC62D + MV12D ID CFM 796 846 896 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 26.3 27.5 27.3 30.5 33.5 26.9 28.0 27.7 30.9 34.1 27.4 28.4 28.1 31.3 34.7 65 S.C. 26.3 23.9 20.3 20.4 16.7 26.9 25.0 20.9 21.0 17.1 27.4 26.1 21.6 21.6 17.5 K.W. 1.0 1.0 1.0 1.0 1.1 1

Summary of the content on the page No. 15

345094-YTG-D-0108 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH03611 INDOOR COIL MODEL NO. FC/MC62D + MV12D ID CFM 1148 1248 1348 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 38.4 39.7 40.2 43.7 47.8 39.4 40.6 40.8 44.4 48.5 40.5 41.5 41.3 45.2 49.1 65 S.C. 38.4 35.1 30.0 29.8 24.1 39.4 37.0 31.1 30.9 24.9 40.5 38.8 32.2 32.0 25.7 K.W. 1.7 1.7 1.7 1.8 1

Summary of the content on the page No. 16

345094-YTG-D-0108 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH04811 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1000 1050 1100 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 33.8 35.9 35.8 39.4 43.5 34.4 36.3 36.2 39.9 43.9 35.0 36.8 36.6 40.4 44.4 65 S.C. 33.8 31.5 26.6 26.7 22.2 34.4 32.4 27.2 27.4 22.5 35.0 33.3 27.8 28.0 22.8 K.W. 1.5 1.5 1.5 1.5 1.

Summary of the content on the page No. 17

345094-YTG-D-0108 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH04811 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1470 1570 1670 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 47.6 49.8 49.6 54.3 58.9 48.5 50.1 50.2 54.9 59.2 49.5 50.5 50.8 55.5 59.5 65 S.C. 47.6 44.6 37.5 37.5 30.0 48.5 46.3 38.7 38.5 30.5 49.5 48.0 39.8 39.6 31.0 K.W. 2.3 2.3 2.3 2.4 2

Summary of the content on the page No. 18

345094-YTG-D-0108 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH06011 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1125 1175 1225 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 40.8 44.0 43.6 48.6 53.8 41.5 44.4 44.1 49.2 54.3 42.3 44.8 44.7 49.8 54.9 65 S.C. 40.8 37.2 31.3 31.5 25.9 41.5 38.0 32.0 32.1 26.3 42.3 38.9 32.6 32.7 26.8 K.W. 2.0 2.0 2.0 2.0 2.

Summary of the content on the page No. 19

345094-YTG-D-0108 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH06011 INDOOR COIL MODEL NO. FC/MC62D + MV20D ID CFM 1718 1818 1918 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 57.5 60.6 60.7 65.4 73.0 58.5 61.3 61.4 66.1 73.4 59.5 62.0 62.0 66.8 73.8 65 S.C. 57.5 53.3 45.1 44.5 37.1 58.5 54.8 46.3 45.7 37.5 59.5 56.4 47.5 46.9 38.0 K.W. 2.8 2.9 2.9 3.0 3

Summary of the content on the page No. 20

345094-YTG-D-0108 HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZH02411 INDOOR COIL MODEL NO. FC/MC/PC48D + MV12D AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 600 650 700 OUTDOOR INDOOR MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P. UNIT COIL 60 24.2 1.4 5.2 24.4 1.3 5.4 24.5 1.3 5.6 60 70 23.9 1.5 4.6 24.0 1.5 4.7 24.1 1.4 4.9 80 23.5 1.7 4.1 23.5 1.6 4.2 23.6 1.6 4.3 60 19.8 1.3 4.5 19.8 1.2 4.6 19.8 1.2 4.8 47 70 19.3 1.4 4.0 19.3 1.4 4.1 19.4 1.4 4.2 80


Alternative user manuals
# User manual Category Download
1 York 036-21103-003 User manual Air Conditioner 1342
2 York 12 SEER H*RC036S User manual Air Conditioner 255
3 York 12 SEER H*AH024 - 60 User manual Air Conditioner 104
4 York 131001-YUM-A-1205 User manual Air Conditioner 80
5 York 12 SEER H*RC018 THRU 060 User manual Air Conditioner 72
6 York 14 Series User manual Air Conditioner 120
7 York 13 Series User manual Air Conditioner 67
8 York 13 User manual Air Conditioner 63
9 York 13 SEER - R410A CZB018 THRU 060 User manual Air Conditioner 151
10 York 10 SEER 50HZ R22 User manual Air Conditioner 83
11 York 14 User manual Air Conditioner 44
12 York 14.5 SEER TCGF60 User manual Air Conditioner 25
13 York 14.5 SEER TCGF24 User manual Air Conditioner 29
14 York 251934-YTG-J-0910 User manual Air Conditioner 32
15 York 36 User manual Air Conditioner 78
16 Sony SU-PW2 User manual Air Conditioner 12
17 Sony CV-P12PX User manual Air Conditioner 3
18 Sony MULTI CHANNEL AV RECEIVER STR-DG710 User manual Air Conditioner 31