RTI ID900 user manual

User manual for the device RTI ID900

Device: RTI ID900
Category: Refrigerator
Manufacturer: RTI
Size: 0.1 MB
Added : 2/7/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for RTI ID900. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with RTI ID900.

For your convenience

If looking through the RTI ID900 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual RTI ID900 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual RTI ID900 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
RTI ID900 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual RTI ID900 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to RTI ID900. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




OPERATION MANUAL

ID900

Portable Refrigerant Identifier

WARNING
Liquid Samples will Damage Unit
Do not operate if filter has red flecks.
Replace filter every 3 months
or after every 25 uses.
Always have a spare
Call RTI Technologies to order




4075 East Market Street


York, Pennsylvania 17402

Phone: 800-468-2321 or 717-840-0678

Fax: 717-755-8304

E-mail: rti@rtitech.com

Web-site: www.rtitech.com



Manual No. 035-80979-00

Summary of the content on the page No. 2

Table of Contents I. Cautions and Warnings 3 II. Functional Description 4 III. Hardware Description 5 A. Instrument 5 1. Case 5 2. Hanger 5 3. Sample Filter 5 4. Control Panel 5 5. Air Intake Port 5 6. Sample Exhaust Port 5 7. Sample Inlet Port 5 8. Air Detection Sensor 5 9. Control Circuit Board 5 10. Purge Pump 5 11. Power Connector 5 B. Sample Hoses 6 1. R12 Sample Hose 6 2. R134a Sample Hose 6 C. Po

Summary of the content on the page No. 3

I. Cautions and Warnings A. Cautions Never use any sample hose other than those approved for use with the ID900. The use of other hose types may introduce errors and excessive refrigerant loss. Always verify that the refrigerant source to be tested will not emit oil or liquid refrigerant before connecting the ID900 sample hose. Never connect the ID900 to any refrigerant source that exceeds 300-psi pressure. Do not utilize the coupling supplied on the ID900 R134a sample hose for an

Summary of the content on the page No. 4

II. Functional Description Contamination of refrigerant in air conditioning systems or storage cylinders can lead to component corrosion, component destruction, elevated system head pressure and system failures when utilized by unsuspecting technicians. The ability of a technician to determine refrigerant type and purity is severely hampered by the presence of air when attempting to utilize pressure- temperature relationships. The development of substitute refrigerants further complicates

Summary of the content on the page No. 5

11. Power 11. Power Hanger Connector Connector Serial Number Location 9.Control Circuit Board 4. Control Panel Sensor Housing Sample filter exit Air Intake 6. Sample exhaust tube Port port 8.Air Detection Sensor InletPressure 1. Case Regulator 10. Purge 3. Sample filter Housing screws; Pump 8 total Sample filter inlet valve Sample Inlet Port View with Cover Removed Front View Rear View III. Hardware Description A. Instrument: The instrument ho

Summary of the content on the page No. 6

B. Sample Hoses 1. R12 Sample Hose: is a 6-foot hose consisting of a nylon inner tube surrounded by a polyurethane outer tube. The hose contains the instrument connection fitting on one end and a ¼” SAE female flare nut on the other end. This hose is to be utilized when sampling from R12 vehicle systems or storage cylinders. 2. R134a Sample Hose: is a 6-foot hose consisting of a nylon inner tube surrounded by a polyurethane outer tube. The hose contains the instrument connection fitting o

Summary of the content on the page No. 7

IV. Operation Procedure A. Pre-Operative Inspection 1. Inspect the outside diameter of the white element contained within the sample filter for any signs of red spots. The appearance of red spots anywhere on the outside diameter of the element indicates that the filter requires replacement to avoid fouling of the instrument. 2. Select the R12 or R134a sample hose as dictated by the application. Inspect the hose for cracks, signs of wear, obstruction or fouling. DO NOT use any hose that

Summary of the content on the page No. 8

5. When prompted by the instrument, connect the free end of the sample hose to the vehicle air conditioning system or refrigerant storage cylinder port and press the “A” pushbutton. Sample gas will immediately begin to flow into the instrument. The instrument will require approximately 30 seconds to complete the sample gas analysis. 6. When the analysis has completed immediately disconnect the sample hose from the refrigerant source. Note: The instrument contains no automatic shut-off and

Summary of the content on the page No. 9

V. Maintenance A. Error Codes and Corrective Actions The instrument is supplied with self-diagnostic software to aid the user in the determination of problems. The software will supply error codes that will direct the user towards specific corrective actions in the event of system failure. ERR.1: Signifies unstable infrared readings due to inconsistent sample gas supply or interference from strong electrical fields. Corrective Actions: 1. If the error code occurs during a sample cycl

Summary of the content on the page No. 10

Warning: Should it be determined that the air detection calibration failure has been caused by the presence of oxygen depleting compounds in the surrounding atmosphere the use MUST take immediate action to rid the area of such compounds or provide adequate ventilation to prevent such accumulation. The accumulation of oxygen depleting compounds in the surrounding atmosphere will present a human health risk and hazard. 3. To clear the error code power down the instrument. The error code will

Summary of the content on the page No. 11

c) When the hose is completely dry inspect the hose for signs of wear as described above. 3. Air Detection Sensor Replacement Inspection Frequency: The instrument will inform the user of possible air detection replacement requirements with the error code Replace Air Sensor. Air Detection Sensor Replacement Procedure: a) Refer to the error code corrective actions and try each suggested action. If the instrument still indicates the error code then the air detection sensor will require re

Summary of the content on the page No. 12

VI. Specifications Sample Parameters: Vapor only, oil and liquid free, 300 psig (2 MPa) Maximum Detected Compounds: R12, R134a, Air and unknown compounds Sensor Technologies: Non-Dispersive Infrared and Chemical Fuel Cell Refrigerant Sample Size: 0.12 ounces (3.5 grams) per typical sample – weight of vapor loss Power (Standard): Powered by vehicle battery through clip-on adapter harness (10 to 14 VDC). Power (Optional): Powered by line power through plug-in wall ad


Alternative user manuals
# User manual Category Download
1 2JANE Surround Sound System HTS-GS1 User manual Refrigerator 4
2 3Com Phaser 7750 User manual Refrigerator 1
3 3Com iQ 10 User manual Refrigerator 0
4 3Com PowerDual iQ 10 iQ 10C User manual Refrigerator 1
5 3Com PowerDual iQ 10 iQ 10P User manual Refrigerator 2
6 3Com Dell D-Family Battery Charger CHRG01L User manual Refrigerator 0
7 3Com PowerDual iQ 10 iQ 10PC User manual Refrigerator 0
8 3Com Preface Firmware Version 1.07 VFD-D D User manual Refrigerator 0
9 3D Connexion Infinity Systems Interlude IL120s User manual Refrigerator 1
10 3D Connexion Cisco Catalyst Blade Switch 3040 for FSC Hardware OL-10694-01 User manual Refrigerator 0
11 3D Connexion 42" SNOW THROWER LST42B User manual Refrigerator 0
12 3D Connexion Cisco SCA BB SNMP Real Time Monitoring OL-12491-01 User manual Refrigerator 0
13 3D Connexion Primergy ServerView Suite TivoII User manual Refrigerator 0
14 3D Innovations The Xerox DocuPrint Color Laser Printer NC60 User manual Refrigerator 0
15 3G Green Green Globe Automatic Transfer Switch ZTS Series User manual Refrigerator 0