Manual do usuário Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase )

Manual para o dispositivo Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase )

Dispositivo: Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase )
Categoria: Aquecedor de água
Fabricante: Thermo Products
Tamanho: 0.87 MB
Data de adição: 5/22/2013
Número de páginas: 24
Imprimir o manual

Baixar

Como usar?

Nosso objetivo é fornecer-lhe o mais rapidamente possível o acesso ao conteúdo contido no manual de instruções para Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ). Usando a pré-visualização online, você pode visualizar rapidamente o índice e ir para a página onde você vai encontrar a solução para seu problema com Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ).

Para sua conveniência

Se a consulta dos manuais Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ) diretamente no site não for conveniente para você, você tem duas soluções possíveis:

  • Visualização em tela cheia - Para visualizar facilmente o manual do usuário (sem baixá-lo para seu computador), você pode usar o modo de tela cheia. Para começar a visualização do manual Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ) no modo de tela cheia, use o botão Tela cheia.
  • Download para seu computador - você também pode baixar o manual Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ) em seu computador e mantê-lo em suas coleções. No entanto, se você não quer perder espaço no seu dispositivo, você sempre pode baixá-lo no futuro a partir de ManualsBase.
Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ) Manual de instruções - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Versão para impressão

Muitas pessoas preferem ler os documentos não na tela, mas na versão impressa. A opção de imprimir o manual também foi fornecida, você pode usá-la clicando na hiperligação acima - Imprimir o manual. Você não precisa imprimir o manual inteiro Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ), apenas as páginas selecionadas. Respeite o papel.

Resumos

Abaixo você encontrará previews do conteúdo contido nas páginas subseqüentes do manual para Thermo Products COMBOMAX Models from 8 kW to 24 kW : 240 Volts ( single phase ). Se você deseja visualizar rapidamente o conteúdo das páginas subseqüentes, você pode usá-los.

Resumos do conteúdo
Resumo do conteúdo contido na página número 3

DESSIN D'ATELIER / GENERAL DIMENSIONS COMBOMAX XX-XX THERMO 2000 inc. Legeng/Légende: Figure 2 1) Boiler Water Supply Connection / Alimentation du chauffage (1" npt F) 2) Boiler Water Return/ Retour du chauffage (1" npt F) 3) Domestic Water inlet / Entrée eau domestique (3/4" Sweat F) 4) Domestic Water outlet/ 7 Sortie eau domestique (3/4" Sweat F) 5) Safety relief valve/ Soupape de sûreté (3/4" npt M.) 6) Temperature and pressure Gage/ Indicateur de Températur

Resumo do conteúdo contido na página número 4

General Safety Precautions ! Be sure to read and understand the entire Use & Care Manual before attempting to install or operate this water heater. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings could cause property damage, bodily injury or death. Should you have any problems understanding the instructions in this manual, STOP, and get help from a qualified installer or technician. Section 2 : Introduction ! WARNING

Resumo do conteúdo contido na página número 5

Section 3 : INSTALLATION WARNING ! 3.3 CLEARANCE The manufacturer’s warranty does not cover The minimum clearances required for proper any damage or defect caused by installation inspection and servicing are as follows: or attachment or use of any special attachment other than those authorized by Table 4: Clearances the manufacturer into, onto, or in Left side 3 inches conjunction with the water heater. The use of Right side 3 inches such unauthorized d

Resumo do conteúdo contido na página número 6

Install shutoff (ball) valves for servicing boiler or any part of the circuit. It is preferable to convenience. Install thermometers on the inlet use a calibrated diaphragm expansion tank. and outlet lines. 3.5.5 Makeup valve Never plug the pressure relief valve to avoid Connecting a makeup valve must be done creating a hazardous situation. according to code. This valve must include a flow-check valve to maintain the minimum 3.5.2 Flow-check valve operating pressure by admitting

Resumo do conteúdo contido na página número 7

reverse-piping method to ensure equal flow through each boiler. Pump flow rate = Boiler output ÷ BWTD ÷ 500 The HOT WATER OUTLET and the COLD • Pump flow rate is expressed in U.S. gallons WATER INLET connections are clearly marked. per minute or GPM. Inlet water connections (COLD WATER INLET) • The Boiler output ( in net BTU per hour) is are to be made to the copper pipe (sweat the maximum amount of heat to be connection) at the bottom of the heater. Outlet transferred throu

Resumo do conteúdo contido na página número 8

cold water supply line between the 3.7 BOILER WIRING MC COMBOMAX unit and flow check valve. The boiler cabling and grounding must conform Contact your installing contractor, water to local codes or, in their absence, to the supplier, local plumbing inspector or plumbing National Electrical Code. supply house for assistance. Power must be provided by a 120/240 volt 3.6.3 Recirculation line (if applicable) (single phase, 60 Hz) circuit, appropriately fused If a recirculation line

Resumo do conteúdo contido na página número 9

3.11 BI-ENERGY SETUP To take advantage of a special domestic electric MC utility rate, your COMBOMAX boiler can be combined with an existing oil or gas-fired furnace. Please contact your utility to make sure your building is eligible and to find out about the new wiring configuration. Please refer to figures 7 and 8 for the set-up required. The CBE-EM bi-energy switching control (available as an option) is especially designed to satisfy utility requirements. The CBE-EM control s

Resumo do conteúdo contido na página número 10

Section 4 : Operation ! SAFETY PRECAUTIONS Before operating this water heater, be sure to 4.3 ADJUSTING THE AQUASTATS read and follow these instructions, as well as Once all air has been bled from the system and the warnings printed in this manual. Failure all components (valves, bleeders, controls) have to do so can result in unsafe operation of the been properly adjusted, the boiler can be put water heater resulting in property damage, into operation. Never operate the boiler be

Resumo do conteúdo contido na página número 11

Adjust the boiler aquastats as required. Please avoid excessive wear and tear on the note that lowering the setting will not have an components due to numerous on-off cycles and immediate effect as the heat stored in the boiler reduce your total heating costs. water must first be consumed. Check the boiler water temperature periodically. Further 4.5 DOMESTIC HOT WATER STARTUP adjustments may be required as the system Maximum boiler water temperature is 190°F. goes through several spac

Resumo do conteúdo contido na página número 12

4.6 ADJUSTING THE MIXING VALVE A thermostatically controlled mixing valve works automatically thanks to the thermostatic element controlling the mix of very hot and cold water as required to provide safe domestic hot water under variable conditions. To adjust the mixing valve setting, carefully open a hot water tap. Protect yourself against the possibility of scalding. Measure the hot water temperature and adjust it with the mixing valve, following the manufacturer’s instructions.

Resumo do conteúdo contido na página número 13

Section 5 : Maintenance Regular boiler maintenance will ensure trouble- flowing out. Upon releasing the lever, the safety free service for many years. It is recommended valve should shut tight. If it does not, it must be that you set up and follow a maintenance replaced by an identical or equivalent model. program. All components fail eventually. The use Never plug a safety valve. of incorrect replacement parts or disregarding safety procedures and warnings during repairs 5.5 SCALE B

Resumo do conteúdo contido na página número 14

! General Safety Precautions Be sure to read and understand the entire Use & Care Manual before attempting to install MC or operate this COMBOMAX unit. Pay particular attention to the following General Safety Precautions. Failure to follow these warnings could cause property damage, bodily injury or death. Should you have any problems understanding the instructions in this manual, STOP, and get help from a qualified installer or technician. To meet commercial hot water needs, the Maxi

Resumo do conteúdo contido na página número 15

THERMO 2000 inc. Réducteur de pression/ COMBOMAX Reducing valve Figure 2 Eau chaude domestique/ Domestic hot water mixed Schéma d'installation général/ Valve de mélange thermostatique/ Thermostatic mixing valve General installation Simple Zone/ Anti retour/ Back flow preventer Valve de sécurité (T&P)/ Single Zone Eau froide domestique/ Safety valve (T&P) Domestic cold water supply Pompe/ à ajouter/ to add Tuyauterie chauffage/ Pump Boiler piping Thermostat Tuyauterie eau domestique/ Domestic

Resumo do conteúdo contido na página número 16

THERMO 2000 inc. Eau chaude domestique/ COMBOMAX Réducteur de pression/ Domestic hot water mixed Reducing valve Figure 3 Schéma d'installation général/ Valve de zonage électrique/ General installation Electric zone valve Système multizones (valves)/ Valve de mélange thermostatique/ Multi-zone system using valves Thermostatic mixing valve Eau froide domestique/ Domestic cold water supply Anti retour/ Valve de sécurité (T&P)/ Tuyauterie chauffage/ Back flow preventer Safety valve (T&P) Boiler pi

Resumo do conteúdo contido na página número 17

THERMO 2000 inc. Eau chaude domestique/ COMBOMAX Réducteur de pression/ Domestic hot water mixed Reducing valve Figure 4 Système primaire/secondaire Valve de zonage électrique/ Primary/Secondary system Electric zone valve Système multizones / Valve de mélange thermostatique/ Multi-zone system Thermostatic mixing valve Anti retour/ Tuyauterie chauffage/ Back flow preventer Boiler piping Valve de sécurité (T&P)/ Safety valve (T&P) Tuyauterie eau domestique/ Pompe/ Domestic piping à ajouter/ to

Resumo do conteúdo contido na página número 18

Diagramme électrique/ Wiri ng diagram Figure 5 COMBOMAX 240V Modèle/Model 6 - 10 KW L1 G L2 N F R5 Voir/see note 2 HL C1 EL1 TH1 R4 CC C1 C1 EL2 TH2 120 V 24 V Légende/ Legend TH5 R1 TH Relais Aquastat R Relay R2 Lampe témoin Élément chauffant/ R3 Pilot light Heating element Fusible R3 Contacteur de puissance R3 C Fuse Power relay T T Cablage en usine/ R4 Chauffage/ Heating Factory wiring HL Haute limite Brun/ Brown Cablage par l'installateur/ B Hi-Limit Wiring by others Noir / Black AB Valve 3

Resumo do conteúdo contido na página número 19

Diagramme électrique/ Wiri ng diagram COMBOMAX 240V : modèle/ model 15 - 24 KW Figure 6 L1 G L2 N F R5 Voir/see note 2 HL C1 EL1 TH1 R4 CC C1 C1 EL2 TH2 120 V EL3 24 V TH3 TH5 C1 C1 R1 EL4 R2 TH4 R3 R3 R3 T T Légende/ Legend R4 Chauffage/ Heating Brun/ Brown TH Relais B Aquastat R Relay Noir / Black AB Valve 3 voies / Bleu / 3-way valve Voir/see note 2 Lampe témoin R6 R1 Blue A Élément chauffant/ Pilot light Heating element Recirculation Fusible Contacteur de puissance R2 C Fuse Power relay Cont

Resumo do conteúdo contido na página número 1

MC
COMBOMAX
Electric boiler with integrated instantaneous water heater

Models from 8 kW to 24 kW :
240 Volts ( single phase )

Use and Care Manual
With installation instructions for the contractor




®
Your COMBOMAX electric boiler has been carefully assembled and factory tested to
provide years of trouble-free service. This manual contains instructions for the safe and
proper installation, operation and maintenance of the boiler, in order to en

Resumo do conteúdo contido na página número 2

Section 1 : Technical specifications Table 1: Boiler specifications 240 Vac (single phase) : Power Nominal load in amps Fuse Wire Model Including Cu Amps Heating Kw BTU/h the elements circulator 1 X 3KW COMBOMAX XX-8 8 27 296 33.3 34.3 2 8 50 1 X 5KW COMBOMAX XX-10 10 34 120 41.6 42.6 2 X 5KW 2 6 60 2 X 3KW COMBOMAX XX-15 15 51 180 62.5 63.5 4 3 100 2 X 4.5KW COMBOMAX XX-18 18 61 416 75.0 76.0 4 X 4.5KW 4 3 100 COMBOMAX XX-20 20 68 240 83.4 84.4 4 X 5KW 4 2 125 COMBOMAX

Resumo do conteúdo contido na página número 20

Figure 7 L1 Diagramme électrique/ Wiri ng diagram N Contrôle Bi-énergy/ Dual control ener gy CBE-EM 120 Vac Transfo 24 Vac Lumière haut tarif/ High tarif light H H V2 Relais/ Relay V3 E2 E2 V2 COMBOMAX Sonde extérieur/ Bi-energie/ Dual energy Outdoor sensor E1 Electrique/ Electric Mazout/ Oil SPDT T2 T Relais chaudière Relais/ Relay mazout/ Oil boiler Relay T1 T Interrupteur DPDT Switch ON-OFF-ON Electrique/ Electric Noir/ Black B V1 Brun/ Brown AB Bleu/ Blue A Cablage en usine/ Mazout/ Oil Fact


Manuais similares
# Manual do usuário Categoria Baixar
1 A.O. Smith 000 Manual de instruções Aquecedor de água 8
2 A.O. Smith 101 Manual de instruções Aquecedor de água 3
3 A.O. Smith 12 40GPC T 100 Manual de instruções Aquecedor de água 4
4 A.O. Smith 104 Series Manual de instruções Aquecedor de água 3
5 A.O. Smith 104 - 110 Manual de instruções Aquecedor de água 6
6 A.O. Smith 105 Series Manual de instruções Aquecedor de água 1
7 A.O. Smith 15 Manual de instruções Aquecedor de água 0
8 A.O. Smith 2100 Manual de instruções Aquecedor de água 0
9 A.O. Smith 1850 Manual de instruções Aquecedor de água 0
10 A.O. Smith 185874-001 Manual de instruções Aquecedor de água 0
11 A.O. Smith 185762-000 Manual de instruções Aquecedor de água 0
12 A.O. Smith 2500 Manual de instruções Aquecedor de água 1
13 A.O. Smith 184769-000 Manual de instruções Aquecedor de água 1
14 A.O. Smith 1300 Manual de instruções Aquecedor de água 0
15 A.O. Smith 197835-001 Manual de instruções Aquecedor de água 0