HERE'S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING MQ POWER CORPORATE OFFICE 18910 Wilmington Ave. 800-421-1244 Carson, CA 90746 FAX: 310-632-2656 Email: mqpower@multiquip.com Internet: www.mqpower.com PARTS DEPARTMENT 800-427-1244 FAX: 800-672-7877 310-537-3700 FAX: 310-637-3284 SERVICE DEPARTMENT 800-835-2551 FAX: 310-638-8046 310-537-3700 TECHNICAL ASSISTANCE 800-835-2551 FAX: 310-638-8046 WARRANTY DEPARTMENT 800-835-2551, EXT. 279 FAX: 310-638-8046 310-537-37
Resumo do conteúdo contido na página número 4
TABLE OF CONTENTS MQ POWER DCA-150SSJU3 MQ POWER DCA-150SSJU3 MQ POWER DCA-150SSJU3 MQ POWER DCA-150SSJU3 MQ POWER DCA-150SSJU3 COMPONENT DRA COMPONENT DRA COMPONENT DRA COMPONENT DRA COMPONENT DRAWINGS WINGS WINGS WINGS WINGS TM TM TM TM TM WHISPER WHISPER WHISPER WHISPER WHISPERW W W W WA A A A ATT TT TT TT TT GENERATOR GENERATOR GENERATOR GENERATOR GENERATOR Generator Assembly .................................................. 72-73 Control Box Assembly .......................................
Resumo do conteúdo contido na página número 5
PARTS ORDERING PROCEDURES When ordering parts, please supply the following information: ❒ ❒❒❒ ❒ Dealer account number ❒ ❒❒❒ ❒ Dealer name and address ❒ ❒❒❒ ❒ Shipping address (if different than billing address) ❒ ❒❒❒ ❒ Return fax number ❒ ❒❒❒ ❒ Applicable model number ❒ ❒❒❒ ❒ Quantity, part number and description of each part ❒ ❒❒❒ ❒ Specify preferred method of shipment: ✓ FedEx or UPS Ground Note: Unless otherwise indicated by customer, all ✓ FedEx or UPS Second Day or Third Day orders are trea
Resumo do conteúdo contido na página número 6
DCA-150SSJU3 — SPECIFICATIONS Table 1. Generator Specifications M3 odel DCA-150SSJU Revolving field, self ventilated, open protected type synchronous Type generator Al rmature ConnectionSg tar with Neutra Zig Za Phase 3e Singl Standby Output1W 65 KVA (132 KW) 95.7 K Prime Output1W 50 KVA (120 KW) 87 K Voltage2V 40V or 480V 240/120 Frequency 60 Hz 1800 rpm Speed Power Factor 00 .8 1. Aux. AC Power Single Phase, 60 Hz Voltage 120 V Output 4.8 KW (2.4 KW x 2) Engine Specifications Model JOHN DEERE
Resumo do conteúdo contido na página número 7
DCA-150SSJU3 — DIMENSIONS (TOP, SIDE AND FRONT) Figure 1. Dimensions TABLE 3. DIMENSIONS Reference Dr imension ft. (mm.)R) eference Lette Dimension ft. (mm. Letter A)3F 5.03 in. (890 mm. 125.98 in. (3,200 mm.) B)3G 5.03 in. (890 mm. 59.06 in. (1,500 mm.) C)3H 9.76 in. (1,010 mm. 47.24 in. (1,200 mm.) D) 39.76 in. (1,010 mm. E) 42.12 in. (1,070 mm. 1 DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 7
Resumo do conteúdo contido na página número 8
DCA-150SSJU3 — SAFETY MESSAGE ALERT SYMBOLS FOR YOUR SAFETY AND THE SAFETY OF OTHERS! HAZARD SYMBOLS Potential hazards associated with the operation of this Safety precautions should be followed at all times when equipment will be referenced with "Hazard Symbols" which operating this equipment. Failure to read and understand the appear throughout this manual, and will be referenced in Safety Messages and Operating Instructions could result in conjunction with Safety "Message Alert Symbols". in
Resumo do conteúdo contido na página número 9
DCA-150SSJU3 — SAFETY MESSAGE ALERT SYMBOLS WARNING - ROTATING PARTS CAUTION - RESPIRATORY HAZARDS NEVER operate equipment with covers, ALWAYS wear approved respiratory or guards removed. Keep fingers, hands, protection. hair and clothing away from all moving parts to prevent injury. CAUTION - ACCIDENTAL STARTING CAUTION - SIGHT AND HEARING HAZARDS ALWAYS place the MPEC control switch ALWAYS wear approved eye and in the OFF/RESET position when the hearing protection. generator is not in use. CA
Resumo do conteúdo contido na página número 10
DCA-150SSJU3 — RULES FOR SAFE OPERATION ■ ALWAYS check the machine for loosened threads or bolts DANGER - READ THIS MANUAL! before starting. Failure to follow instructions in this manual may lead to ■ NEVER operate the generator in an explosive atmosphere serious injury or even DEATH! This equipment is to be or near combustible materials. An explosion or fire could operated by trained and qualified personnel only! This result causing severe bodily harm or even death. equipment is for industrial
Resumo do conteúdo contido na página número 11
DCA-150SSJU3 — RULES FOR SAFE OPERATION Generator Grounding DANGER - ELECTROCUTION HAZARDS To guard against electrical shock and possible damage to During operation of this generator, there the equipment, it is important to provide a good EARTH exists the possibility of electrocution, ground. electrical shock or burn, which can cause Article 250 (Grounding) of the National Electrical Code severe bodily harm or even DEATH! (NEC) provides guide lines for proper grounding and specifies To avoid the
Resumo do conteúdo contido na página número 12
DCA-150SSJU3 — RULES FOR SAFE OPERATION Maintenance Safety Battery Safety ■ The electrical voltage required to operate the generator Use the following guidelines when handling the battery: can cause severe injury or even death through physical ■ The battery contains acids that can contact with live circuits. Turn all circuit breakers OFF cause injury to the eyes and skin. To before performing maintenance on the generator. avoid eye irritation, always wear safety ■ NEVER lubricate components or
Resumo do conteúdo contido na página número 13
DCA-150SSJU3 — RULES FOR SAFE OPERATION Towing & Transporting Safety ■ The maximum speed for highway towing is 55 MPH unless posted otherwise. Recommended off-road towing To reduce the possibility of an accident while transporting is not to exceed 15 MPH or less depending on type of the generator on public roads, always make sure the trailer terrain. that supports the generator and the towing vehicle are in good operating condition and both units are mechanically ■ Place chock blocks underneath
Resumo do conteúdo contido na página número 14
DCA-150SSJU3 — GENERATOR DECALS The DCA-150SSJU3 generator is equipped with a number of safety decals (Figures 2 & 3). These decals are provided for operator safety and maintenance information. The illustration below and on the preceding page show the decals as they appear on the machine. Should any of these decals become unreadable, replacements can be obtained from your dealer. Figure 2. Generator Decals PAGE 14 — DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07)
Resumo do conteúdo contido na página número 15
DCA-150SSJU3 — GENERATOR DECALS Figure 3. Generator Decals (Cont inued) 1 DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 15
Resumo do conteúdo contido na página número 16
DCA-150SSJU3 — INSTALLATION Figure 4. Typical Generator Grounding Application PAGE 16 — DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07)
Resumo do conteúdo contido na página número 17
DCA-150SSJU3 — INSTALLATION Outdoor Installation Generator Grounding Install the generator in a area that is free of debris, To guard against electrical shock and possible damage to bystanders, and overhead obstructions. Make sure the the equipment, it is important to provide a good EARTH generator is on secure level ground so that it cannot slide or ground. shift around. Also install the generator in a manner so that Article 250 (Grounding) of the National Electrical Code (NEC) the exhaust will
Resumo do conteúdo contido na página número 18
DCA-150SSJU3 — GENERAL INFORMATION Open Delta Excitation System DCA-150SSJU3 Whisperwatt™ Series Familiarization The DCA-150SSJU3 generator is equipped with the state of Generator the art "Open-Delta" excitation system. The open delta The MQ Power Model DCA-150SSJU3 is a 120 kW generator system consist of an electrically independent winding wound among stationary windings of the AC output section. (Figure 5) that is designed as a high quality portable (requires a trailer for transport) power sou
Resumo do conteúdo contido na página número 19
DCA-150SSJU3 — MAJOR COMPONENTS Figure 5. Major Components T. able 4 Generator Major Components IN TEM NO. DESCRIPTIO 1y Output Terminal Panel Assembl 2y Output Receptacles Assembl 3y Air Filter Assembl 4y Muffler Assembl 5y Fuel Tank Assembl 6y Engine Assembl 7y Battery Assembl 8y Generator Assembl 9y Circuit Breaker Assembl 1y 0 Diagnostic Display Assembl 1y 1 Generator/Engine Control Panel Assembl 1 DCA-150SSJU3— OPERATION AND PARTS MANUAL — REV. #0 (11/14/07) — PAGE 19
Resumo do conteúdo contido na página número 20
DCA-150SSJU3 — DIAGNOSTIC DISPLAY 3. Right Arrow Button – Press this button to scroll through the screen either moving the parameter selection toward the right or downward. 4. Enter Key Button – Press this button to select the parameter that is highlighted on the screen. 5. Emergency Stop LED – When lit (RED) indicates a major fault has occured. This condition will shudown the generator. 6. Warning LED – When lit (AMBER), indicates a engine parameter has exceeded its limits (minor fault). The ge