ملخص المحتوى في الصفحة رقم 1 
                    
                        INSTALLATION MANUAL
®
For Thermador Professional Cooktops
Models/
Modèles/
Modelos:
PCG30
PCG36
PCG48
MANUEL D'INSTALLATION
®
Des tables de cuisson Thermador Professional
MANUAL DE INSTALACIÓN
®
Para Parrillas de Thermador Professional                                                                                                                                                                                                                                                                         
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Table of Contents Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Before you Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Installation Information  . . . . . . . . . . . . . . .3 Step 1: Ventilation Requirements  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Step 2: Cabinet Preparation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        For Massachusetts Installations: 1. Installation must be performed by a qualified or licensed contractor,  plumber or gas fitter qualified or licensed by the state, province or region  where this appliance is being installed. 2. Shut-off valve must be a “T” handle gas cock. 3. Flexible gas connector must not be longer than 36 inches. WARNING: If the information in this manual is not followed exactly, a fire or  explosion may result causing property damage, personal injury or  death. -- Do not st
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Safety Instructions Important Safety Instructions READ AND SAVE THESE INSTRUCTIONS AND GROUNDING MUST COMPLY WITH ALL  APPROVED FOR ALL RESIDENTIAL APPLIANCES APPLICABLE CODES. FOR RESIDENTIAL USE ONLY Electrical Power Supply 30'' Model: Before you Begin 4 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit  IMPORTANT: Save these Instructions for the Local  36" Models: Electrical Inspector’s use. 6 Burners - 120 VAC, 60 Hz., 1 Ph., 10 Amp circuit INSTALLER: Please leave these Instructions with this
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Important Installation Information  It is strongly recommended that this appliance be installed  CAUTION in conjunction with a suitable overhead vent hood. (See  To eliminate risk of burns or fire caused by  “Step 1: Ventilation Requirements”.)  reaching over heated surface units, cabinet  storage located above the surface units should  Check local building codes for the proper method of  be avoided.   appliance installation. Local codes vary. Installation,  electrical connections and grounding 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Consider Make-Up Air: NOTE: Ventilation hoods and blowers are designed for use with  • Due to the high volume of ventilation air, a source of  single-wall ducting. Some local building codes may require  outside replacement air is recommended. This is  double-wall ducting. Before starting installation, consult  particularly important for tightly sealed and insulated  local building codes and agencies to insure that the  homes.  installation will meet local requirements.  • A qualified heating and
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        7. When there is less than a 12" horizontal clearance  Step 2: Cabinet Preparation between combustible material  and the back edge of  1. To ensure professional results, the cabinet and  the cooktop above the cooking surface, a Thermador  countertop openings should be prepared by a qualified  Low Backguard must be installed. (See Step 6). When  cabinet worker.  clearance to combustible material  is over 12", a  2. The clearances shown in Figure 1 are required. The  Thermador Island Trim may be u
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                          30" to 36" Wide Hood for 30" Cooktop 36" to  42" Wide Hood for 36" Cooktop Combustible  Material    48" to  60" Wide Hood for 48" Cooktop VENT HOOD 30" Min. from bottom of  Overhead Hood to Cooking  Surface  (40" or greater if   hood contains combustible  materials     ). 13" Max.  40" Min. to  Horizontal  depth of  Combustible  Min. Clearance  overhead  Material       to Rear Wall: cabinets from Cooking  0" with Backguard Surface. 12" with Island Trim   18" Min 10" min.  Cooking Surface both 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        B D See Detail A B 23-5/16” Counter Sunk Screws  Figure 3: Wall Installation with Countertop Backsplash  Figure 2: Installing Side Supports (both sides) See Detail A 3/4” Min. D Vent Hood   Width Requirements Island – 42" or 48"  Wide Hood for 36" Cooktop 22-13/16” Island – 54" or 60" Wide Hood for 48" Cooktop  Figure 4: Island Installation (No Countertop Backsplash) English 7                                                                                                                         
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        30” Cooktop 36” Cooktop 48” Cooktop C A 29-7/8” 35-7/8” 47-7/8” B B 3/8” 3/8” 13/16” C 0” (Control Panel Projecting 1-1/4” from Base  Cabinet Face) 11/16” (Notch Required for Standard 24” - Deep  2 x 4 Corner 7-11/16” Base Cabinet, Control Panel Projecting 9/16” from  Support Base Cabinet Face) 1-1/4” (Control Panel Flush to  Cabinet Face - Min. 24-9/16” - Deep Base Cabinet  Required) D 29-1/8” 35-1/8” 46-1/4” Corner Notch Detail Detail A: (Front Face of Cabinet) 25-3/8” 12” 1/2” Side Flange 7-5
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Minimum 3/4" (19 mm) 11/16” Notch Depth 0" to  1-1/4" (0 - 32 mm) See Fig. 4  and T able  Dimension C (22, 9 cm) 9"   9/16” 1-7/8" (4,8 cm) Horizontal Distance  Between Cutouts Front projects outward 9/16" as shown from  2-3/4" (7 cm) Vertical Distance standard 24"-deep base. Between Cutouts (See Side View for Wood Support)  Figure 6: Projecting from Cabinet Front  Figure 8a: Installation of 48” Cooktop above two side-by- side Thermador Warming Drawers - Model No. WD24 7-11/16” (19,52 cm) 1-1/4”
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Product Rating Label/Serial Tag Threading compounds must be  resistant to Propane Gas  1/2" NPT 3/4” flex line 3” Min. Power Cord or gas flow Conduit 3-Prong grounding type receptacle  A manual valve must be installed  connected to a properly grounded and  external to the appliance, in an acces- polarized electrical supply rated at 120VAC,  sible location from the front, for the  10 Amps, (or 15A*)  Single Phase, 60 HZ. purpose of shutting off the gas supply.   Figure 9: Bottom of Unit All Insta
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        • The installer should inform the consumer of the  Step 4: Gas Requirements and Hookup location of the gas shut-off valve. Make sure all users  know where and how to shut off the gas supply to the  Cooktops are shipped by the factory to operate on  cooktop.  natural gas.They must be converted for use with  • The gas supply connections shall be made by a  propane. Verify the type of gas being used at the  competent technician and in accordance with local  installation site matches the type of gas
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Grounding Method  Step 5: Electrical Requirements,  Connection and Grounding The cooktop is factory equipped with a power supply cord  with a three-prong grounding plug (with polarized parallel  blades).  CAUTION Improper grounding or reverse polarization will  IT MUST BE PLUGGED INTO A MATING, GROUNDING  cause malfunction (such as continuous sparking  TYPE RECEPTACLE THAT IS CONNECTED TO A  of the burner igniters). This can damage the  CORRECTLY POLARIZED 120 VOLT CIRCUIT (See  appliance and ca
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Step 6: Backguard Installation A Low Back backguard must be installed when there is less  than a 12" clearance between combustible materials and  back edge of cooktop. (See Figure 1 and Figure 5.) For  island installations and other installations with over 12" C clearance, an optional stainless steel trim channel is    available to cover the backguard mounting flanges. Attach  the backguard before sliding the appliance into the final  B installed position. Follow Steps A through C below:  1. Sli
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Installer Checklist Yellow Flames: Final Check List  Further adjustment is required. • Cooktop correctly positioned in countertop recess.  Yellow Tips on Outer Cones: • Specified clearances maintained to cabinet surfaces.  Normal for LP Gas. • Burner caps positioned properly on burner bases.  Soft Blue Flames: • All packaging material removed. Normal for Natural Gas. • Island Trim or Backguard attached according to  instructions.  If the flame is completely or mostly yellow, verify that the  • T
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        To Clean and Protect Exterior Surfaces The stainless steel surfaces may be cleaned by wiping with Use a stainless steel cleaner/polish to protect the finish and  a damp soapy cloth. Any mild glass cleaner will remove maintain appearance.  fingerprints and smears.  DO NOT allow deposits to remain for long periods of time.  Follow all cleaning by rinsing with clear water. Wipe dry  with a clean soft cloth to avoid water marks. For DO NOT use ordinary steel wool or steel brushes. Small  discolorati
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Table des matières Instructions de sécurite  . . . . . . . . . . . . . . . . . . . . . . .2 Avant de comencer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Information importante à propos de l’installation  . .3 Chapitre 1 : Exigences de ventilation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Chapitre 2 : Préparation de l’emplacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Pour les installations au Massachusetts : 1. L’installation doit être réalisée par un entrepreneur qualifié ou agréé, un  plombier ou un installateur de gaz qualifié ou autorisé par l’État ou la région  dans laquelle cet appareil est installé.  2. Le robinet d’arrêt de gaz doit être pourvu d’une poignée en « T ».  3. La longueur maximum autorisée du tuyau de gaz est de 91,4 centimètres  (36").  AVERTISSEMENT L’information fournie dans le présent manuel doit être très  rigoureusement respectée, s
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Instructions de sécurite Instructions importants de sécurite LIRE TOUTES LES INSTRUCTIONS AVANT DE PROCÉDER du guide d’utilisation et d’entretien. Lorsque l'appareil est  APPROUVÉ POUR TOUT APPAREIL RÉSIDENTIEL installé, il est difficile d'accéder à l'information. POUR UTILISATION RÉSIDENTILLE SEULEMENT Veuillez lire toutes les instructions avant de poursuivre. IMPORTANT : LES RÉGLEMENTATIONS LOCALES  VARIENT. L’INSTALLATION, LES BRANCHEMENTS  ÉLECTRIQUES, LES RACCORDEMENTS AU GAZ ET LA  Avant d