 www.cmadishmachines.com 1203                                                                                                                                                                                                                                                                                                 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        TABLE OF CONTENTS  MODEL CMA-180UC  1. SPECIFICATIONS ........................................................................................ 2  1.1. CMA-180UC ......................................................................................................................... 2  1.2. CMA-180UC OPERATIONAL CYCLE...................................................................................... 3  2. GETTING STARTED..........................................................................
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                          1. Specifications  METRIC  EQUIVALENT  1.1. CMA-180UC  WATER CONSUMPTION    PER RACK .86 GAL. (3.25 L)  PER HOUR 20.6 GAL. (77.8 L)  OPERATING CYCLE    WASH TIME-SEC 94 94  RINSE TIME-SEC 16 16  DWELL TIME-SEC 10 10  TOTAL CYCLE 2 MIN. 2 MIN.  OPERATING CAPACITY    RACKS PER HOUR 30 30  WASH TANK CAPACITY 2.5 GAL. (9.46 L)  PUMP CAPACITY 38 GPM (144 LPM)  WATER REQUIREMENTS 140°F (60°C)  WATER INLET ½” —  DRAIN CONNECTION 1” —  2 RINSE PRESSURE SET 24 PSI 1.7 kg/cm CYCLE TEMPERATURES    WASH-°
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                          1.2. CMA-180UC Operational Cycle    The CMA-180UC Operational Cycle has a total cycle time of 2 minutes (120 seconds).  The  Timing Diagram and the steps listed below detail the individual functions that are executed  during each Operational Cycle.    Seconds:   0 10 20 30 40 50 60 70  80 90 100 110 120                           Instant                          Start Relay                                                    Cam Timer  Motor Cam                                                   
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Getting Started   2. Getting Started  2.1. Introduction to CMA-180UC  The CMA-180UC is a hot water sanitizing, single rack, under-counter dishmachine.  It is a  standalone machine featuring a self-contained booster heater.  The only external connections  necessary are power supply, water supply, drainpipe, and optional chemical dispensers.  The  machine uses re-circulated wash water and fresh water final-rinse.  Operation of the CMA-180UC is extremely user friendly.  To initially fill the machin
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Getting Started   2.2. Receiving and Installation  The dishwasher is shipped from the factory in a corrugated box on a wooden pallet.  The  installation guidelines give a systematic procedure for setting up the machine.  Start by removing the packaging material.  Unwrap the machine and check for the following  component parts:  The Wash Tank Scrap Screen is shipped inside the wash cavity of the machine. This screen must  be in place during operation.  It has been designed to perform two basic fu
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Getting Started   i. Run an appropriate length of ½” conduit from your dispenser to the mounting  plate where it will be secured.  The conduit needs to be of sufficient length  and flexibility to permit the machine to be moved for cleaning without having  to disconnect any wiring.  ii. Run your dispenser wires from the conduit through the enclosed area across  the top of the machine and feed them through the access hole provided in  the back of the control panel drawer.  2. With the machine’s po
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Getting Started   1 2.2.4. NOVA Detergent and Rinse Dispenser (Optional) .  The NOVA Detergent and Rinse Dispenser has its own reference manual.   Familiarize yourself with the dispenser’s reference manual before proceeding with  installation.  1. The NOVA dispenser is pre-wired with a multi-conductor electrical cable that is to  be run through a conduit to the power block inside the control panel drawer.  Use  a ½” watertight conduit meeting all local and national codes.  A conduit fitting is  
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Getting Started   Brown (LIVE) wire      Multi-conductor cable  Rinse Signal wires (Blue terminals)  Detergent Signal wires  (Red terminals)  Black (Main Power)  Gray/Violet  (Main Power Neutral)  (Same terminal as rinse neutral) Note: Machine Neutral (White wires)    Figure 2.2.4 Note: In Figure 2.2.4 the machine’s wire harness was left out of the back of the  power block to more clearly show the dispenser wires.  2. Remove the plug from the mixing chamber located by the vacuum breaker on the  
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Getting Started   2.2.5. Water Tempering Kit    MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 Page 9                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Getting Started   2.2.6. Booster Heater Setup  The booster tank must be filled with water before the heating element is energized.   For this reason the “High Limit Switch” has intentionally been activated at the factory  and will require resetting before the heating element will turn on.  Follow the procedure below to complete the initial installation:  1. Close the door on the machine.  2. Turn the Power switch to the "ON" position.  3. Hold the “FILL” switch in until water overflows into the 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Operation    3. Operation  3.1. Initial Setup  3.1.1. Rinse Pressure Regulator  The CMA-180UC requires a supply water input pressure of 24 PSI minimum.  This  pressure is then reduced by the supply water regulator.  Use the following  procedure to adjust the rinse pressure to 20 PSI:  1. Close the door on the machine.  2. Turn the Power switch to the "ON" position.  3. While holding the “FILL” switch—to activate the water solenoid—adjust the  pressure regulator until the gauge reads 20 PSI.  (Re
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Operation   3.3. Operating and Cleaning Instructions                                                                                MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 Page 12                                                                                                                                                                                                                                                                                                               
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Operation   3.4. Preventive Maintenance Chart    MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 Page 13                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Operation   3.5. Quick service guide  MODEL:  CMA 180UC HIGH TEMP UNDER COUNTER        TECHNICAL ISSUE CAUSE SOLUTION  Pressure regulator is not set properly Set regulator to 18-20 psi     Faulty rinse micro switch Replace micro switch, P/N 00411.00     Drain hose elevated too high  Must be lowered to goose neck level  Scrap trap over flows    Obstruction in drain hose Check hose & clean    Scrap exit screen Clean exit screen    Faulty drain pump  Replace pump, P/N 15503.00    Machine not level 
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Operation   3.6. Troubleshooting    PROBLEM LIKELY CAUSE SOLUTION  Machine inoperative Power off at circuit breaker Reset circuit breaker  Defective power switch Replace power switch  P/N: 15521.50 Motor inoperative Door is open Close door  Control panel is pulled out Secure control panel  Defective reed switch Replace reed switch  P/N: 00557.55 Defective timer assembly Replace timer assembly*  P/N: 14408.80 Defective pump motor contactor Replace contactor  P/N: 15504.00 Defective motor Replace 
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Operation   PROBLEM LIKELY CAUSE SOLUTION  Low heat during operation Low incoming water temperature  Turn up supply water heater  (below 140° F)  Insulate supply water pipe  Thermostat out of adjustment Adjust thermostat  Cold water mixing with supply Isolate hot water from cold  water  Defective heater Replace heater  P/N: 15517.00 Low rinse water pressure Pressure regulator out of Adjust pressure regulator  adjustment  Defective pressure gauge (actual Replace pressure gauge  pressure is okay) 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Operation   PROBLEM LIKELY CAUSE SOLUTION  Start switch requires > 1 Defective (Instant Start) ice cube Replace ice cube relay   second activation to run relay  P/N: 00631.00 cycle  Activating fill switch does Defective drain/fill switch Replace drain/fill switch  not fill machine  P/N: 15522.00 Defective water solenoid valve Replace water solenoid valve  P/N: 03603.10 Fill (rinse water) won’t shut Defective water solenoid valve Replace water solenoid valve  off  P/N: 03603.10 Defective drain/fi
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                           4. Parts Kit  4.1. Initial Parts Kit (P/N 1100.66)    P/N DESCRIPTION Qty  15504.00 Motor Contactor, 2-Pole 20 Amp 1  15504.50 Heater Contactor, 2-Pole 35 Amp 1  00501.00 2-Minute Timer Motor 1  00631.00 Ice Cube Relay 120 V 1  15521.00 Rocker Switch Start Momentary 1  15522.00 Rocker Switch Drain/Fill 1  15521.50 Rocker Switch Power Maintained 1  00557.55 Reed Switch 1  03623.00 1/2” Vacuum Breaker Repair Kit – Watts 1  00707.00 1/2” Water Solenoid Repair Kit – J/E 1  04103.00 L1X/L1-C Drain
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Parts Manual    4.2. Optional Drain Pump Kit          ITEM NO. ITEM NO.    P/N DESCRIPTION P/N DESCRIPTION  NO. REQ’D NO. REQ’D 1 1 15503.00 Drain Motor Ultra Jet for CMA-180UC 6 4 03101.00 Hose Clamp 1”  2 2 00432.50 Twist Tie 7 1 15603.00 Drain Line Gooseneck  3 1 15601.10 Black Drain Hose 1" ID X 3 1/2" 8 2 03801.10 10-32 SS Nut  4 1 15601.50 Drain Hose 1" ID, 6 ft 9 2 04806.00 #10 Brass Washer  5 1 15601.60 Robber Hose 90 Deg.      MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 Pa