ملخص المحتوى في الصفحة رقم 1 
                    
                        Lighting Systems IS_CD12 
               
 
 
 
  
  
  
    
 
9-3/16" (23.34cm)
NOTES:
1. Tools needed: hacksaw, screwdrivers, drill & pliers.
2. Self-driving type “tek” screws may be used in certain 
applications to assist in installation and preparation.
3. Be sure to keep fixture runs “As straight as possible” 
8-1/4"
for best results.
(20.96cm)
GENERAL DESCRIPTION:  
 
 
 
  
  
 
 
INSTALLATION: 
 
  
 
 
               
We reserve the right to change details of design, materials and fin
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Lighting Systems IS_CD12                  SELECTION / ORDERING GUIDE Example of Straight Run: 1.    at each end trim location for net linear footage. 2.   specify voltage 120 or 277. 21' 10-3/4" (667.39cm) O.A.L. 3/4" (1.91cm) 21' 9-1/4" (663.58cm) 3/4" (1.91cm) 45" 90" 90" (114.30cm) (228.60cm) (228.60cm) Telescoping  Example of Pattern Run: Unit 1.  2.  A.      3.   specify voltage 120 or 277.     6' 9" (205.74cm) O.A.L. 3/4" (1.91cm) 5' 8-1/4" (173.33cm) 12" (30.48cm) 12" (30.48cm) 33" (83.82
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Lighting Systems IS_CD12                  SELECTION / ORDERING GUIDE (CONT’D) CD12: One Lamp CD12 CD12-11T CD12-1190 CD12-1145 CD12-1133 CD12-1121              11  11  11  111  11 1  111  11  1 111  11 1  11 1  11 1  11 1 1  11 1 1  1 111  12  1 1111  12 1  12 1  12 1  12 1 1  12 1 1  1 211  13  1 2111  13 1  13 1  13 1  13 1 1  13 1 1  1 311  1   1 3111  1  1  1  1  1  1 1 inch = 2.45 centimeter                 We reserve the right to change details of design, materials and finish.             
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Lighting Systems IS_CD12                  SELECTION / ORDERING GUIDE (CONT’D) CD12: Two Lamps CD12 CD12-12T CD12-1296 CD12-1248 CD12-1236 CD12-1224              11  11  11  111  11 1  111  11  1 111  11 1  11 1  11 1  11 1 1  11 1 1  1 111  12  1 1111  12 1  12 1  12 1  12 1 1  12 1 1  1 211  13  1 2111  13 1  13 1  13 1  13 1 1  13 1 1  1 311  1   1 3111  1  1  1  1  1  1 1 inch = 2.45 centimeter                 We reserve the right to change details of design, materials and finish.            
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Lighting Systems IS_CD12                  PARTS LIST 1.  2.                             [ ] Service Entry Kits        NOTE: END OF RUN PLATES are shipped in the telescopic section cartons. END OF RUN PLATE HOUSING END OF RUN CAPS ELECTRICAL CHASIS END OF RUN PLATE LOUVER RETAINING CLIP SERVICE ENTRY KIT                 We reserve the right to change details of design, materials and finish.                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Lighting Systems IS_CD12                  INSTALLATION 1. TO INSTALL TROUGH HOUSING 2. TANDEM MOUNTING     other, attaching to each other and hanging on       NOTE: END OF RUN PLATES are shipped in the   telescopic section cartons.     HOUSING   SUSPENSION END OF RUN PLATE WIRE (by others) SCREW & NUT SCREW & NUT Figure 1 ALIGNER CLIPS Figure 2 3. TRIMMING TELESCOPIC FIXTURES 4. END OF FIXTURE RUN                SCREW & NUT SCREW & NUT      HOUSING TRIM ALIGNER CLIPS Figure 4 END PLATE Figure 3 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Lighting Systems IS_CD12                  INSTALLATION (CONT’D) 5. INSTALL ELECTRICAL CHASSIS                   HOUSING END OF RUN PLATE END OF RUN CAPS ELECTRICAL CHASIS END OF RUN PLATE Figure 5 RETAINING CLIP WIRING SCHEMATIC Showing continuous plug & socket connections. (Electrical chassis show separated for simplification) Service entry kit (power feed) CD6B Telescoping unit at end of in line (See page 5) This plug used for corner return connection Start electrical chassis installtion at th
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Lighting Systems IS_CD12                  INSTALLATION (CONT’D) TELE ELECTRICAL (ONE LAMP) TELE ELECTRICAL (TWO LAMP) A.  A.        section.           the channel of the chassis.   ELECTRICAL CHASSIS MOUNTING PLATE LAMP ARM WIRES CONDUIT Figure 7 Figure 8 SCREW 6. INSTALL LAMPS (Furnished by others) 7. INSTALL LOUVERS A.         INSIDE GROOVE Figure 9 LOUVER ASSEMBLY Figure 10                 We reserve the right to change details of design, materials and finish.                                 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Lighting Systems IS_CD12                  PATTERN RUN WITH CORNERS 1. FIXTURE RUNS USE 90° CORNERS TO CREATE PATTERNS    sheet.           HOUSING ALIGNER CLIP ELECTRICAL CHASSIS RETAINING CLIP CORNER HOUSING CORNER LOUVER FLEX CONDUIT SECTION Figure 11 CORNER LOUVER 2. TELE PREPARATION           Figure 12                 We reserve the right to change details of design, materials and finish.                                                                                                          
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Lighting Systems IS_CD12                  PATTERN RUN WITH CORNERS (CONT’D) 3. TELE INSTALLATION-INTO CORNER            HOUSING CORNER HOUSING Figure 13 4. CORNER-NEXT FIXTURE           SUSPENSION WIRE (by others) CORNER HOUSING Figure 14                 We reserve the right to change details of design, materials and finish.                                                                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Lighting Systems IS_CD12                  PATTERN RUN WITH CORNERS (CONT’D) ELECTRICAL CHASSIS INSTALLATION                  HOUSING ELECTRICAL CHASSIS RETAINING CLIP Figure 15 CORNER HOUSING FLEX CONDUIT 5. INSTALL LAMPS (FURNISHED BY OTHERS)  6. LOUVER INSTALLATION           HOUSING LOUVER Figure 16 CORNER LOUVER                 We reserve the right to change details of design, materials and finish.