                        H10X/H5X
H5E/DV PC
H5 ELEMENT
With Digital Control Board
SERVICE MANUAL
BUNN-O-MATIC CORPORATION 
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601    FAX: (217) 529-6644
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit
the Bunn-O-Matic website, at www.bunn.com.  This is absolutely FREE, and the quickest way to obtain
the latest catalog and manual updates.  Contact Bunn-O-Matic Corporation at 1-800-286-6070 to
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal servers  and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor.  2) All other equipment -  2 years parts and 1 year labor plus added warranties as specified below:  a) Electronic circuit and/or control boards - parts and labor for 3 years.   b) C
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        WARNING - Inspection, testing, and repair of electrical equipment should be performed only by qualified service  personnel. Disconnect the dispenser fromthe power source when servicing, except when electrical tests are  required and the test procedure specifically states to connect the dispenser to the power source. CONTENTS TroubleShooting ............................................................................................4 Component Access ..............................................
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems  encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic  Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service person- nel. • All electronic components have 120 – 240 volt ac and low voltage dc potential on their terminals. Shorting  of terminals or
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        TROUBLESHOOTING (cont.) Problem Probable Cause Remedy  Equipment will not operate 2. Safety overflow switch Refer to Service – safety overflow switch  (cont.) for testing procedures.  Automatic refill will not oper- 1. No water Check plumbing and shut-off valves. ate after drawing hot water. 2. Water strainer/flow control (A) Direction of flow arrow must be point- ing towards dispenser. (B) Remove the strainer/flow control and  check for obstructions. Clear or replace. 3. Liquid level system Ref
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        TROUBLESHOOTING (cont.) Problem Probable Cause Remedy  Water boils continuously. 1. Temperature control Refer to Service – electronic controls for  testing procedures. 2. Lime build-up Inspect the tank assembliy for excess lime  deposits. Delime as required. CAUTION – Tanks and tank components should be delimed reglarly depending on local water conditions. Exces- sive mineral build-up on stainless steel surfaces can initiate corrosive reactions resulting in serious leaks. Dispenser is making unu
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        SERVICE WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replacement  of any component. WARNING - Inspection, testing, and repair of electrical equipment should be performed only  by qualified service personnel. Disconnect the dispenser fromthe power source when servicing, except when  electrical tests are required and the test procedure specifically states to connect the dispenser to the power source.  Component Access - H5E/DV-PC/X   Component Acc
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                         t  t  t t This equipmen is o be ins alled o comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE Liquid Level Control Flow Charts Electronic Controls H5E, H5X LIQUID LEVEL CONTROL PROBLEM: Does Not Refill Yes Overflow Cup Full Remove Power ? Drain cup No Retry Disconnect Level Probe Yes Yes Voltage present at Does Water Flow Replace Probe Solenoid
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        SERVICE (cont.) Electronic Controls (cont.) 4. Remove the pink wire from terminal 5 of the elec- tronic control assembly. Liquid Level Control Test Procedure 5. Check the voltage across terminals 1 & 4 of the  1. Disconnect the dispenser from the power source. electronic control board with a voltmeter.  Connect  2. Check the voltage across terminals 3 & 4 of the  the dispenser to the power source. The indication  electronic control board with a voltmeter.  Connect must be: the dispenser to the p
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Electronic Controls (cont.) If voltage was not present as described, check the pink  7. Reconnect the pink wire to terminal 5 of the elec- probe wire and the green ground wire for continuity  tronic control assembly. 8. Loosen the compression fitting, remove the probe and/or replace the probe. from the tank lid, and inspect it for mineral depos- Temperature Control Test Procedure its.  Replace it if necessary. Keep the exposed ends  of the probe away from any metal surface of the  1. Disconnect 
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        SERVICE (cont.) Electronic Controls (cont.) If voltage was present as described, the temperature  control of the system is operating properly. If voltage was not present as described, contact  Bunn-O-Matic to order an electronic control board and  temperature sensor for evaluation and proceed to #9. 6. Replace the electronic control board. T5 PNK to Liquid  7. Check the voltage across the tank heater terminals  Level Probe with a voltmeter. Connect the dispenser to the T4 WHI or RED to  Terminal
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) If voltage was present as described, reconnect the black  Limit Thermostat wire and proceed to #5. Location: If voltage was not present as described, refer to the Wir- The limit thermostat is located on the tank lid. ing Diagrams and check the dispense
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Removal and Replacement: Safety Overflow Switch 1. Disconnect the black wires from the safety overflow  switch. 2. Remove the nut beneath the copper overflow cup. 3. Remove the entire switch assembly from the cup. 4. Place the new switch assembly into 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        ill i i li l l i i l l l i ll i ll i l l l l i l i l ! WARNING F water tank before turn ng -on thermostat or connect ng app ance to power source. Use on y on a proper y protected c rcu t capab e of the rated oad. E ectr ca y ground the chass s. Fo ow nat ona / oca e ectr ca codes. Do not use near combust b es. FAILURE TO COMPLY RISKS EQUIPMENT AMAGE, FI E, OR SHO K AZAR D R C H D READ THE ENTIRE OPERATING MANUAL INCLUDING THE LIMIT OF WARRANTY AND LIABILITY BEFORE BUYING OR USING THIS PRODUCT TH
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        SERVICE (cont.) Solenoid Valve (Early Models) If continuity is present as described, reconnect the  wires and proceed to #7. Location: If continuity is not present as described, replace the  The solenoid valve is located behind the large access  solenoid valve coil. panel on the left side of the dispenser. To test the solenoid valve, access will also be needed  7. Check the solenoid valve for coil action. Connect  to the electronic control board. the dispenser to the power source. Listen careful
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Tank Heater 4. Remove the tank heater from the tank lid and in- Location: spect it for cracks in the sheath. The tank heater is located in the tank lid. If the sheath shows no sign of damage, proceed to #5. If the sheath is damaged, replace the tank he
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        SERVICE (cont.) Removal and Replacement: Steam Sensor (Thermistor) 1. Disconnect the dispenser from the power source. 2. Disconnect the thermistor from J5 on control  Location: board. The thermistor is located on the end of the overflow  3. Loosen the set screw and the two screws securing  tube above the overflow cup. the two half blocks together. Remove thermistor  To test the thermistor, access will also be needed to  assembly from overflow tube. the electronic control board. 4. Install new th
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        SERVICE (cont.) Dispense Valve (PC Only)  If voltage is not present as described, refer to Wir- Location: ing Diagrams and check the dispenser wiring harness.  The Dispense Valve is located behind control panel. Also check the control board for proper operation. Removal and Replacement: 1. Disconnect the dispenser from the power source  and allow to cool. 2. Drain enough water from the tank so the water level  is below the outlet. Bracket 3. Remove the nut and flare nut from the valve. Shroud 4.
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        MEMBRANE SWITCH ASSY Ready Power Heater Manual Dispense/Stop Left Dispense Middle Dispense Right Dispense “Hidden” Switch    J2     6        10         1        5      N L2 L1 SCHEMATIC WIRING DIAGRAM H5E-DV PC GRN BLK-14 RED-14 Earth Ground MASTER ON/OFF SWITCH Chassis Ground RED-14 BLK-18 SELECTOR LIMIT SWITCH TANK HEATER THERMOSTAT BRN-14 BLK-14 BLK-14 4000 W TANK HEATER WHI/VIO-14 WHT-14 1800 W N.C. REFILL WHT-18 WHI/BLU-18 120VAC SOL OVERFLOW PROTECTION SWITCH 4 3 WHI-18    J7 2 1 WHT-18 VI
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        MEMBRANE SWITCH ASSY Ready Power Heater Manual Dispense/Stop Left Dispense Middle Dispense Right Dispense “Hidden” Switch    J2     6        10         1        5      L1 L2 SCHEMATIC WIRING DIAGRAM H5E-PC GRN RED-14 BLK-14 Earth Ground EMI FILTER Chassis Ground BLK-18 RED-14 LIMIT LIMIT THERMOSTAT THERMOSTAT TANK HEATER BLK-14 BLK-14 BLU-14 BLU-14 4000 W N.C. REFILL WHI/BLU-18 230VAC RED-18 OVERFLOW SOL PROTECTION SWITCH 4 3 RED-18 DISPENSE    J7 2 1 RED-18 VIO-18 230VAC SOL 5 4 N.O. 3 COM 2 1