ملخص المحتوى في الصفحة رقم 1 
                    
                        INSTALLATION & OPERATION MANUAL FOR 
Charbroilers 
 
 
 
 
 
 
MODELS MLS 
VCCB25 ML-114540 
VCCB30 ML-114541 
VCCB36 ML-114542 
VCCB47 
ML-114543 
VCCB60 ML-114544 
VCCB72 ML-114545 
www.vulcanhart.com 
 
 
 
MODELS MLS 
 
  
SCB25 ML-767100 
SCB30 ML-767101 
SCB36 ML-767102 
SCB47 ML-767103 
SCB60 
ML-767104 
SCB72 ML-767105 
www.wolfrange.com 
 
 
  
 
 
 
 
 
  
ITW Food Equipment Group, LLC 
FORM F-36952 (06-06)
An Illinois Tool Works Company 
701 South Ridge Avenue, Troy, OH 45374 
       
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        IMPORTANT FOR YOUR SAFETY    THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO  INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD  START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS  MANUAL.    POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN  THE EVENT THE SMELL OF GAS IS DETECTED.  THIS INFORMATION CAN BE  OBTAINED FROM THE LOCAL GAS SUPPLIER.        IMPORTANT  IN THE EVENT A GAS ODOR IS DETECTED, SHUT  DOWN UNITS AT MAIN SHUTOFF VALVE AND  CONTACT THE LO
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        INSTALLATION, OPERATION AND CARE OF  GAS COUNTERTOP CHARBROILERS    GENERAL    Gas Countertop Charbroilers are designed for commercial use only and feature fast,  efficient gas heat.  Each burner is controlled by an adjustable gas valve. Cast radiants  are located directly above each burner to maintain uniform temperature. Radiants are  easily removed for cleaning when cool.    Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid  surface to be level or sloped
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        LOCATION  The installation location must be kept free and clear of combustibles.  Do not obstruct the  flow of combustion and ventilation air. DO NOT install the charbroiler adjacent to open  burners or fryers.  Sufficient air should be allowed to enter the room to compensate for the amount of air  removed by any ventilating system and for combustion of the gas burners.  Do not  obstruct the air flow into and around the appliance.  Do not obstruct the flow of flue gases  through and above the br
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        LEVELING  If the charbroiler is equipped with legs or is mounted on the optional stand equipped with  legs, turn the feet at the bottom of the legs in or out to level the broiler in the final  installed location.  If the broiler is mounted on the optional stand equipped with casters,  position the charbroiler on a level floor.  VENTILATION HOOD  The broiler should be installed under a suitable ventilation hood. For safe operation and  proper ventilation, keep the space between the charbroiler an
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        GAS PRESSURE REGULATOR INSTALLATION  Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C.  for propane gas. No further adjustment should be required.  Install the regulator as close to the broiler on the gas supply line as possible. Make sure  that the arrow on the underside of the regulator is oriented in the direction of gas flow to  the broiler (Fig. 2) and the regulator is positioned with the vent plug and adjustment  screw upright (Fig. 3).     Fig. 2 Fig
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        OPERATION  WARNING:  THE CHARBROILER AND ITS PARTS ARE HOT.  USE CARE WHEN  OPERATING, CLEANING, OR SERVICING THE CHARBROILER.     OFF ON  CONTROLS (Fig. 2)  BURNER VALVES    Fig. 2  All orifices are of the fixed type and require no adjustment.  Standing pilots should be adjusted to provide a slight yellow tip on the flame.  Pilots may  be lighted by removing adjacent cast iron top grates and radiants.    Air shutters on the main burners must be individually adjusted to provide a blue flame.   A
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        CLEANING    Scrape top grates thoroughly so grease flows to trough and grease drawer uninhibited.   This prevents flare ups.    Top grates may be immersed in commercial cleaning compound overnight.  In the  morning, rinse with hot water to remove any residues of cleaning compound.      With top grates removed, the trough at the front of the broiler can be removed for  cleaning (use wire brush).    Stainless steel surfaces may be cleaned using damp cloth with mild detergent and water  solution.