ملخص المحتوى في الصفحة رقم 1 
                    
                         
RuggedSwitch ™ 
i800 Family 
 
 
Installation Guide 
www.ruggedcom.com                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Copyright  COPYRIGHT © 2008 RuggedCom Inc.  ALL RIGHTS RESERVED  Dissemination or reproduction of this document, or evaluation and communication of its contents, is not  authorized except where expressly permitted. Violations are liable for damages. All rights reserved,  particularly for the purposes of patent application or trademark registration.  This document contains proprietary information, which is protected by copyright. All rights are reserved.  No part of this document may be photocopi
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Federal Communications Commission Radio  Frequency Interference Statement    This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC  Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is  operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not  installed and used in accordance with the instruction ma
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Table of Contents  Table of Contents  Federal Communications Commission Radio Frequency Interference Statement ..3  Table of Contents............................................................................................................4  Table of Figures ..............................................................................................................4  1 Product Overview....................................................................................................5  1.1 F
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Product Overview  1 Product Overview  1.1 Functional Overview  The RuggedSwitch™ i800, or i-Series, is a family of compact, fully managed  Ethernet switches designed to operate reliably in harsh industrial environments. The  flexibility of the i800 family allows the user to choose from managed or unmanaged,  regular or extended temperature, and a mix of fiber optic or copper interfaces, and  fast or Gigabit Ethernet. With up to nine Ethernet ports, the i800 is the perfect choice  for a wide vari
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Product Overview  1.3 i800 Family Front Panel View  Power Connector  Fail-Safe  Relay  Power LEDs  i802 Power 1 Power 2 Alarm Alarm LED  Ports 5-7, 7&8, or 9:  10/100/1000Base Tx,  8 100FX, 1000SX/LX  Fiber port LEDs  7 Speed LEDs (top)  56 Link/Act LEDs  (bottom)  Ports 1 – 4/6/8:  3 4 10/100 BaseTx  1 2 R RS-232  Console Port  Memory Slot    Figure 1: Front Panel    The front panel shown is representative of the i800 family. Note that there are  several Ethernet options available in several mo
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Product Overview  1.3.1 Front Panel LEDs  ITEM Color Activity Comments  Power status Green Solid Power On  Alarm status Red Solid Alarm condition exists  Blinking Link Established  Fiber port status Yellow  Solid Tx/Rx Activity  RJ45 Speed Yellow Solid 100Mbps  Solid Link Established  RJ45 Link/Act Yellow  Blinking Tx/Rx Activity  Table 1: Status LEDs  Note that the LEDs on all RJ45 Ethernet ports regardless of port orientation are  connected such that the top LED of each port is always the Spee
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Product Overview  1.4 i800 Family Top Panel View  back  DIN Rail  mounting  bracket  P1+ P1- Power  Fail-Safe  GND Connector  Relay  P2- P2+ Chassis  Ratings: Ground  12-24V , , 2A front   Figure 2: Top Panel    For details on connecting the power supplies and Ground, see Section 2.2.  For details on connecting the Fail-Safe Relay, see Section 2.3  RuggedCom® 8 RuggedSwitch™i800 family                                                                                                                
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Product Overview  1.5 i800 Family Bottom Panel View  Ports 5-7, 7&8, or 9:  Ports 1 – 4/6/8:  10/100/1000Base Tx,  10/100Base Tx 100FX, 1000SX/LX  front Micro-SD  MEMORY SLOT Memory Slot  RS-232  Console Port  CONSOLE 57600-N-8-1 DIN Rail  mounting  back  bracket    Figure 3: Bottom Panel    For details on connecting the console port, see Section 2.4.  For a description of the memory slot, see Section 2.6.  RuggedSwitch™i800 family 9 RuggedCom®                                                    
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Installation  2 Installation  2.1 DIN Rail Mounting  The i800 family of switches comes with a standard DIN rail mounting bracket. Figure  4 details the mounting configuration for a standard 1” DIN Rail.  DIN Rail  i802 Power 1 Power 2 Alarm 8 7 56 3 4 1 2 R DIN Rail mounting bracket  Release direction    Figure 4: DIN Rail Mounting    RuggedCom® 10 RuggedSwitch™i800 family                                                                                                                             
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Installation  2.2 Power Supply Wiring and Grounding  front  back  DC Input 1 DC Input 2 Chassis  Ground    Figure 5: DC Power supply and ground connections    The low voltage DC power supply features reverse polarity protection and dual  independent inputs, allowing the connection of two DC sources with the same  nominal voltage to provide redundant power supplies. A list of power and ground  connections follows in Table 3.    Pin Function Connector  P1+ DC Power Supply 1 positive terminal Phoen
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Installation  Figure 6 illustrates the connections required for both single and dual power supply  configurations:    Figure 6: Power Supply Wiring Examples    NOTES:  • Connect to the DC inputs according to the polarity markings on the unit.  • Chassis Ground must be connected to the protective earth.  • The internal connection between P1-. P2-, and GND means that if two power  supplies are connected to the unit, their negative terminals must be at the same  potential.  • Equipment must be inst
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        P1+ P1- GND P2- P2+ Ratings: 12-24V , , 2A Installation  2.3 Failsafe Output Wiring  The Failsafe output relay is provided via a Phoenix connector to signal critical error  conditions that may occur on the unit. The contacts are energized upon power up of  the unit and remain energized until a critical alarm condition or power loss occurs. A  common application for this output is to signal an alarm in the event of power failure.  front back Normally Open  Normally Closed  Common   Figure 7: Fail
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Installation  2.4 RS232 Console Port Wiring  The RS232 Console Port is used for initially configuring the unit. The connection is  made using a DB9-Female to RJ45 console cable with the pin-outs listed in Table 5.  Pin 8 Pin 1    Figure 8: RS232 Female DCE pin-out    RuggedCom RS232 over RJ45 pin-out specification  Signal Name (PC is DTE) DB9- Female RJ45 Male  DCD – Carrier detect 1 2  RxD – Receive data (to DTE) 2 5  TxD – Transmit data (from DTE) 3 6  DTR – Data terminal ready 4 3  Signal GND
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Installation  2.5 RJ45 Ports – Signal Description  10/100Base-TX ports allow connection to standard Category 5 (CAT-5) unshielded  twisted-pair (UTP) cable with RJ45 male connectors. The RJ45 receptacles are  directly connected to the chassis ground on the unit and can accept CAT-5 shielded  twisted-pair (STP) cables. If shielded cables are used, care must be taken to ensure  that a ground loop is not formed via the shield wire and the RJ45 receptacles at  either end. Figure 9 shows the RJ45 por
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Installation  2.6 Memory Slot  The i800 family of switches feature a removable microSD memory module to support  the following features:  • Configuration update and backup  • Redundant firmware image  • Greatly expanded logging capability  • Fault-tolerant firmware update    In case of unit failure, remove power from the unit and unplug any attached network,  alarm, and console cabling. Carefully remove the memory card, observing the  following precautions:  • Power down the unit before removing
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Technical Specifications  3 Technical Specifications  3.1 Type Test Specifications  IEC 61000-6-2 EMC: Generic Standards - Immunity for industrial environments  Test Description Levels  Enclosure Contact +/- 4kV  IEC 61000-4-2 ESD  Enclosure Air +/- 8kV  IEC 61000-4-3 Radiated RFI Enclosure ports 10 V/m, 80 to 1000Mhz  Signal ports +/- 1kV @ 5kHz  Burst (Fast  IEC 61000-4-4  Transient)  DC Power ports +/- 1kV @ 5kHz  Signal ports +/- 1kV line-to-earth/line  IEC 61000-4-5 Surge  +/- 0.5kV line-to
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Technical Specifications  3.2 Environmental Specifications  Parameter Range Comments  Ambient Temperature as measured from  Ambient Operating -20 to 60 °C  a 30 cm radius surrounding the center of  Temperature  -40 to 85 °C (Optional)  the enclosure.  Ambient Storage    -40 to 85 °C  Temperature  Ambient Relative  up to 95% Non-condensing, 55 °C, 6 cycles  Humidity  Vibration 1g (10-500Hz)  Shock 30g 11ms  Table 9: Environmental Specifications    3.3 Power Supply Specifications  Maximum  Power S
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Technical Specifications  3.5 RJ45 Ethernet Port Specifications  Data Port Media Distance Connector Type  10/100 Mbps CAT-5 UTP or STP 100m RJ45  Table 13: RJ45 Ethernet Port Specifications    3.6 Fiber Optic Port Specifications  Order Speed Mode / Cable Type  Tx (nm)  Code Standard Connector (um)  _FG01 1000SX MM/LC 850 62.5/125  _FG03 1000LX SM/LC 1310 9/125  _FX11 100FX MM/LC 1310 62.5/125  _FX06 100FX SM/LC 1300 9/125  Table 14: Fiber Optic Port Specifications    Rx Rx Power  Order Tx min Tx
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Technical Specifications  3.7 Physical Dimensions  i802 Power 1 Power 2 Alarm 8 7 5.296 4.625 56 4.421 3.833 3 4 1 2 R 0.833 0.246 0.460 2.225 3.050 3.750 3.918 MEMORY SLOT 3.490 3.918 CONSOLE 57600-N-8-1 NOTE: All dimensions are in inches.   Figure 10: Mechanical Specifications    Parameter Value Comments  4.625 x 2.25 x 3.75 inches  Dimensions (height x width x depth)  (117 x 57 x 95 mm)  Weight 1.5 lb (0.68 Kg)   Enclosure Die cast Aluminum   Table 16: Physical Dimensions  RuggedCom® 20 Rugge