ملخص المحتوى في الصفحة رقم 1
INSTALLATION INSTRUCTIONS
HOOD MODELS – WPN
By CNP INDUSTRIES, INC.
P.O. Box 18645 Anaheim, Ca 92817 (877) 387-6721
PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector's use.
INSTALLER: Please leave these Installation Instructions with this unit for owner.
OWNER: Please retain these Instructions for future reference
IMPROTANT SAFETY INSTRUCTIO
ملخص المحتوى في الصفحة رقم 2
BACKDRAFT DAMPER: It is recommended that a backdraft damper be used SAFTY WARNING: Turn off power circuit at in all installations. In cold weather installations it is necessary to use a backdraft . damper to minimize backflow of cold air into room. A non-metallic thermal the service entrance and break should also be used to minimize conduction of outside temperatures lockout panel before through the ductwork. The thermal break should be located as close as possible wiring the rang
ملخص المحتوى في الصفحة رقم 3
FIG-2 FIG - 1 BOTTOM VIEW OF CABINET - FOR MODEL WPN WIRING ACCESS B 1 2 B A 2 5" ROTATE ROTATE INTO INTO C 1 10 12" POSITION POSITION 4 1 1 7 7 1 8 8 4 2 VERTICAL DISCHARGE HORIZONTAL DISCHARGE 3 4 BACK WALL ADD FURRING STRIPS TO PROVIDE AN EVEN BOTTOM SURFACE FOR THE HOOD MOUNTING FIG - 3 FIG - 4 HORIZONTAL DISCHARGE C HOOD L 8" A TO DISCHARGE W/ROOF OF WALL CAP 5" 1 10 2 10" VERTICAL DISCHARGE 1 TRANSITION #10100 4 12" 2 1 7 8 2" 15" 1 14 4 CUT HOLE IN DRYWALL TO ACCEPT TRANSITION 15" # 10
ملخص المحتوى في الصفحة رقم 4
DUCT COVER INSTALLATION INSTRUCTION FOR WPN MODELS PLEASE READ DUCT COVER AND HOOD INSTRUCTION COMPLETELY BEFORE PROCEEDING WITH INSTALLATION PARTS: One 15” Duct Cover Section One 19” Duct Cover Section One Duct Cover Bracket Two #8 x 1-1/2” Screws (Mount duct cover bracket to ceiling) Four #8 x 3-1/2” Screws Secure duct cover section 1 and 2) Four #8 x 1/2“ Screw Mount duct cover to hood) Your WPN model hood includes a duct cover, which can be used as an alternate installation me
ملخص المحتوى في الصفحة رقم 5
1) Decide on hood location, position above cooking surface and type of air discharge to be used (See Hood Installation Instruction). When using the Duct Cover(s) plan on spacing from the top of the hood to the ceiling 1/8” larger than the duct cover length being used. This allows assembly of the duct cover after installation of the hood, electric connections and ducting. The small gap, at top of duct, remaining after installation will not be noticeable in most applications. If necessary a
ملخص المحتوى في الصفحة رقم 6
3) Mount the hood and install wiring and ducting per Hood Installation Instruction. 4) When using Duct Cover sections 1 & 2, set in length of duct needed and secure sections together using four #8 x 3/8” screws. Flanges on Duct Cover Section should be positioned facing toward same end of Duct Cover assembly. HINT: Predrive screws into holes, remove screws, remove protective cover from Duct Cover Sections, assemble Duct Cover sections and set length (Use extreme caution to avoid scratchin
ملخص المحتوى في الصفحة رقم 7
RECEPTACLE POWER SUPPLY PLUG N G L1 RECEPTACLE BLOWER BOX MOTOR 18 B # 12 18 G # 11 18 W # 25 18 W 1 1 18 B 18 B # 24 2 2 18 BL #23 18 BL 3 3 18 R # 22 18 R 18 W # 13 4 4 18 BL # 3 18 W # 10 18 B # 2 18 R # 4 18 B # 7 18 W # 9 LEFT RIGHT LIGHT LIGHT 1 A 3-SPD 1 2 3 LIGHT ROTARY 18 B # 6 2 SWITCH SWITCH 3 4 5 6 B 18 B # 8 18 W # 5 WIRING DIAGRAM-INTERNAL BLOWER & LIGHTING RECEPTACLE POWER SUPPLY PLUG N G L1 RECEPTACLE BLOWER BOX MOTOR 18 B # 12 18 G # 11 18 W # 25 18 W 1 1 18 B # 24 18 B 2 2 18