ملخص المحتوى في الصفحة رقم 1 
                    
                        UNVENTED (VENT-FREE) GAS STOVE HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Golden Oak Logs Shown
 MODELS CSBNT, CSBPT, CSPBNT, CSPBPT, CSPINT, CSPIPT
Propane/LP and Natural Gas Thermostat Control Gas Log Heaters
(Burner System For Cast Iron Stoves)
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation  and operational procedures. For assistance or addi- tional information consult a qualified installer, service  agency or the gas supplier. WARNING: This is an unvented gas-fired heater. It uses  air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must  be provided. Refer to Ai
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        SAFETY INFORMATION  WARNING: Do not use a   WARNING: This product con- blower insert, heat exchanger  tains and/or generates chemicals insert or other accessory not ap- known to the state of California proved for use with this heater.  to cause cancer or birth defects  or other reproductive harm. Due to high temperatures, the  appliance should be located out  IMPORTANT: Read this owner’s  of traffic and away from furniture  manual carefully and completely and draperies. before trying to assemble,
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        17. Operating heater above elevations of 4,500  SAFETY INFORMATION feet could cause pilot outage.  Continued 18. For propane/LP units, do not use propane/LP  4. This heater shall not be installed in a bedroom  tank of less than 100 lb. capacity. or bathroom. 19. Provide adequate clearances around air  5. Do not place stove directly on carpeting,  openings.  vinyl tile or any combustible material other  20. Screen must be completely closed before using  than wood. The stove must set on a metal  h
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        All spaces in homes fall into one of the three fol- PRODUCT FEATURES lowing ventilation classifications: OPERATION 1. Unusually Tight Construction This heater is clean burning. It requires no outside  2. Unconfined Space venting. There is no heat loss out a vent or up a  3. Confined Space chimney. Heat is generated by realistic, dancing  The information on pages 5 through 7 will help  yellow flames. This heater is designed for vent-free  you classify your space and provide adequate  operation. State
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                         Example: 51,200 Btu/Hr (maximum the   AIR FOR COMBUSTION   space can support)  AND VENTILATION   70,000 Btu/Hr (actual amount of   Continued   Btu/Hr used) DETERMINING FRESH-AIR FLOW The space in the above example is a confined  space because the actual Btu/Hr used is more than  FOR HEATER LOCATION the maximum Btu/Hr the space can support. You  Determining if You Have a Confined or  must provide additional fresh air. Your options  Unconfined Space are as follows: Use this work sheet to determine i
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        AIR FOR COMBUSTION UNPACKING 1. Lift off corrugated box enclosing stove  AND VENTILATION body crating. Continued  2. Remove screws fastening back and top of wood  frame enclosure. Two or more people must care- fully lift stove up and out of wooden crate.  12" 3. Remove plastic bag from stove body. 4. Remove back panel from stove (see Figure 4).  Ventilation Ventilation Grills  Grills  Use an adjustable wrench or a 10 mm socket.  Into Adjoining Room, Into Adjoining  Or Option 2 Remove four (4) bo
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        IMPORTANT: Vent-free heaters add moisture to  INSTALLATION the air. Although this is beneficial, installing heater  in rooms without enough ventilation air may cause  NOTICE: This heater is intended  mildew to form from too much moisture. See Air  for use as supplemental heat.  for Combustion and Ventilation, page 5. Use this heater along with your  CHECK GAS TYPE primary heating system. Do not  Use the correct gas type (natural or propane/LP) for  install this heater as your pri- your unit. If y
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        CONNECTING TO GAS SUPPLY INSTALLATION Continued  WARNING: This appliance  Ceiling requires a 1/2" NPT (National  Pipe Thread) inlet connection to  48" Minimum the pressure regulator. 12" 12" Side Wall Minimum Minimum Side Wall  WARNING: A qualified service  person must connect heater to gas  supply. Follow all local codes.  CAUTION: Never connect  Front View propane/LP heater directly to the  propane/LP supply. This heater  Back Wall requires an external regulator  6 " Minimum (not supplied). Ins
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        INSTALLATION  WARNING: Use pipe joint  Continued sealant that is resistant to liquid  For propane/LP units, the installer must supply  petroleum (LP) gas.  an external regulator. The external regulator will  reduce incoming gas pressure. You must reduce  We recommend that you install a sediment trap in  incoming gas pressure to between 11 and 14 inches  supply line as shown in Figure 8. Locate sediment  of water. If you do not reduce incoming gas pres- trap where it is within reach for cleaning.
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Test Pressures Equal To or Less Than  INSTALLATION 1/2 PSIG (3.5 kPa) Continued 1. Close equipment shutoff valve (see Figure 9). CHECKING GAS CONNECTIONS 2. Pressurize supply piping system by either  opening propane/LP supply tank valve for   WARNING: Test all gas piping  propane/LP gas or opening main gas valve  and connections, internal and located on or near gas meter for natural gas  or using compressed air. external to unit, for leaks after  3. Check all joints from gas meter for natural or
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        INSTALLING LOG SET INSTALLATION 1. Set one-piece log on heater base as shown in  Continued Figure 14. Make sure middle section at bot- Equipment  tom of log is seated into "U" shaped cutout in  Shutoff Valve center of heater base. Log will fit securely on  base. IMPORTANT: Make sure log does not  cover any burner ports and does not touch the  Gas Meter stove cavity (see Figure 14). 2. Fasten back panel to stove with four (4) bolts  and washers removed in step 4 of Unpacking,  page 7. Make sure pr
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        4. Wait five (5) minutes to clear out any gas.  OPERATING HEATER Then smell for gas, including near the floor.  FOR YOUR SAFETY   If you smell gas, STOP! Follow “B” in the  READ BEFORE LIGHTING safety information, column 1. If you donʼt  smell gas, go to the next step.  WARNING: If you do not fol- 5. Turn control knob counterclockwise   to the PILOT position. Press in control knob  low these instructions exactly,  for five (5) seconds (see Figure 16).  a fire or explosion may result   Note: You may 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Note: The correct pilot flame on natural gas units  OPERATING HEATER will have a slight curve, but flame should be blue  Continued and have no yellow or orange color. TO TURN OFF GAS  Thermocouple TO APPLIANCE Pilot  Shutting Off Heater Burner Turn control knob clockwise  to the  OFF position. Figure 18 - Correct Pilot Flame Pattern  Shutting Off Burners Only (pilot stays lit) (Propane/LP Shown) Turn control knob clockwise  to the  PILOT position. Pilot Burner Thermocouple THERMOSTAT CONTROL  OPER
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Injector Holder CLEANING AND  (May Be Brass or  MAINTENANCE Aluminum Depending  Burner  Continued on Model) Tube BURNER INJECTOR HOLDER AND  PILOT AIR INLET HOLE Primary Air Inlet  Holes (Shape of  The primary air inlet holes allow the proper amount  Holes May Vary  of air to mix with the gas. This provides a clean  by Model) burning flame. Keep these holes clear of dust, dirt,  lint and pet hair. Clean these air inlet holes prior to  Figure 20 - Injector Holder On Outlet  each heating season. Bl
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        TROUBLESHOOTING  WARNING: Turn off heater and let cool before servicing. Only a  qualified service person should service and repair heater.  CAUTION: Never use a wire, needle or similar object to clean  ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed,  1. Ignitor electrode not con- 1. Reconnect ignitor cable there is no spark at ODS/pilot nected to ignitor cable 2. Ig
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        TROUBLESHOOTING Continued  OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/ 1. Burner orifice clogged 1. Clean burner (see Cleaning  pilot is lit and Maintenance, page 14) or  replace burner orifice 2. Inlet gas pressure is too low 2. Contact local natural or pro- pane/LP gas company Delayed ignition burner 1. Manifold pressure is too low 1. Contact local natural or pro- pane/LP gas company 2. Burner orifice clogged 2. Clean burner (see Cleaning  and Maintenance, page 14) or 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        TROUBLESHOOTING Continued  WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your  building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,  paint remover, cigarette smoke, ceme
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        PARTS UNDER WARRANTY SPECIFICATIONS Contact authorized dealers of this product. If  CSBPT, CSPBPT, CSPIPT  they canʼt supply original replacement part(s),  (Includes 111485-01 Burner Chassis) call DESA Heating Productsʼ Technical Service  Btu (Variable) 16,000/30,000 Department at 1-866-672-6040. Type Gas  Propane/LP Only When calling DESA Heating Products, have ready Ignition Piezo • your name Pressure Manifold  8" W.C. • your address Inlet Gas Pressure (in. of water)          • model and seria
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        ILLUSTRATED PARTS BREAKDOWN MODELS 111485-01 AND 111485-02 1 17 2 15 9 7 8 10 6 12 5 15 4 18 18 11 13 3 14 16 18 20 www.desatech.com 111487-01D