ملخص المحتوى في الصفحة رقم 1 
                    
                        Automatic Wrist  
Blood Pressure Monitor  
BPW-201
El manual 
Ver. A
en español 
empieza en la 
página 44                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Risk Category Index ...................................... 27 TABLE OF CONTENTS Irregular Heartbeat Detector (IHB) .............. 28 INTRODUCTORY INFORMATION: Recalling Values from Memory ..................... 30 Important Product Notices and   Clearing Values from Memory ...................... 32 Safety Instructions .......................................... 5 Important Notes Regarding Your   About Blood Pressure ..................................... 7 Blood Pressure Measurement ...............
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        women and for users with irregular heartbeat,  IMPORTANT PRODUCT NOTICES AND  diabetes, poor circulation of blood, kidney problems  SAFETY INSTRUCTIONS or for users who have suffered from a stroke. When using your blood pressure monitor, basic  •  Consult your physician before measuring blood  precautions should always be followed. Please  pressure at the wrist if you have any of the following  read and follow all instructions and warnings before  conditions: Severe hypertension, severe diabetes
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Blood pressure measurements determined with  Why Measure Your Blood Pressure? this device are equivalent to those obtained by  Among today’s various health problems, those  a trained observer using the cuff/stethoscope  associated with high blood pressure are very common.  auscultatory method, within the limits prescribed by  High blood pressure dangerously correlates with  the American National Standard, Manual, electronic,  cardiovascular diseases. Therefore, blood pressure  or automated sphyg
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Although one can easily find where their own blood  BLOOD PRESSURE STANDARD pressure readings fall on this table, this monitor comes  The table below contains defined levels for hypertension  equipped with a Risk Category Index that automatically  that are publicly available from the National Heart Lung  compares each reading to the defined levels and  and Blood Institute at the U.S. National Institutes of Health  provides a helpful cue if your reading falls into one of the  (NIH)   stages that 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        NAME/FUNCTION OF EACH PART  individual. With one touch of a button, the cuff will  automatically inflate to block the blood flow through  your artery. Next, the deflation process starts. When  measurement is complete, the monitor will display  Date/Time  your systolic pressure, diastolic pressure, and pulse  Set Buttons LCD Display readings. Please note that any muscle movement  during inflation or deflation will cause measurement  error.  Battery  The monitor automatically finds where your  Cov
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Display	 Symbols: DISPLAY EXPLANATIONS User	 1:  Appears when the monitor is operated by  User 1 User	 2:  Appears when the monitor is operated by  User 2 Weak	 Battery	 Symbol:  Appears when batteries  should be replaced Pulse	 Symbol: Shows the heart rate per minute Irregular	 Heartbeat	 Detector: Refer to page 28 for  Systolic  more information. Pressure Memory	 Average: Displays average of last 3  readings AVG. 3 AVG. 3 AVG. 3 Risk	 Category	 Index: See page 27 for more  information START M 
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        1. INSTALLING BATTERIES Replace	 the	 batteries	 if: 1. The  weak battery symbol appears on the display.	 1. T he battery cover is located  2. Nothing  appears on the display when the power is  along the side of the monitor.  switched on. Remove battery cover by  pressing down and pulling  As the supplied batteries are for test only, they may  away from the monitor. 2. be discharged earlier than batteries you buy in stores.  Replace all batteries at one time (as simultaneous set).  2.  Install b
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        DATE & TIME SET PROCEDURE APPLYING THE CUFF 1. T o adjust the date/time, press the Set	 button     1.  Remove all watches, wrist jewelry, etc. prior to  located on the top of the monitor.  attaching the wrist monitor. Clothing sleeves  should be rolled up and the cuff should  2. The display will show a blinking number showing  be wrapped around bare skin for correct  the HOUR. Change the HOUR by pressing the  measurements.  button. Each press will increase the number  by one in a cycling manner.
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        4. In  order to insure accurate  CORRECT MEASUREMENT POSTURE Fig. C measurements, fasten the  hook and loop strap securely  1. Place  your elbow on a table  around your wrist so there is  so that the cuff is at the same  no extra space between the Fig. A level as your heart as shown in  cuff and the wrist as shown  Fig. A. Relax your entire body,  in Fig. C.  If the cuff is not  especially between your elbow  wrapped tight enough, the  and fingers.   measurement values will not  Fig. D Note: You
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        3. Turn your palm upwards. MEASUREMENT PROCEDURE Fig. C Important	 Notes: (X) 4. Sit  upright in a chair, and take  •  Position the monitor at the same level as your  5-6 deep breaths. heart during measurement to ensure accurate  Note: Avoid leaning back  readings. while the measurement  is being taken as  •  Blood pressure changes with every heartbeat and  shown in Fig. C. is in constant fluctuation throughout the day. •  Blood pressure measurement can be affected  by the position of the user, 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        •  During the measurement, do not talk or move your 2.  W ith the cuff wrapped around your wrist, press the  arm or hand muscles. START/STOP	 button. Do not inflate the cuff unless  AVG. 3 AVG. 3 AVG. 3 it is wrapped around your wrist. All digits will light  •  See page 33 for additional notes regarding your  up, checking the display functions. The checking  AVG. 3 AVG. 3 blood pressure measurement. procedure will be completed after about 3 seconds. If you are using this blood pressure monitor f
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Note: The monitor will re-inflate automatically if Note: the system detects that your body requires  1.  This monitor automatically turns off approximately  more pressure for measurement. 1	 minute after last operation. You may also press  the START/STOP	 button	 to turn the unit off. 2.  To interrupt the measurement, you may press  the START/STOP	 button	 (recommended),  “M”,	 User-Select	 or	 Date/Time	 Set	 ( /	 )	 buttons.	 The cuff will deflate immediately after a  button is pressed. 4.  Wh
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        RISK CATEGORY INDEX IRREGULAR HEARTBEAT DETECTOR (IHB) This monitor comes equipped with a Risk Category  Index that automatically compares each reading  The appearance of the  icon indicates that  to defined levels established by the U.S. National  a pulse irregularity consistent with an irregular  Institutes of Health’s (NIH) National Heart Lung and  heartbeat was detected during measurement. Usually  Blood Institute as described earlier in this manual,  this is not a cause for concern. However
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        IRREGULAR HEARTBEAT DETECTOR (IHB),  RECALLING VALUES FROM MEMORY CONTINUED To determine the presence of an irregular heartbeat,   This monitor can be used by two individuals. Each	 user	 the average of the heartbeat intervals is calculated  can	 store	 up	 to	 60	 measurements. with the first 3 normal effective heartbeat values. It  is important to note that the average is not a strict  1.  Press the User-Select	 button. mathematical averaging of all recorded intervals. At  least 3 beats with 2
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        4. T he	 monitor	 will	 first	 display	 the	 calculated	 average	 CLEARING VALUES FROM MEMORY applied	 to	 the	 last	 3	 memories	 (“AVG.	 3”).	 1.   Press  the User-Select	 button to select User 1 or  User 2. START M STOP AVG. 3 AVG. 3 AVG. 3 M START STOP 2.   Press  and hold the  and  buttons at the same  time while in memory recall mode and the data for  5.  Every new press of the “M”	 button will recall  the selected user will be erased automatically. a previous reading. The latest reading w
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        •   This	 product	 is	 not	 suitable	 for	 people	 with	 IMPORTANT NOTES REGARDING YOUR  arrhythmias.		 BLOOD PRESSURE MEASUREMENT •	 	 This	 device	 may	 have	 difficulty	 determining	 the	 •   Take your reading in a comfortable environment  proper	 blood	 pressure	 for	 pregnant	 women	 and	 as measurements can be affected by hot or cold  for	 users	 with	 irregular	 heartbeat,	 diabetes,	 poor	 temperatures. Take your blood pressure at normal body  circulation	 of	 blood,	 kidney	 problems,	 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        6.    Do not immerse the unit in water as this will result in  POTENTIAL FOR ELECTROMAGNETIC  damage to the unit. INTERFERENCE	 7.   Do   not subject the monitor and cuff to extreme  To avoid inaccurate results caused by  temperatures, humidity, moisture, and direct sunlight.  electromagnetic interference between  Protect from dust. electrical and electronic equipment, do  8.   Do not fold the cuff tightly. not use the device near a cell phone or  9.   Do  not disassemble the monitor or cuff.  I
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        installation. If this equipment does cause harmful interference  TROUBLESHOOTING to radio or television reception, which can be determined by  If any abnormality arises during use, please check the following points: turning the equipment off and on, the user is encouraged to  POSSIBLE	 	 SYMPTOMS CORRECTION try to correct the interference by one or more of the following  CAUSES measures:  Unit does not turn Batteries have  Replace them   on when the START/ run down. with two new AAA  • Reorient 
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        SPECIFICATIONS SPECIFICATIONS (continued) Power	Source: Two 1.5V DC (AAA) Alkaline batteries  Weight: 0.30 lbs (136.1 g) (without batteries) Measurement	 Wrist	 Oscillometric 5.3” - 7.7” (13.5cm - 19.5cm) Method: Circumference: Measurement	 Pressure:  40~280 millimeters Mercury (mmHg) Two AAA alkaline batteries, instruction  Accessories: Pulse: 40~199 beats/minute Range: manual, hard plastic storage case Pressure: ±3 mmHg 2.6”(L) x 1.3”(W) x 3.1”(H)  Accuracy: Dimensions: Pulse: ±5% of reading 6