ملخص المحتوى في الصفحة رقم 1 
                    
                         
CARPET EXTRACTOR 
Operating Instructions 
MODEL: ADM8 
  10080170 
Read these instructions before operating the machine
RR 
86038320  03/16/07 
 
PRV NO. 98628                                                                                                                                                                                                                                                                                                                                                   
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        MACHINE DATA LOG/OVERVIEW          MODEL  _______________________________________                        DATE  OF  PURCHASE  __________________________             SERIAL   NUMBER  ______________________________                                                     SALES REPRESENTATIVE  #  _____________________              DEALER   NAME  ________________________________       OPERATIONS GUIDE NUMBER  ___________________              PUBLISHED  __________________________________________           
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        TABLE OF CONTENTS    Machine Data Log/Overview................................1  Table of Contents.................................................2    HOW TO USE THIS MANUAL    How to use this Manual........................................1-1    SAFETY    Important Safety Instructions ...............................2-1  Hazard Intensity Level..........................................2-2  Grounding Instructions.........................................2-3    OPERATIONS    Technical Specifications
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        HOW TO USE THIS MANUAL      The SAFETY section contains important information  This manual contains the following sections:  regarding hazard or unsafe practices of the    machine. Levels of hazards is identified that could  - HOW TO USE THIS MANUAL  result in product or personal injury, or severe injury  - SAFETY  resulting in death.  - OPERATIONS    - MAINTENANCE  The OPERATIONS section is to familiarize the  - PARTS LIST  operator with the operation and function of the    machine.  The HOW TO
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        HAZARD INTENSITY LEVEL    The following symbols are used throughout this guide as indicated in their descriptions:     HAZARD INTENSITY LEVEL  There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR  SAFETY. The level of hazard intensity is determined by the following definitions:          !   WARNING   WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.    ! CAUTION   CAUTION - Hazards or unsafe practices which 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        GROUNDING INSTRUCTIONS  THIS PRODUCT IS FOR COMMERCIAL USE ONLY. PROPER GROUNDING   Grounding Pin Metal Screw ELECTRICAL:  In the USA  this machine operates on a standard 15  amp 115V, 60 hz,  A.C. power circuit . The amp,  hertz,  Grounded Adaptor Outlet and voltage are listed on the data label found on each  Grounded Outlet Box Fig. A machine.  Using voltages above or below those  Fig. B Tab For Grounding Screw indicated on the data label will cause serious damage  to the motors.   Adaptor   F
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        TECHNICAL SPECIFICATIONS  POWER TYPE GENERAL DIMENSIONS/WEIGHT     ELECTRICAL:  115 V, 15 A, 60 HZ Vacuum shoe:  17” (43.18 cm) cast   aluminum with spring loaded down pressure  ELECTRIC VACUUM MOTOR:  (1) –3 stage, 1 hp, 99 cfm   (2.80 cubic meters/min.) Waterlift –117” (297cm) WHEELS:  (2) 10” dia. (25 cm) wheels by 2”     BRUSH:  (1) 15” (38.1 cm.) WEIGHT:  92 lbs. (42 kg)     SOLUTION PUMP:  100 PSI, diaphragm style, internal LENGTH:  35” (89 cm)  bypass    HEIGHT:  42” (107 cm)  SOLUTION CA
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        CONTROLS/COMPONENT LOCATIONS  1. Main Handle.  Used to pull and maneuver  4 5 6  8 9  machine.    2. Handle Adjustment.  Used to adjust height  of handle.    3. Electrical Cord.    4. Solution Switch. Turns on pump.  Continuous position (bottom) activates  electro-valve to dispense solution to floor  through jets. Intermittent position (up)  requires operator to depress 1 of 3 trigger  switches to dispense solution. Center  7 position is off.    5. Brush Motor Switch.  Turns on brush  motor.    
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        CONTROLS/COMPONENT LOCATIONS  1. Solution Accessory Tool Hookup.  Used for  various auxiliary cleaning tools.    2. Vacuum Hose Door.  Used to connect various  auxiliary 1 ½ inch cleaning tool vacuum hoses.    11  3. Brush Height Adjustment.  Used to regulate  brush height from storage position to various  carpet heights.    10 4. Recovery Tank.  Used to collect dirty cleaning  solution.    5. Solution Tank.  Used to hold cleaning solution.    6. Recovery Tank Dome.    7. Vacuum Shoe.   1 8. Bru
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        CONTROLS/COMPONENT LOCATIONS  1. Solution Intake Cover.     2. Vacuum Intake Cover.    3. Float Shut-Off.    4. Clean-Out Opening.    5. Pour Spout.    6. Lift Handle.  6 1 2  4  6  5 3  ADMIRAL  86038230  03/16/07  3-4                                                                                                                                                                                                                                                                                         
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        FILLING OPERATIONS   STEP   1    RECOVERY TANK      Remove recovery    tank        SOLUTION    TANK                STEP Add water    2  or 8 gal.    (30.3 ltr.)               140°F (60°C)   FILL LINE      STEP   3   8 – 16oz.  FILLING THE ADMIRAL  (237ml – 473ml) NOTE: Use clean bucket of water to fill solution tank    Add cleaning  Do not put defoamer, solvents, spotter or   chemical  prespray chemicals in the solution tank.    Do not allow water to spill into vacuum motor inlet.    Dry spillag
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        OPERATIONS  Remove electrical cord and literature from  STEP   recovery tank. Fill solution tank (see filling  1 instructions page 3-5).  Plug cord into grounded outlet. Note: Be sure  STEP dome is seated on recovery tank, and float  2 shut-off is installed correctly.  Adjust brush to proper setting.  Note: For  STEP good operation the brush must skim the  3 carpet.  If circuit breaker trips raise brush to  1/8in prevent damage to motor or carpet.  (3mm) CORRECT  INCORRECT  Turn on brush and vac
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        OPERATIONS  Adjust handle to comfortable operating STEP position. Tip machine back by main handle 5 to move to starting point.    Lower machine to floor. STEP 6 Select continuous setting to start solution STEP spray or select intermittent setting to 7 enable use of trigger switches to start  solution spray.  The intermittent setting requires the  INT operator to hold any one of the three  trigger switches in the “on” position with the  CONT  fingers, and is typically used in small areas  where s
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        CLEANING PROCEDURE  Start at wall closest to power outlet. Pull  STEP straight back without pushing down on    1 handle.  Release intermittent trigger switches or  STEP turn off continuous setting on solution  2 switch approximately 1 foot before ending  cleaning pass.  1ft.  (30cm)  OFF  Push down on handle to raise vacuum  STEP shoe and brush before moving to the next  1in.  3 cleaning pass.  Overlap brush contact  (25mm)  area approximately 1inch.  During operation, observe the following: The
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        CLEANING PROCEDURE  Use right side of machine for cleaning STEP   against walls. 5 After cleaning, turn off all controls, return STEP brush to storage position and carefully 6 unplug machine.  OFF  OFF OFF  To speed drying, use a Windblower ™ fan. STEP 7 Empty recovery tank by releasing dump STEP hose.  Use a hose with cold water to clean 8 out the recovery tank.  Also drain solution  tank after each use.  RECOVERY  DRAIN SOLUTION  DRAIN ADMIRAL  86038230  03/16/07  3-9                          
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        ACCESSORY TOOL USAGE  Use only one of the following acceptable  STEP accessory tools.  APRV NO.  1   HT – 86000610 PRV NO. 89227   DDH – 86000060 PRV NO. 89226  DH – 86031540 PRV NO. 39504    Pull back collar and insert over machine  mounted fitting, then release collar to lock  into place.  Lift door on front of vacuum shoe and insert  STEP 1 ½ inch hose cuff into hole.  2 Turn on vacuum motor switch and set  STEP solution switch to intermittent position.   3 Note: Be sure brush switch is in of
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        MAINTENANCE  SERVICE SCHEDULE    MAINTENANCE DAILY WEEKLY QUARTERLY    Check machine for cord damage *    Check recovery dome and gasket for  damage and cleanliness *    Check brush – should be clean with no  lint or strings attached *    Inspect vac shoe for blockage; remove  fibers with coat hanger, etc. *    Check hoses for wear, blockages, or  damage *    Check handles, switches, and knobs  for damage *    Check vac motor intake filter and clean *    Run one gallon of water through   system 
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        MAINTENANCE    PERIODIC  MAINTENANCE  7. Remove lint and dirt build-up from brush and  Twice a month, flush a white vinegar solution (One  housing.  quart vinegar to two gallons of water) or anti- NOTE: Brush removal.  browning solution (mixed as directed) through the  A. To remove brush, grab and pull brush out  extractor. This will prevent build-up of alkaline  from end opposite drive belt (operator’s  residue in the system. If spray jets become clogged,  right). Remove other end from brush dr
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        MAINTENANCE  ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE  FOLLOWING REPAIRS.  ! WARNING:     VACUUM MOTOR REPLACEMENT  Vacuum Motor Carbon Brushes Replacement (Ametek)  1. Turn off all switches and unplug machine.  End Cap  2. Remove recovery tank.  WARNING: The green  Carbon   3. Remove the (2) screws that fasten the solution tank to  ground wire must be  Brushes   the frame, and tilt tank back to expose the inside of the  attached for safe operation.  frame. See wiring diagram.  4.