WM+PD4000273D                                                                                                                                                                                                                                                                                                                                 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                            © 2006 A&D Company Ltd. All rights reserved.  No part of this publication may be reproduced, transmitted, transcribed, or translated  into any language in any form by any means without the written permission of A&D  Company Ltd.      The contents of this manual and the specifications of the instrument covered by this  manual are subject to change for improvement without notice.                                                                                                                    
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                          CONTENTS  Basic operation  1. INTRODUCTION ............................................................................................................................ 3  1-1 About This Manual ..............................................................................................................................3  1-2 Features ..............................................................................................................................................3  1-3 Compliance ...
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                          9-8 Data Format Examples .....................................................................................................................46  9-9 Clock and Calendar Function............................................................................................................48  9-10 Comparator Function ......................................................................................................................50  9-11 Adding the Comparison Results............................
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                          1. INTRODUCTION  This manual describes how the GP series balance works and how to get the most out of it in terms  of performance.   Read this manual thoroughly before using the balance and keep it at hand for future reference.    1-1 About This Manual  This manual consists of the following five parts:  Basic operation..............................Describes precautions on handling the balance, balance  construction and basic balance operation.   Adapting to the environment..........Describes r
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                           Hold Function, provided for weighing a moving object such as an animal.   Multiple Weighing Units, with most of the common units used around the world.   Density Mode, for calculating the density of a solid.   Accumulation Function, adding the weight values and outputting the sum.   Adjustable Display Position, the standard type balance has a swing-arm to adjust the display  position for optimum viewing.      Separate display type balances (GP-30KS/32KS/60KS/61KS/100KS) are also available.   
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                          1-3 Compliance  Compliance with FCC Rules  Please note that this equipment generates, uses and can radiate radio frequency energy. This  equipment has been tested and has been found to comply with the limits of a Class A  computing device pursuant to Subpart J of Part 15 of FCC rules.  These rules are designed to  provide reasonable protection against interference when equipment is operated in a  commercial environment. If this unit is operated in a residential area, it may cause some  interfe
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                                                                                                          6                                                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                          2. UNPACKING THE BALANCE  2-1 Unpacking   The balance is a precision instrument. Unpack the balance carefully. Keep the packing  material to be used for transporting the balance in the future.   The packing contents depend on the balance model. See the illustrations to confirm that  everything is contained.  Standard type: GP-12K/20K/30K/32K/40K/60K/61K/100K/102K                                                                 Note  Please confirm that the AC adapter type is correct   for your 
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                          Separate display type: GP-30KS/32KS/60KS/61KS/100KS                                                               Note  Please confirm that the AC adapter type is correct   for your local voltage and receptacle type.    2-2 Installing the Balance  Install the balance as follows:  1. Refer to “3. PRECAUTIONS” for installing the balance.   2. Adjust the leveling feet to level the balance. Confirm it using the bubble spirit level.  3. Confirm that the adapter type is correct for the local voltage
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                          3. PRECAUTIONS  To get the optimum performance from the balance and acquire accurate weighing data, note the  following:    3-1 Before Use   Install the balance in an environment where the  temperature and humidity are not excessive. The best  operating temperature is about 20°C / 68°F at about  50% relative humidity.   Install the balance where it is not exposed to direct sunlight  and it is not affected by heaters or air conditioners.   Install the balance where it is free of dust.   Install
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                           This balance uses a strong magnet as part of the  balance assembly, so please use caution when  weighing magnetic materials such as iron. If there is a  problem, use the underhook on the bottom of the  balance to suspend the material away from the  influence of the magnet.   Cancel the temperature difference between a sample  and the environment. When a sample is warmer  (cooler) than the ambient temperature, the sample will  be lighter (heavier) than the true weight. This error is  due to a 
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                          3-5 Display Symbols and Key Operation  Key operation  Key operation affects how the balance functions. The basic key operations are:   “Press and release the key immediately” or “Press the key”      = normal key operation during measurement   “Press and hold the key”        Display symbols                                      Each key, when pressed or when pressed and held, functions as follows:  Key When pressed When pressed and held   Turns the display ON and OFF. The standby indicator is di
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                          3-6 Smart Range Function  The GP-32K, GP-32KS and GP-102K are equipped with two ranges. The precision range has a  higher resolution. The standard range has normal resolution.  The range is switched automatically, depending on the value displayed. Pressing the RE-ZERO key  allows weighing in the precision range, regardless of the tare value. (Smart range function)  The range can be fixed to the standard range, by pressing the SAMPLE key.  Note  Once the range is switched to the standard range,
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                          4. WEIGHING UNITS  4-1 Units  With the GP series balance, the following weighing units and weighing modes are available :                      A unit or mode can be selected and stored in the function table as described in “4-2 Changing the Units”.  If a weighing mode (or unit of weight) has been turned off, that mode or unit will be missing in the  sequence. Tael has four varieties, one of which can be selected and installed at the factory.  For details about the units and modes, see the tabl
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                          The tables below indicate the weighing capacity and the minimum display for each unit, depending  on the balance model.     Unit GP-12K GP-20K GP-30K GP-61K GP-40K  Minimum Minimum  GP-30KS GP-61KS  display display Capacity Capacity  Gram 12000.0 21000.031000.061000.0 0.141000.0 0.5 Kilogram 12.0000 21.000031.0000 61.0000 0.0001 41.0000 0.0005 Ounce (Avoir) 423.290 740.755 1093.495 2151.710 0.005 1446.24 0.02 Pound 26.4555 46.297068.3435 134.4820 0.0005 90.390 0.002 Pound/Ounce 26L  7.29 46L  
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                                             Unit GP-32K/ GP-32KS  Standard range Precision range  Capacity Minimum display Capacity Minimum display  Gram 31000 16100.0 0.1 Kilogram 31.000 0.0016.1000 0.0001 Ounce (Avoir) 1093.50 0.05 215.170 0.005 Pound 68.345 0.00513.4480 0.0005 Pound/Ounce 68L  5.5 0.1 13L  7.17 0.01 Troy Ounce 996.65 0.05 196.120 0.005 Metric Carat 155000 5 30500.0 0.5 Mom me 8266.5 0.5 1626.65 0.05 Pennyweight 19933 1 3922.4 0.1 Tael (HK general,  820.10 0.05161.380 0.005 Singapore)  Tael (HK jewe
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                          4-2 Changing the Units  The units or modes can be selected and stored in the function table. The sequence of displaying the  units or modes can be arranged so as to fit the frequency of use in the function table.     Select a unit or mode and arrange the sequence of display as follows:  1 Press and hold the SAMPLE key until ba5fnc of the  function table is displayed, then release the key.  2 Press the SAMPLE key several times to display   Unit .  3 Press the PRINT key to enter the unit selecti
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                          5. WEIGHING  5-1 Basic Operation (Kilogram Mode)  1 Place a container on the weighing pan, if necessary.    Press the RE-ZERO key to cancel the weight (tare). The  balance displays  0.0000 kg. (The decimal point position  depends on the balance model.)  2 Place a sample on the pan or in the container.  3 Wait for the stabilization indicator to be displayed. Read  the value.  4 Remove the sample and container from the pan.  Notes  To use another unit, press the MODE key and select an  appropria
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                          5-2 Counting Mode (PCS)  This is the mode to determine the number of objects in a sample based on the standard sample unit  mass. Unit mass means the mass of one sample. The smaller the variables in each sample unit  mass is, the more accurate the counting will be. The GP series balance is equipped with the  Automatic Counting Accuracy Improvement (ACAI) function to improve the counting accuracy.  Note  If the sample unit mass variable, the difference from sample to sample, is too large, it ma