ملخص المحتوى في الصفحة رقم 1 
                    
                        C
N
E
R
G
T
I
INSTALLER / CONSUMER 
SAFETY INFORMATION
PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE.
WARNING! Radiance
IF THE INFORMATION IN THIS 
MANUAL IS NOT FOLLOWED 
Direct Vent/Natural Vent 
EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT CAUSING PROPER-
Gas Heater
TY DAMAGE, PERSONAL INJURY 
Model RDVOD: 3350 thru 3354, 
OR LOSS OF LIFE.
3360 thru 3369, 3390 thru 3399 
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service 
agency or the 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Table Of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT:  Read all instructions and warnings carefully before starting installation.  Failure to follow these  instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions  .....................................................
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Installation & Operating Instructions The Radiance Direct Vent/Natural Vent Room Heater, factured (mobile) home, where not prohibited by state or local  Model  Nos. 3350 thru 3354, 3360 thru 3369 and 3390 thru codes.  3399, is a vented gas appliance listed to the ANSI standard WARNING: Operation of this heater when not con- Z21.88b-2002  and CSA-2.33b-2002 for Vented Room Heat- nected to a properly installed and maintained venting  ers, and  CSA 2.17
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Radiance Direct Vent/Natural Vent Stove Dimensions See Page 6 for Flue Collar  14 ���" 7" Outer Dia. Centerline Dimensions. (3.7cm) (1.8cm) 4 ���" (1.2cm) � ����������� � 29���" (7.6cm) � � � � � � � � 28" (711mm) Supply Inlet 5" (127mm) 9���" 31" (241mm) (7.9cm) 18���" 4188 (464mm) Fig. 1  Radiance dimensions. ST126 RDV40 dimensions Attention 10/99 The Radiance stove is shipped from the factory as a Direct Vent Gas Heater. This heater may be convert
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Installation Requirements The installation must conform with local codes or, in  the absence of local codes, with the National Fuel Gas  Direct Vent System Only Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP- TION:  Do not derate this appliance for altitude.  Main- tain the manifold pressure at 3.5” w.c. for Natural Gas,  and 10” w.c. for Propane). A D In Canada, installation must be in accordance with the  B current CSA B-149.1 Installation Code
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Parallel Installation: Minimum Clearance Wall Centerline from Floor and Flue Centerline, Direct Vent and Natu- Direct Vent Only ral Vent 42" (1070mm) Min. Alcove Width 4" (102mm) 48" (1220mm) Max. Alcove  Depth A 6" 6" ST130 (150mm) (150mm) Fig. 3  Parallel installation, minimum back and side clear- ances, and flue centerlines. ST131b �����  A Corner Installation: Minimum Clear- ���� � ������� Effective Minimum ����� ance and Flue Centerline, Direct V
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Horizontal Termination -  Gas Specifications Direct Vent ONLY     Max. Min. The vent must rise vertically a minimum of 24” (610mm)      Input Input off the top of the unit, before the first elbow. The hori-  Model Fuel Gas Control BTU/h BTU/h zontal run may extend up to 20’ (6m) and include a   RDVODRN Nat Millivolt 35,000 25,000 vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termi-  RDVODRP Prop Millivolt 35,000 27,500 nation must also meet the
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  Vertical Termination - Direct Vent ONLY Vent Termination Clearances A vertical vent system must terminate no less than 8’  When planning the installation, consider the location  (2.44m) and no more than 40’ (12m) above the appli- of the vent terminal and clearances. Some of the most  ance flue collar. A 2 ¹⁄₄" restrictor plate (supplied) must  common clearances to keep in mind are shown in Figure 9.  be used, where specified, in all vertically terminat
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Vent Termination Clearances Your stove is approved to be vented either through the  There must not be any obstruction such as bushes,  side wall, or vertical through the roof. garden sheds, fences, decks or utility buildings within  24” from the front of the termination hood. • CFM Specialty Home Products does not require  any opening for inspection of vent pipe. Do not locate termination hood where excessive snow  or ice build up may occur. Be sure 
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        V V �������� Radiance Direct Vent/Natural Vent Gas Heater  General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E B C B ����� ����� V L B V ������ ������ V ����� �������� G ������ F V V B M V G B X J B I K X V V A A AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION X AIR SUPPLY INLET V CFM145a 1 2   Canadian Installations US Installations  A = Clearance above grade, veranda, porch,  12” (30cm)  12” (30cm) CFM145a DV Termin Location   deck, or balcony 5/01/01 
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.  Inside Corner Outside Corner Recessed Location D B = C C Combustible  A =   6"(152mm) E Combustible  A   6"(152mm) Noncombustible  V V   2"(50mm) Noncombustible    2"(50mm) V B Balcony - Balcony -  with no side wall with perpendicular side wall C = Maximum depth of 48"        (1219mm) for recessed  H G        location.         V V D = Minimum w
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  (1) 24” - 42” Adjustable Straight Pipe Venting Requirements and Options -  (1) Side Wall Termination Direct Vent ONLY (1) Firestop Approved Vent System Components (1) Zero-clearance sleeve The Stardance Heater must be vented to the outdoors (1) Hardware package through an adjacent exterior wall or through the roof. The (1) Finishing plate (CG) venting system must be comprised of the appropriate (1) Finishing collar (CG) listed venting components spec
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Assembly Procedures   WARNING Failure to position the parts in accor- dance with these diagrams or failure to  use only parts specifically approved for  use with this heater may result in property dam- age or personal injury. This heater and components are heavy. Have  help available for assembly. Tools Required •  Phillips screwdriver (stub) •  power drill •  utility knife   •  reciprocating saw ST720 •  metal drill bit:  size 28 (.140”/3.5mm)  Fig. 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  WARNING This appliance is equipped with a three-prong  (grounded) plug for your protection against shock  hazard and should be plugged directly into a  properly grounded three-prong receptacle. Do not  cut or remove the grounding prong from this plug. Install the Optional Fan If  you are installing the optional convection Fan Kit  #2767 (FK26), continue here. It is easiest to install fan  kit before connecting gas line. If you are not installing a  F
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater 4. Attach the Inner Vent Assembly to the stove. Venting System Assembly - Direct Vent •  Run a bead of sealant around the bottom end of  General Information the starter pipe and attach the assembly to the stove  The Radiance is approved for installation only with the  using three 1/4-20 x 3/8” Phillips screws provided in  vent components listed on Page 11. Follow the vent  the parts bag. (Fig. 20) component instructions exactly. 5. Install the Outer 
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  ST651 ST650 Fig. 23  Simpson Dura-Vent - install outer adapter pipe.  Fig. 21   Fasten outer pipe with #12 x 1/2” sheet metal screw. Side Wall Termination Assembly Install the Vent Adapter Pipe  1. Locate the vent opening on the wall. Refer to Page  (Simpson Dura-Vent Components) 6, Figure 5, to determine the opening centerline.  It may be necessary to first position the stove and  1. Install the Restrictor Plate. Consult Page 7 to de- measure to find 
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater 6. Install the elbow using 3 sheet metal screws at each  12” joint.  (305mm)  Sleeve Max. Length 7. Measure, and cut if needed, the appropriate length  of pipe section needed to make the connection  through the wall. Include a 2” overlap; i.e. from the  elbow to the outside wall face, about 2” or the dis- tance required if installing a second 90° elbow. (Fig.  #8 Sheet  27) Metal Screws 8. Slip the wall plate and trim collar over the interior  end of
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  11. For CFM only: Install Charcoal Gray Pipe Rings  (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP)  Recessed Wall at pipe joints, if desired. Firestop Seal Both Termi- nal Ends Finishing  Sheet Metal  Collar Screws and  Bracket Wall Screws  and Anchors Waterproof Seal  Around Pipe 7” Pipe Wall Plate ST219 Caulk Plate Joint with  ST217 Weatherproof Sealant Fig. 30  Use extension brackets to mount snorkel against  Fig. 29  Install the vent terminal. 
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Radiance Direct Vent /Natural Vent Gas Heater Make certain the vent system conforms to all other  requirements for vertical termination as specified on  Use three #5  Page 9. sheet metal  screws at  This installation will require you to first determine the  each joint roof pitch and use the appropriate vent components.   Refer to Figure 9 on page 9. Sealant Storm Collar 1. Locate the final position of the stove, observing all  clearances for both the vent and the stove. 2. Plumb to the center of th
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Radiance Direct Vent/Natural Vent Gas Heater  The Radiance stove, when installed as a Natural vent  Install Log Set heater, includes a vent safety switch. (Page 34, Figure  67) Operating the stove when it is not connected to a  Before beginning log installation, remove stove front  properly  installed and maintained venting system, or  and glass frame. Refer to Figures 36 and 37. tampering with or disconnecting the vent safety switch,  can result in carbon monoxide (CO) poisoning and  possible d