ملخص المحتوى في الصفحة رقم 1 
                    
                        VENTED DECORATIVE GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
HARDWOOD ORIGINAL CALIFORNIA MAPLE KENTUCKY ELM
 HCA-18-RFN HCM-18-RFN HKE-18-RFN
 HCA-24-RFN HCM-24-RFN HKE-24-RFN
 HCA-18-RFP HCM-18-RFP HKE-18-RFP
 HCA-24-RFP HCM-24-RFP HKE-24-RFP
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicini
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation  and operational procedures. For assistance or addi- tional information consult a qualified installer, service  agency or the gas supplier. WARNING: This appliance is for installation only in  a solid-fuel burning masonry or UL127 factory-built  fireplace, constructed of noncombstible material and  connected to a working flue. (See pag
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        SAFETY INFORMATION  WARNING: This appliance  is equipped for (natural or pro-  WARNING: This product con- pane/LP) gas. Field conversion  tains and/or generates chemicals  is not permitted. known to the State of California  to cause cancer or birth defects   WARNING: Do not allow fans  or other reproductive harm. to blow directly into the fireplace.  Avoid any drafts that alter burner   WARNING: Keep flue open  flame patterns. when operating unit.  WARNING: Installed decora- IMPORTANT: Read this ow
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        10. Log set becomes very hot when in use. Keep  SAFETY INFORMATION children and adults away from hot surface to  Continued avoid burns or clothing ignition. Log set will  remain hot for a time after shutdown. Allow  Children and adults should be  surface to cool before touching. alerted to the hazard of high tem- 11. Carefully supervise young children when they  perature and should stay away to  are in the room with the log set. avoid burns or clothing ignition. 12. Do not use heater if any part
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        UNPACKING  CAUTION: This heater creates   CAUTION: Do not remove the warm air currents. These currents  data plates from the grate as- move heat to wall surfaces next  sembly. The data plates contain  to heater. Installing heater next  important warranty and safety  to vinyl or cloth wall coverings or  information. operating heater where impurities  (such as, but not limited to, to- 1. Remove log set assembly from carton.  bacco smoke, aromatic candles,  2. Remove all protective packaging applie
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        PLACEMENT OF APPLIANCE INSTALLATION Center the appliance in the fireplace. Make certain  Continued  the grate front feet sit inside the front edge of  VENTING SPECIFICATIONS FOR  the fireplace and that there is adequate clearance  INSTALLATION around the appliance for access and operation. The fireplace chimney flue and vent must be draft- CONNECTING TO GAS SUPPLY ing properly. To check the vent for proper drafting:  Light a tightly rolled newspaper on one end and   WARNING: A qualified service  plac
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Approved Flexible  INSTALLATION CSA Design-Certified  Gas Hose (If  Continued  Equipment Shutoff Valve  allowed by local  with 1/8" NPT Tap* The appliance gas inlet connection is 3/8" NPT at codes) the regulator, located at the rear of the appliance. IMPORTANT: Hold appliance regulator with a  Natural  wrench to prevent movement when connecting  From Gas  to inlet piping. Meter (5" W.C.**  to 10.5" W.C.  Pressure)  CAUTION: Use only new,  3" Minimum black iron or steel pipe. Inter- nally-tinned c
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Equipment  INSTALLATION Shutoff Valve Continued  4. Check all joints of gas supply piping system.  Apply noncorrosive leak detection fluid to all  Gas Meter joints. Bubbles forming show a leak.  5. Correct all leaks at once. 6. Reconnect heater and equipment shutoff  valve to gas supply. Check reconnected fit- tings for leaks.  Control Valve  Location Test Pressures Equal To or Less Than  1/2 PSIG (3.5 kPa) Figure 7 - Checking Gas Joints   1. Close equipment shutoff valve (see Figure 5). (Natural 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        INSTALLATION Continued  3. Place fiber log pieces randomly on lava rock and  ember material around unit (see Figure 10). 4. Use remaining lava rock to blend the floor  media together. Your finished effect should  resemble Figure 11.  WARNING: Failure to posi- Figure 11 - Floor Media Kits Installed tion the floor media as shown in  Figures 8 through 11 or failure  OPERATING APPLIANCE to use only parts specifically  The RF Millivolt valve control used on these appli- approved with this appliance  ances
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        OPERATING HEATER LIGHTING  Continued   INSTRUCTIONS FOR YOUR SAFETY  NOTICE: During initial operation  READ BEFORE LIGHTING the appliance will emit a slight  odor for an hour or two. This is   WARNING: Keep flue open  due to the "burn-in" of the inter- when operating unit. nal paints and lubricants used  in manufacturing. For the first  few hours, operate the appliance   WARNING: If you do not fol- with doors and windows open to  low these instructions exactly,  encourage dissipation of odor. a fir
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        OPERATING HEATER Continued  4. Press MODE  button until mode  shows in display window of transmitter/ remote. Press up or down key to change  set temperature. 5. To set delay timer, press TIMER  button  followed by either the up or down key. 6. To change the flame height, press the  MODE  button until mode is ON. Press  Figure 13 - Correct Pilot Flame Pattern the FLAME button and press the up or  down arrow key. 7. To change between Fahrenheit and Celsius,  press the up and down arrow keys at th
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        CLEANING AND TECHNICAL SERVICE You may have further questions about installation,  MAINTENANCE operation or troubleshooting. If so, contact DESAʼs  Technical Service Department at 1-866-672-6040.   WARNING: Turn off the ap- When calling please have your model and serial  pliance and allow to cool before  numbers of your heater ready. cleaning. You can also visit DESAʼs technical services web  site at www.desatech.com.  CAUTION: You must keep  REPLACEMENT PARTS control areas, burners and  Note: U
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        TROUBLESHOOTING LED Failure Code Note: In normal operation, LED blinks once  (No. of Blinks) Service Action every two seconds; also, LED will be on for one   8 Replace valve. second after every valid command received by the  receiver/valve' these are not error codes. 7 Confirm stepper motor     connection exists. Failure codes can occur anytime after the pilot  burner is lit. Failure code timing is 1/4 second  5 Confirm fan connection     exists and works. on, 1/2 second off. Sequence is failure c
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Pilot burning, no gas to burner, 1. Wall switch or wires 1. Check wall switch and wires  valve knob "ON", wall switch defective for proper connections. Jump- "ON" er wire across terminals at wall  switch. If burner comes on,  replace defective wall switch.  If okay, jumper wires across  wall switch wires at valve. If  burner comes on, wires are  faulty or connections are bad 2. Thermopile may not be 2. Check thermopile with mil- ge
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        SPECIFICATIONS   HCA-24-RFN HCA-24-RFP HCA-18-RFN HCA-18-RFP   HCM-24-RFN HCM-24-RFP HCM-18-RFN HCM-18-RFP   HKE-24-RFN HKE-24-RFP HKE-18-RFN HKE-18-RFP Btu (Variable) 45,000/67,000 43,000/65,000 41,000/56,000 42,000/51,000  Type Gas Natural Gas Only Propane/LP Only  Natural Gas Only Propane/LP Only Ignition Piezo Piezo Piezo Piezo Manifold Pressure 3.5" - 1.6"W.C. 10" - 6.3"W.C.  3.5" - 1.6"W.C. 10" - 6.3"W.C.  Inlet Gas Pressure (in. of water)  Maximum 10.5" W.C. 13" W.C. 10.5" W.C. 13" W.C.  
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        ILLUSTRATED PARTS BREAKDOWN HCA-24-RFN, HCA-24-RFP, HCA-18-RFN, HCA-18-RFP, HCM-24-RFN,   HCM-24-RFP, HCM-18-RFN, HCM-18-RFP, HKE-24-RFN, HKE-24-RFP,   HKE-18-RFN, HKE-18-RFP 8 6 10 7 9 12 13 16 17 3 5 15 1 11 2 4 16 www.desatech.com 115481-01A                                                                                                                                                                                                                                                                
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions  listed under Replacement Parts on page 12 of this manual.  PART NUMBER  HCA-24-RFN HCA-24-RFP HCA-18-RFN HCA-18-RFP KEY HCM-24-RFN HCM-24-RFP HCM-18-RFN HCM-18-RFP NO. HKE-24-RFN HKE-24-RFP HKE-18-RFN HKE-18-RFP DESCRIPTION QTY. 1 111814-01 111814-02 111814-01 111814-02 Gas Valve 1 2 115453-01 115453-01 115453-01 115453-01 Valve/Pilot Bracket 1 3 115457-01 115457-01 115458-01 115458
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        ACCESSORIES Purchase these appliances from your local dealer.  If they can not supply these accessories, call DESA  at 1-866-672-6040 for referral informatioin. You  can also write to the address listed on the back  page of this manual. EQUIPMENT SHUTOFF VALVE  GA5010 Equipment shutoff valve with 1/8" NPT tap. Fits  1/2" pipe. FIREPLACE HOOD Black - GA6050 Brass-GA6052 Antique Brss - GA6053 Helps deflect heat away from mantel or wall ab ove  fireplace. Fits opening 28" to 4" wide. DAMPER CLAMP - G
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        NOTES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ 
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our  standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VENT-FREE FIREBOX DESA warrants this product to be free from defects in materials and components for four (4) years from the date  of first purc