ملخص المحتوى في الصفحة رقم 1 
                    
                        SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY 
THIS MANUAL IS PRINTED ON RECYCLED PAPER 
EG 28 Direct Vent 
        By SHERWOOD INDUSTRIES 
OWNERS MANUAL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WHAT TO DO IF YOU SMELL GAS 
WARNING 
• Open windows 
If the information in this manual 
• Do not try to light any appliance. 
is not followed exactly, a fire or 
explosion may result causing 
• Do not touch any electrical switch; do not use any   
property damage, personal 
  phone in your bui
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                          SAFETY PRECAUTIONS  FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE,  CAREFULLY READ THE FOLLOWING INFORMATION:    • To prevent injuries do not allow anyone who is  GENERAL  unfamiliar with the operation to use the stove.    • Installation and repair should be done by a    qualified service person.  The appliance should  • Always keep the appliance area clear  be inspected before use and at least annually  and free of combustible materials, gasoline  by a qualified servic
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        TABLE OF CONTENTS    Safety Precautions 2  Code Approvals 3  Deciding where to locate your stove 4  Planning your installation 6  Installation of Log Sets and Embers 14  Operating Instructions 15  Maintenance and Technical 16  Trouble Shooting 17  Gas Line Connection 18  Electrical  19  Parts and Accessories 20  Fuel Conversion 21  Warranty 22  Parts List 23  Exploded Views 24-25  Installation Data Sheet 26  Mobile Home Information 3,13,19,21      CODE APPROVALS    • This Direct Vent appliance d
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        DECIDING WHERE TO LOCATE YOUR STOVE    DIMENSIONS:    Front Width: 22"/ 56 cm  Rear Width: 22"/ 56 cm  Height:       27-1/2"/ 70 cm*  Depth  19"/ 48 cm  (*not including vent coupling)    Shipping Weight:     210 lbs/95 kg            FIG. 1    CLEARANCES:    A. Side wall to stove  10"/ 25 cm  B. Rear wall to stove      4"/ 10 cm  C. Combustible to stove Top 22”/ 56 cm  D. Floor to stove    0"/ 0 cm  E. Corner clearance    2"/ 5 cm  F. Alcove depth   48"/ 122 cm    Maintain sufficient clearances  
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        VENT TERMINAL CLEARANCES                                A= Clearance above grade, verandah, porch, deck, or H= *Not to be installed above a meter/regulator assembly  balcony [*12 inches (30 cm) minimum] within 3 feet (90 cm) horizontally from the center-line of  B= Clearance to window or door that may be opened  the regulator  [*12 inches (30 cm) minimum] I= Clearance to service regulator vent outlet   C= Clearance to permanently closed window        [*6 feet (1.8m) minimum]  [minimum 12 inches 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS  STOVES. SECURITY VENTING SYSTEMS (SECURE VENT) Kits are available for vertical venting or horizontal venting.  It is  recommended that a bead of RTV High Temperature Silicone be applied to each outer vent joint and milpac to each inner joint  before installation.  This model has also been tested for horizontal venting installations when using SHERWOOD INDUSTRIES LTD. horizontal  venting 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        When planning your installation, it will be necessary to select the proper length of vent pipe for your particular requirements. It  is important to note when passing through a wall, the maximum allowable wall thickness is 10-inches (254mm), 1 ½  inches  clearance to combustibles must be maintained. Select the amount of vertical rise desired for “vertical-to-horizontal” type  installations. To determine the length of vent pipe required for vertical installations, measure the distance from the ap
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        STEP 7. Slide the decorative wall thimble up to the wall surface and attach with the screws provided. Apply decorative brass   or chrome trim if desired. FIG-14.     FIG. 11 FIG. 12                   FIG-13  FIG-14      NOTES:  (1) The four wood screws provided should be replaced with the appropriate fasteners for stucco, brick, concrete, or  other types of siding.  (2) For buildings with vinyl siding, a vinyl siding standoff (950), should be installed between the vent cap and the  exterior wall
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        VERTICAL INSTALLATION    STEP 1.  Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls,  roofs, enclosures, attic rafters , or other nearby combustible surfaces. Do not pack air spaces with insulation.    STEP 2.  Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance  flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this poi
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        NOTES:   (1) If an offset is necessary in the attic to avoid obstructions, it is important to support the vent pipe every 3 feet, to avoid  excessive stress on the elbows, and possible separation. Wall straps are available for this purpose. FIG-18    (2) When ever possible, use 45° degree elbows instead of 90° degree elbows. The 45° degree elbow offers less  restriction to the flow of flue gases and intake air.  NOTES:  (1) For multi story installations. A ceiling firestop (part 963) is required
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        CATHEDRAL CEILING INSTALLATION    STEP 1. Follow installation steps 1 and 2 under Vertical Termination.    STEP 2. Using the plumb bob, mark the centerline of the venting system on the ceiling and drill a small hole through the ceiling  and roof at this point. From the roof, locate the drill hole and mark the outline of the “Cathedral Ceiling Support Box”.    STEP 3. Remove shingles or other roof coverings as necessary to cut the rectangular hole for the “Support Box”. Cut the hole  1/8” larger 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Install 2 spring spacers around the flex pipe. Slide the horizontal section of pipe  over the flexible liner and install through the wall thimble, ensure that this  portion of pipe slides onto the vent termination cap. Slide the inside finished  collar over the horizontal section of pipe and secure to wall using the screws  provided. Slide the 90° elbow over the flex pipe. Stretch the flex liner to a  length long enough to ensure the flex liner can be easily connected to the flue  outlet of the 
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        VENTING INTO CLASS “A” CHIMNEYS    Simpson GS Dura  This model is also certified and tested to vent into  vent cap  CLASS “A” wood.    stove chimneys  Cap Adapter  Place the freestanding direct vent appliance in the    desired location.        Using Simpson Dura Vent conversion kit #s 931-932- Class “a Chimney  933, depend on the ID diameter of the CLASS “A”    chimney that this appliance is to be vented into.        Place a bead of high temperature silicone or mil pac at    each connection to e
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                           INSTALLATION OF LOGSET and EMBERS INSTALLATION OF LOGSET and EMBERS     INSTALLING THE GLOWING EMBERS INSTALLING THE GLOWING EMBERS     A bag of Rock Wool embers is provided for use on the burner. A bag of Rock Wool embers is provided for use on the burner.     CAUTION: Use only the type of ember material supplied with CAUTION: Use only the type of ember material supplied with this appliance. Due to the amount of ember material  this appliance. Due to the amount of ember material  there may b
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                         OPERATING INSTRUCTIONS    FOR YOUR SAFETY READ BEFORE OPERATING  WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION   MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.    A) This appliance is equipped with a pilot, which must be lit by • If you cannot reach your gas supplier, call the fire  hand by following these instructions exactly.  department.  B) BEFORE LIGHTING smell all around the appliance area  C) Use only your hand to  push in or turn the
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        MAINTENANCE AND TECHNICAL       To Replace:  Periodically check to ensure that your "Direct Vent"  • open door fully  system is clear.  • Lift door vertically so that hinge pins lift out of    hinge receivers.  Periodically check the pilot and burner.  Check to see  • Return the door assembly to dealer.  that all the burner ports are clean and clear.  Check  Door and glass assembly must be replaced as a  the pilot head for blockage.  Check to ensure the pilot  complete unit by your ENVIROGAS Dea
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        TROUBLE SHOOTING    Problem Possible Cause Solution  Spark will not light the pilot after Defective piezo igniter Check connections to igniter  repeated pressing of spark igniter -If igniter connections are good but  there is no spark-replace igniter   Broken spark electrode -Check for broken ceramic insulation  replace, electrode if broken   Miss-aligned spark electrode -If spark is not arcing from the  electrode to pilot- adjust by loosening  screws on pilot base.  Adjust and re- tighten  Pilo
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        GAS LINE CONNECTION     ORIFICE SIZES, PRESSURE AND BTU’S    NATURAL GAS PROPANE GAS   Main Orifice #42 dms #53 dms   Manifold pressure. 3.8” wc (0.95 kPa) 11” wc (2.74 kPa)   Min. Manifold pressure. 1.1” wc (0.27 kPa) 2.7” wc (0.67 kPa)   Supply Pressure. 7.0” wc (1.74 kPa) 12” wc (2.98 kPa)   Min. Supply pressure. 5” wc (1.25 kPa) 11.5” wc (2.86 kPa)   Max. BTUH Input. 26,500 Btu/h(7.87 kW) 26,500 Btu/h(7.87 kW)   Min. BTUH Input. 13,500 Btu/h(3.9 kW) 13,500 Btu/h(3.9 kW)   Output fan off 21,0
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        The ENVIROGAS EG 28.FS.DV. will operate with no external power supply. These models have a Millivolt gas  control which uses the pilot flame to generate enough electricity to operate the main burner.    The appliance when installed, must be electrically connected and grounded in accordance with local codes or in  the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY  STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 i
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        PARTS AND ACCESSORIES    Service Parts available from your local Envirogas Dealer    Burner Control Assembly Convection Blower  Natural Gas Pilot Assembly Light Bulb Holder  Propane Pilot Assembly Light Switch (momentary)  Door Bolt Fan Controller   Relief Door Gasket Log Set (with Embers)  Regulating Valve Thermocouple  Piezo Igniter Embers  Burner Switch Thermopile  Door Gasket  B-vent Spill switch 220°   Orifice Blank Convection Fan Sensor 120° (48°C)    Accessories    Gold trim Package   Low