ملخص المحتوى في الصفحة رقم 1 
                    
                        Peninsula woodBurning FirePlace
owner’s oPera Tion and insT alla Tion Manual
PFS
®
C US
ICC-ES #ESR-2542
Models (V)PN36-A
SAVE THIS BOOK
This book is valuable. In addition to instructing you 
on how to install and maintain your appliance, it also 
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep 
it with your other important papers.
This fireplace is approved for use as a wood burning 
fireplace or for use with a vented gas log approved
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                         WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury, property  damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualified  installer or local distributor. TaBle oF conTenTs Safety .................................................................. 2 Optional Gas Line Installation............................ 12 Product Dimensions ............................................ 3 Operation and Maintenance 
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        saFeTy  WARNING: Always leave  Continued glass doors fully opened or  fully closed when operating   WARNING: Use solid wood  fireplace. or processed solid fuel fire logs  only. When processed wood   WARNING: Children and  fuel fire logs are used, do not  adults should be alerted to the  poke or stir the logs while they  hazards of high surface tempera- are burning. Use only fire logs  tures and to stay away to avoid  that have been evaluated for  burns or clothing ignition. Young  the applicatio
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        1 43 /4" (109.8cm) Spacers on Sides of  FirePlace insT alla Tion Fireplace Provide  2" (5cm) Min. Clearance Required 1" (2.5cm)  From Pipe to  Clearance SELECTING LOCATION Combustibles To determine the safest and most efficient  location for the fireplace, you must take into  consideration the following guidelines: 1. The location must allow for proper clear- ances (see Figure 2). 2. Consider a location where the heat output  will not be affected by drafts, air condition- ing ducts, windows or d
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        FirePlace insT alla Tion Continued 2. If fireplace is to be installed directly on  carpeting, tile (other than ceramic) or any  combustible material other than wood  flooring, fireplace must be installed upon  1/2" MIN. a metal or wood panel extending full width  OVERLAP and depth of fireplace. 1/2" MIN. 3. Set fireplace directly in front of opening  and slide unit back until nailing flanges  touch side framing. Figure 7 - Ember Protectors 4. Check the level of fireplace and shim with  sheet met
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        2" X 4" Stud FirePlace insT alla Tion Drywall Continued Combustible Materials 33° 6" Nom. 12" Min. 9" Min. Fireplace Side View Front 3" Nom. Face 1 64" Min. 1 /2" Max. 65" Min. Fireplace Front View 16" 20" Min. Min. Figure 11 - Mantel Clearances to  Combustible Materials Figure 9 - Hearth Extensions Noncombustible  Seal Gaps with Top View of Fireplace Noncombustible Hearth  Drywall Mortar or Adhesive Extension 3 2 /4" Max. 8" Max. 4" (Approx.) 33° Nom. “Z” Type Ember Combustible 1 3 1 /2" Typ. 4
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        PIPE INSTALLATION VenTing insT alla Tion The pipe sections must be assembled inde- Continued pendently as the chimney is installed. When  Secure to Collars with  connecting chimney directly to the fireplace,  Duct Tape or Screws the inner flue pipe section must be installed first  with the lanced side up. The outer pipe section  Air Inlet can then be installed over the flue pipe section  Location with the hemmed end up. Press down on each  Must Allow pipe section until the lances securely engage
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        2" (5.1cm) VenTing insT alla Tion Minimum Continued Maximum length of pipe between supports   Angled Firestop is 6' of angle run. Maximum of two 6' angle  2" (5.1cm) run sections per chimney system (see Figure  Minimum 9, page 6). Ceiling  Support 12S-12DM Support  Straps 30 FT. Required 30 FT. Return  (9.14m) (9.14m) Elbow Figure 17 - Chimney Supports Return  Elbow 6' Max. (15.2 cm)  6' Max. (15.2 cm)  Figure 15 - Elbow Offset OFFSET RISE CHIMNEY LENGTH 6' Max. (15.2 cm)  A B 48" 36" 18" 12" 3 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Uncommon circumstances such as neigh- VenTing insT alla Tion boring hills, tall trees, or strong wind areas  Continued can cause down drafts in chimney system.  Existing  In such cases, going beyond the minimum  Ceiling  recommended height would be preferable to  Frame provide a better draw. Firestop  The fireplace height approved for any chim- Spacer ney run with this fireplace system is 40 feet  measured from bottom of fireplace to flue  Screws or  outlet-end of pipe (see Figure 22). Staples  
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Storm  VenTing insT alla Tion Overlap  Collar Continued Shingles Top  Flashing and Sides Only PENETRATING ROOF Cone To maintain a 2" clearance to pipe on a roof with  Nail Only  a pitch, a rectangular opening must be cut. Outer  Perimeter  1. Determine the center point through which  of Flashing pipe will penetrate roof. 2. Determine center point of roof. Pitch is the  distance the roof drops over a given span,  usually 12". A 6/12 pitch means that the  roof drops 6" for each 12" one measure  ho
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        FINISHING FIREPLACE VenTing insT alla Tion Combustible materials, such as wallboard,  Continued gypsum board, sheet rock, drywall, plywood,  RLT-12D Stainless  etc. may make direct contact with sides and  Inner Flue  Chase top around the fireplace face. It is important  Pipe Top that combustible materials do not overlap the  Screen face itself. Brick, glass, tile or other noncom- bustible materials may overlap the front face  provided they do not obstruct essential open- 1" Non- com- ings like l
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        oPTional as g ine l  CAUTION: All gas piping  insT alla Tion and connections must be tested  for leaks after the installation   WARNING: A qualified  is completed. After ensuring  service person must connect  that the gas valve is on, apply  fireplace to gas supply. Follow  soap and water solution to all  all local codes. connections and joints. Bubbles  NOTICE: Before you proceed, make sure your  forming show a leak. Correct  gas supply is turned off. all leaks at once. DO NOT USE  A gas line m
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        The following tips should be followed to as- oPTional as g ine l sure that both the fireplace and glass door  insT alla Tion retain their beauty and function properly.  Continued • Both the flue damper and glass doors must  be fully opened before starting fire. This  will provide sufficient combustion air and   WARNING: If the fireplace  maintain safe temperatures in firebox. has been used for wood burning,  • The glass must be allowed to warm slowly  the firebox and chimney must be  and evenly.
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        GRATE oPera Tion and  The grate is designed to provide you with the  MainTenance  maximum solid fuel capacity. Do not overload  uidelines g grate or obstruct required air space beneath  Continued it. Doing so may cause smoke spillage and  a fire hazard.  DAMPER MECHANISM The damper control lever is located inside the   WARNING: Risk of fire! Re- fire chamber (see Figure 32). Make sure lever  place grate with FMI PRODUCTS,  is cool before handling. Pull down to close and  push up to open. Damper 
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        rePlaceMenT and  accessory Par Ts ADjUSTABLE HOOD  Vent Plaster  Black - GA6050  Vent Hood Collar Brass - GA6053  Connector  Duct - 4" x 3' OUTSIDE AIR KIT - AK4 GRATE 11150 STORM COLLAR - SC2-1 FIRESTOP SPACER   FS-10 for Straight Pipe  EMBER  30FS-10 for 30° Angled  PROTECTORS  Run 20093 FLASHING  V6F-10DM 0 to 6/12  Pitch  V12F-10DM 6/12 to  DOUBLE WALL PIPE - 12-12DM,   18-12DM, 24-12DM, 36-12DM, 48-12DM 12/12 Pitch (Chimney pipe assembly includes outer  and inner pipes and comes with wire  
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        2701 S. Harbor Blvd. Santa Ana, CA 92704 115607-01 1-866-328-4537 Rev. D www.fmiproducts.com 09/09