ملخص المحتوى في الصفحة رقم 1 
                    
                        SAVE THESE INSTRUCTIONS.
Owner's Manual
Installation and Operation
Model:
P35i
Pellet/Biomass
Fireplace Insert
#1-70-774195
#1-70-774235
NOTICE
DO NOT DISCARD THIS MANUAL
 •  Important operating and
 •  Read, understand and  •  Leave this manual with 
    maintenance instructions    
     follow these instructions      party responsible for use 
    included.
     for safe installation and      and operation.
     operation.
 WARNING
WARNING
Please read this entire manual 
HOT SURFACES!
before i
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                                                 P35i Fireplace Insert Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you  have become part of a long standing family committed to meeting the heating needs of consumers with the most  distinctive, powerful and responsible home heating products available.  The P35i insert has brilliant features in an elegant package, giving you 0 to 35,000 BTU when you need it,  automatically. Aside from the regular, simple cleaning
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        P35i Fireplace Insert Safety Alert Key: •	 DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. •	 W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. •	 CAUTION! Indicates a hazardous situation which, if not avoided could result in minor or moderate injury. •	 NOTICE: Indicates practices which may cause damage to the appliance or to property. TABLE OF CONTENTS Section 1: Listing and Code Approv
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                                                 P35i Fireplace Insert Listing and Code Approvals 1  A.  Appliance Certification E.  BTU & Efficiency Specifications  Model:               P35i Insert Particulate Emissions Exempt from EPA per   Laboratory:       OMNI-Test Laboratories, Inc. Rating: 40 CFR, Method 28A  Report No.        135-S-25-6.2 0 or 6,000 - 35,000 / hr *BTU Input:  Type:      Solid Fuel Room Heater / Fireplace Heating Capacity: 1,500 sq. ft.       Insert. Hopper Capacity-   Standard(s):      ASTM E15
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        P35i Fireplace Insert Special Warnings and Notes 2  Carbon monoxide, referred to as CO, is a colorless, CO detectors are very sensitive and may sound an  odorless gas that is produced during combustion of solid alarm for fumes other than CO or CO from sources other  fuels. CO is toxic and can be fatal. than the stove such as a car or lawn mower exhaust. If the alarm sounds  Even though this stove is designed to be as safe  1. Increase house ventilation by opening windows or  as possible, it is r
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                                                 P35i Fireplace Insert Getting Started 3  A. Design, Installation & Location B. Fire Safety Considerations Maintain the designated clearances to combustibles.  1.  Appliance Location Insulation must not touch the chimney. You must  Consideration must be given to safety, convenience,  maintain the designated air space around the chim- traffic flow, and the fact that the appliance will need to  ney. This space around a chimney is necessary to  be vented to the outside. This
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        P35i Fireplace Insert C. Component  Locations Hopper Lid Latch Viewing  Glass Ash Pan Cover Door Latch Control Panel Return Air Slots Do Not allow finish materials to block  the air flow through the return air  slots. Combustion  Blower Exhaust  Sensing  Probe (ESP) Pellet Pro Feeder Feed Motor Distribution Blower Ash Pan Latch Frame Latch 7 Save These Instructions                                                                    3-90-775                                               Pellets or
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                                                 P35i Fireplace Insert D. Pre- Use Check List 1.  Place the appliance in a location near the  final installation and follow the procedures WARNING  below: Inspect appliance and components for  2. Open the appliance and remove all articles damage. Damaged parts may impair safe   packed inside. Inspect all items for shipping operation.  damage. Notify dealer of any missing or • Do NOT install damaged components.  damaged goods. • Do NOT install incomplete components. 3. All
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        P35i Fireplace Insert Dimensions & Clearances 4  A.  Appliance Dimensions A B 24” 60.96 cm Standard Surround Oversize Surround # 1-00-774221 # 1-00-774250 A:      40" (101.6 cm)           46" (116.8 cm) B:      31" (78.74 cm)   34" (86.36 cm) 22” 55.88 cm 14” 35.56 cm 2” 5.08 cm 8” 10” 20.32 cm 25.4 cm 9 Save These Instructions                                                                    3-90-775                                               Pellets or Corn/Pellet Mixture Only 19.5” 49.53 
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                                                 P35i Fireplace Insert D.  Minimum Opening for Masonry    B.  Clearances To Combustibles -        and Manufactured Fireplaces Masonry or Manufactured Fireplace ThE	ClEARANCEs	spECIfIED	 ARE	fOR	 yOUR	sAfETy!	 ThEsE	ClEARANCEs	mA y 	ONl y 	bE	REDUCED	by 	 mEANs	 AppROvED	by 	ThE	REGUlA T OR y 	 AUThORITy .   I  H Mantel Face Trim G B D Inches Millimeters Location A C Minimum Width 24              609 G Minimum Depth 14.5           368 H Minimum Height #1-70-774235    23½  
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        P35i Fireplace Insert F.  Factory-Built Fireplace Installation The factory built chimney must be listed per UL 127 (US)  and meet type HT requirements of UL 103 (US).  Factory  When installing the P35i Insert into a factory built  Built fireplace chimneys tested to UL 127-98 may be, at the  wood burning fireplace, several things need to be taken  fireplace manufacturers option, tested to the same criteria  into consideration. as UL 103HT requirements.  If the chimney is not listed as  The size o
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                                                 P35i Fireplace Insert Chimney connector shall not pass through an attic or roof  space, closet or similar concealed space, or a floor or ceiling. Vent Information 5  A.  Vent Termination Requirements = Vent Termination = Air Supply Inlet = Restricted Area WARNING: Venting terminals must not be recessed into  I. The clearance to service regulator vent outlet must be  1 a wall or siding. a minimum of 6 feet. NOTE: Only PL  or L vent pipe wall pass-throughs and  J. The clea
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        P35i Fireplace Insert B.  Avoiding Smoke and Odors Negative Pressure, Shut-down, and Power  Vent Configurations: To reduce probability of reverse drafting during  Failure: To reduce the probability of back-drafting or burn- shut-down conditions, Hearth & Home Technologies  back in the pellet burning appliance during power  strongly recommends: failure or shut-down conditions, the stove must  • Installing the pellet vent with a minimum vertical  be able to draft naturally without exhaust blower o
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                                                 P35i Fireplace Insert C.  Venting Requirements and  Use only the specified venting components. Use  of any other components will void the product  Restrictions warranty and may pose a hazard. A combustion blower is used to extract the combus- tion gases from the firebox. This causes a negative pres- Do Not Install A Flue Damper In The Exhaust  sure in the firebox and a positive pressure in the venting Venting System Of This Appliance. system. The longer the vent pipe and
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        P35i Fireplace Insert Be sure to design the venting so that it can be easily  D.  Existing Fireplace Installation: cleaned.  If using a short run of venting, whether flex or rigid,  Check with your local authority having jurisdiction to  through the damper and into the chimney flue; The  determine if this venting method is acceptable. Some  Damper must be removed or locked in the open posi- Provincial, State, or Local codes may require a full   tion and sealed with a plate constructed of steel o
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                                                 P35i Fireplace Insert The top of the chimney must also be sealed.  Otherwise, it can become a nesting area or a  E.  Existing Fireplace, Rear Vent: water trap. NOTE: When installed in a rear vent  configuration, the maximum BTU  may be reduced due to elevated ESP  temperatures associated with the  horizontal exhaust stream. If passing through combustible  material, the proper thimble from the  vent manufacturer must be used. F.  Optional Zero Clearance       Cabinet Inst
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        P35i Fireplace Insert Mobile Home 6  A.  Mobile Home Installation CAUTION Maintain structural integrity of mobile home: Outside Air Kit #1-00-774280 Must be used  • Floor, wall, ceiling and/or roof. for installation in a mobile home. Do NOT cut through: • Floor joist, wall studs, or ceiling trusses. 1. An outside air inlet must be provided for combus- • Any supporting material that would affect the  tion air, and must remain clear of leaves, debris,  structural integrity. ice, and/or snow. The o
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                                                 P35i Fireplace Insert Appliance Set-Up 7  The image at left shows the use of the chim- A.  Outside Air Attachment ney for outside air supply. Also shown is the  Chimney intake extension on the top of the  chimney. It is slotted to allow fresh air into  Outside Air Kit #1-00-774280 (sold separately) must  the flue. Be sure to use the proper flashing  be used for attaching outside air to the insert. This kit and vent cap to prevent rain from entering the  chimney flue. con
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        P35i Fireplace Insert B.  Installing the Surround The surround consists of three panels, the top and  two sides. Follow these steps for installation: 1. Remove the insert body from the mounting frame;  2.   Start your leveling bolts into the floor of the frame           and adjust to slightly raise the height.(see next                  section) This will allow some clearance to                assemble the surround.  3.   Prepare the side panels by removing three nuts          each. The left side
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                                                 P35i Fireplace Insert D.  Securing the Mounting Frame The mounting frame is the anchor for the appli- ance. If the frame is not secured properly, shifting  E.  Attaching the Venting will occur when sliding the insert in or out. There are four (4) holes located as shown, that are  threaded for 5/16 - 18 bolts. Thread the bolts down  through the holes to raise the frame corners as  needed, to level.  NOTE: When installed in a rear vent configuration, the maximum BTU  may b