ملخص المحتوى في الصفحة رقم 1 
                    
                        OPERATIONS MANUAL FOR THE MODEL DV23ZC 
DIRECT VENT ZERO CLEARANCE GAS FIREPLACE 
APPROVED FOR MOBILE HOME INSTALLATION 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
WARNING:  If the following information in this manual is not followed exactly, a fire or 
explosion may result causing property  damage, personal injury, or loss of life. 
 
-DO  NOT  STORE  OR USE GASOLINE OR OTHER  FLAMMABLE  VAPORS  AND  
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. 
 
-WHAT TO DO IF YOU SMELL GAS 
 * D
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        TABLE OF CONTENTS    Introduction .......................................................................................................................... 3  Specifications ....................................................................................................................... 3  Installation ........................................................................................................................... 5  Location and Clearance .......................................
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        2                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        INTRODUCTION    This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance  and vent system.  Please read and understand these instructions before beginning your installation.    The model DV23ZC is a sealed combustion, air circulating gas appliance designed for residential and  mobile home applications.  The appliance must be installed with Dura-Vent GS vent system that is  routed to outside atmosphere.  It is also listed for bedroom installations
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                            NOTE:  Installation and repair should be performed by a qualified service person.  The  appliance should be inspected annually by a qualified professional service person.  More  frequent inspections and cleanings may be required due to excessive lint from carpeting,  bedding material, pet hair, etc.  It is imperative that the control compartment, burners and  circulating air passage ways of the appliance be kept clean.    Provide adequate clearances around air openings and adequate accessibi
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        GENERAL INFORMATION  LOCATION AND CLEARANCE    Make sure your installation location  provides adequate combustion and ventilation air.    In selecting the location, the aesthetic and functional uses of the appliance are primary concerns.   However, vent system routing to the exterior and access to the fuel supply are also important.   Consideration should be given to traffic ways, furniture, draperies, etc., due to elevated surface  temperatures.   The location should also be free of electrical,
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        INSTALLATION                                                                                      Figure 1  6                                                                                                                                                                                                                                                                                                                                                                                                       
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        NOTE: *  SUPPLIED BY MANUFACTURER    INTERIOR HORIZONTAL MINIMUM INSTALLATION NOTE: * NOTE:  You may replace or  cover this piece of material with a  *  more decorative non-combustible   SUPPLIED BY MANUFACTURER  material when the unit is installed.  INTERIOR VERTICAL INSTALLATION WITH  A MAXIMUM 42' RISE. Figure 2  7                                                                                                                                                                                     
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        INSTALLATION  GENERAL INFORMATION    Remove the shipping carton.  Make sure the unit is not damaged.  Lift the top louver and remove  three (3)  nuts at the upper left, right, and center of the glass frame.  Also, open louver at bottom  and remove the three (3) nuts.  Set the  door aside and protect from inadvertent damage.  Retain   nuts  for reassembly.  Next, carefully remove the box of logs inside the appliance and set these  aside.    1.   Framing - Maintain dimensions for the appliance enc
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        V V INSTALLATION  EXTERIOR VENT LOCATIONS and RESTRICTIONS  INSIDE CORNER DETAIL TERMINATION BOX, LOCATION CHART G V A H   D E B C B L V FIXED FIXED CLOSED V CLOSED V F B M I B V J A B V A   OPENABLE K A V A = VENT TERMINAL = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A.  Clearance above grade, veranda, porch, deck, or H.  *Not to be installed above a meter regulator  balcony (*12 inches (30cm) minimum)  assembly within 3 feet (90 cm) horizontally from the   centerline of the regula
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        INSTALLATION    NOTE:      Direct-Vent (Balanced Flue) appliances are sensitive to vent configurations.  Although this  appliance may operate in some installations that fall outside this  vent requirement chart,  we cannot ensure its performance.    MINIMUM - MAXIMUM VENT REQUIREMENTS   42' 42'              18' 18'     VENTING MUST BE   TERMINATED WITHIN   SHADED AREA     12' 12'               6' 6'             0' 0'             * MINIMUM DISTANCE FROM   BEND OF 45° ELBOW TO FACE OF VENT CAP.   
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        INSTALLATION  VENT ASSEMBLY  There are two basic types of installations approved with your model DV23ZC appliance.    These are:  Horizontal termination (See Figure 5)    Vertical termination (See Figure 10)    When planning your installation, refer to Figure 3 to ensure the length of your vent falls into the  limits specified in Figure 3.  Also consult page 9, “Exterior Vent Locations and Restrictions”  regarding the placement of the vent terminal.    HORIZONTAL TERMINATION  1. Set the gas appl
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        INSTALLATION  HORIZONTAL TERMINATION (continued)    NOTE:   The horizontal run of vent must be level, or have a 1/4-inch rise for every 1 foot of run  toward the termination.  Never allow the vent to run downward.  This could cause high  temperatures and may present the possibility of a fire.     A 2" clearance (airspace) MUST be maintained on all vent pipe.    4. With the pipe attached to the appliance adapter, slide the appliance into its correct location,  and mark the wall for a 10" x 10" sq
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        INSTALLATION  HORIZONTAL TERMINATION (continued)    Note:      The four wood screws provided should be replaced with appropriate fasteners for stucco,  brick, concrete, or other types of siding.      Venting termination shall not be recessed into a wall or siding.  For structures with vinyl  siding,  a Vinyl Siding Standoff (Part 950) should be installed between the vent cap and the  exterior wall. (See Figure 7.)  Attach the Vinyl Siding Standoff to the Horizontal Vent  Termination.  The Vinyl 
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        INSTALLATION  VERTICAL TERMINATION  1. Set the gas appliance in the desired location.  Drop a plumb bob down from the ceiling to  the position of the appliance flue exit, and mark the location where the vent  will penetrate  the ceiling.  Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole  previously drilled in the ceiling, and mark the spot where the vent will penetrate the roof.   Determine if the ceiling joists, roof rafters or other framing will obstruct the v
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        INSTALLATION  VERTICAL TERMINATION (continued)    5. Slip the flashing over the Pipe Section(s) protruding through the roof.  Secure the base of the  Flashing to the roof with roofing nails.  Ensure the roofing materials overlap the top edge of  the Flashing as shown in Figure 12.  Verify that you have at least the minimum clearance to  combustibles at the roof line.                                Figure 12    6. Continue to add Pipe Sections until the height of the Vent Cap meets the minimum bu
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        INSTALLATION  VERTICAL TERMINATION (continued)    NOTES:    Use only 45 degree elbows.  Use of 90 degree elbows is not allowed in vertical terminations.   The 45 degree elbows offer less restriction to the flow of flue gases and intake air.      For multi-story vertical installations, a Ceiling Firestop, (Simpson-Dura-Vent, Part 963) is  required at the second floor, and any subsequent floors (Figure 14).  The opening should be  framed to 10"  x  10"  inside dimensions, in the same manner as sho
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        INSTALLATION    HIGH ALTITUDE    This unit is approved in Canada for altitude from 0 to 2,000 ft. (0 to 600m) (Can 2.17-M90) with the main  burner orifice supplied.  For installations above 2,000 feet, follow current CAN/CGA-B149.1 and B149.2.   In the USA refer to ANSI Z223.1 — latest edition, Appendix F, for resizing the orifice.    At altitudes greater than 2,000 feet it is necessary to match the air and fuel requirements by installing a  main burner orifice sized for the elevation that the a
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        L L I I P P INSTALLATION    GAS VALVE CONNECTION    The gas control valve is located behind the lower grill.  The control valve has a 3/8" NPT  threaded inlet port.    Secure all joints tightly using appropriate tools and sealing compound.  Leak-check the  installation with a soapy water solution or electronic leak detector.  DO NOT USE OPEN  FLAME FOR LEAK TEST.        SIT VALVE   SUPPLY LINE                1/2" SHUT-OFF     VALVE         Figure 15    GAS PRESSURE CHECKS    The gas valve is equ