                        www.regency-fi re.com
P121 / P121LC / P121RC / P131 
Owners & 
Zero Clearance Direct Vent Gas Fireplace
Installation Manual
STYLE                           MODEL    
See Thru P121-NG2 Natural Gas   P121-LP2 Propane  
Left Corner P121LC-NG2 Natural Gas   P121LC-LP2 Propane
Right Corner P121RC-NG2 Natural Gas  P121RC-LP2 Propane
Pier P131-NG2 Natural Gas   P131-LP2 Propane
WARNING:  
FOR YOUR SAFETY
If the information in these instructions are not followed exactly, a 
What to do if you smell gas:
fi
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        To the New Owner: Congratulations!  ® You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The P121 / P121LC / P121RC / P131  is a hand crafted appliance and has been designed to provide you with all  the warmth and charm of a  wood fi replace at the fl ick of a switch.  The model P121 / P121LC / P121RC / P131 has been approved by  Warnock Hersey for both safety and effi ciency.  As it also bears our own mark, it promises to provide you  with economy, comfort and security for many tro
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        TABLE OF CONTENTS SAFETY LABEL OPERATING INSTRUCTIONS Serial No. Decal ............................................................4 Operating Instructions .................................................34 Lighting Procedure ......................................................34 Shutdown Procedure ...................................................34 REQUIREMENTS  First Fire ......................................................................34 Aeration Adjustment .........................
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        SAFETY LABEL This is a copy of the label that accompanies  each P121-2/P121LC-2/P121RC-2/P131-2  Zero Clearance Direct Vent Gas Fireplace.  We have printed a copy of the contents here  for your review. The safety label is located  on the front inside base of the unit, visible  when the bottom louver is open. ® NOTE: Regency units are constantly being  improved. Check the label on the unit and  if there is a difference, the label on the unit  is the correct one. For the State of Massachusetts, in
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        REQUIREMENTS  MA Code - CO Detector 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements:  (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for  residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than  seven (7) feet above finished grade in the area of the venting, includ
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        INSTALLATION IMPORTANT MESSAGE  GENERAL SAFETY INSTALLATION  INFORMATION CHECKLIST SAVE THESE  INSTRUCTIONS 1) The appliance installation must conform  with local codes or, in the absence of Note: These units are The Panorama P121/P121LC/P121RC/P131- local codes, with the current Canadian or  non-load bearing.  NG1 or P121/P121LC/P121RC/P131-LP1 Direct  National Gas Codes, CAN1-B149 or ANSI   Vent Fireplace must be installed in accordance    Z223.1 Installation Codes. with these instructions. Ca
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        INSTALLATION SPECIFICATIONS P121-2 See Thru Note: These units are  non-load bearing.  P131-2 Pier ® Regency P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace 7                                                                                                                                                                                                                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        INSTALLATION P121LC-2 Left Corner Unit Note: These units are  non-load bearing.  P121RC-2 Right Corner Unit ® 8 Regency P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace                                                                                                                                                                                                                                                                                                                    
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        INSTALLATION LOCATING YOUR  A) P121-2 See Thru GAS FIREPLACE 1) When selecting a location for your fi replace,  ensure that the clearances are met as  outlined in the "Clearances" section. 2) Provide adequate clearances for servicing. 3) The appliance must be installed on a fl at,  solid, continuous surface (e.g. wood, metal,  concrete). This may be the fl oor, or raised up  on a platform to enhance its visual impact.  If the appliance is going to be installed  on carpeting, combustible linoleum ti
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated (refer to diagrams in the "Locating Your Fireplace" section): Clearance to Combustibles from:   Back 0" (0mm)    Side 0" (0mm)   Floor 0" (0mm)   CAUTION REQUIREMENTS: The top, back and sides of the fi replace are defi ned by standoffs. WARNING:  The metal ends of the standoffs may NOT be recessed into combustible construction. Fire hazard is an extreme risk  if these clearances (air space)  Determine
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        INSTALLATION FRAMING AND FINISHING 1) For ease of installation, frame your fi replace after it is positioned and  Framing Dimensions the vent system is installed. Remember to install the top standoffs.  See the "Unit Assembly Prior to Installation" section.  Use 2x4's and       P121-2 (See Thru)     P131-2 (Pier) P121LC-2 / P121RC-2 frame to local building codes.    (Corner Unit) A 25"(635mm)    25"(635mm) 26-13/16"  CAUTION: Verify your fi replace dimensions, framing methods and   minus two times
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        INSTALLATION Facing & Finishing Requirements This fi replace is supplied with a 3" metal extension trim above the fi replace. The extension trim may be replaced if the framing is faced with a non- combustible material placed fl ush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.) UNIT ASSEMBLY  VENTING  PRIOR TO INTRODUCTION INSTALLATION The  P121-2/P121LC-2/P121RC-2/P131-2  uses   the  "balanced  fl ue"  technology Co -Axial system.  The 4 Top
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS ® Regency P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace 13 Minimum  Vent  Height Roof  Pitch B-Vent Only: If  vent  is  less  than  10  ft. Feet Meters (3m)    from  wall  -  locate  rain  cap  not  less flat  to  7/12 2 0.61 than  2  ft.  (600mm)  above  wall. over  7/12  to  8/12 2 0.61 over  8/12  to  9/12 2 0.61 over  9/12  to  10/12 2.5 0.76 over  10/12  to  11/12 3.25 0.99 G over  11/12  to  12/12 4 1.22 over  12/1
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. ® Description     Simpson Dura-Vent     Selkirk            Amerivent               Security ® TM ®            Direct VentGS Direct-Temp          Direct Vent          Secure Vent 6" Pipe Length, Galvanized   908             4DT-6  N/A  SV4L6 6" Pipe Length, Black    908B             4DT-6B  N/A SV4LB6 7" Pipe Length, Galvanized   N/A             N/A   4D7 #N/A 7" Pipe Length, Black   
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        INSTALLATION VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS ® Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P121-2/P121LC-2/P121RC-2/P131-2 Direct Vent Gas Fireplace, have been tested and listed as a  direct vent heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations  diagram in the "Exterior Vent Termination Locations" section. ® Regency Direct Vent (Flex)
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations The minimum components required for a basic horizontal  termination are:  1 Simpson Duravent Adaptor  1 Horizontal Termination Cap o  1 45 Elbow   1 Rigid Pipe Adaptor Vertical  1 Wall Thimble Terminal  1 Length of pipe to suit wall thickness Storm Collar   (see chart)  Part # 953 Vinyl Siding Wall thickness  is measured from the back standoffs to the inside Standoff (Optional) (Part #950) mounting surface of termination
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        INSTALLATION RIGID PIPE VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS REGENCY DIRECT VENT SYSTEM (FLEX)  (Propane & Natural Gas) o o o The diagram below shows examples of horizontal termination arrangements using one, two, or three 90 elbows (two  45 elbows equal one 90  elbow). Note:  All Rigid Pipe Systems o 1) A maximum of three 90 elbows are permitted.  4" inner diameter 2) Minimum distance between elbows is 1 ft. (305mm). 6-5/8" outer diameter •  Maintain clearances to combustibles as listed
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        INSTALLATION  o o Horizontal Venting with Three (3) 90 Elbows Horizontal Venting with Two (2) 90 Elbows  Option  V           H        H + H1 + H2  Option  V   H + H1       A) 2' (610mm) Min. 1' (305mm) Max. 3'(914mm) Max.      A) 1' (305mm) Minimum 2' (610mm) Maximum       B) 3' (914mm) Min. 3' (914mm) Max. 6' (1.86m) Max.      B) 2' (610mm) Minimum 5' (1.5m) Maximum       C) 4' (1.22mm) Min. 5' (1.5m) Max. 9' (2.7m) Max.      C) 3' (914mm) Minimum 8' (2.4m) Maximum       D) 5' (1.5m) Min. 7' (2
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        INSTALLATION RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS  (Propane & Natural Gas) • Vent must be supported at offsets • Maintain clearances to combustibles as listed in the "Clearances" section. • Firestops are required at each fl oor level and whenever passing through a wall. • Must use optional rigid pipe adaptor when using rigid pipe vent systems (Part# 510-994). The P121-2/P121LC-2/P121RC-2/P131-2 is approved for a maximum 35 ft. (10.7m) straight vertical, with rigid pipe vent sys
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        INSTALLATION o o Vertical Venting with Two (2) 90 Elbows Vertical Venting with Two (2) 90 Elbows  Option  V           H + H1  Option  V + V1   H       A) 1' (305mm) Minimum 2' (610mm) Maximum       A) 1' (305mm) Minimum 4' (1.22m) Maximum       B) 2' (610mm) Minimum 4' (1.22m) Maximum       B) 2' (610mm) Minimum 6' (1.86m) Maximum       C) 3' (914mm) Minimum 6' (1.86m) Maximum       C) 3' (914mm) Minimum 9' (2.7m) Maximum       D) 4' (1.22m) Minimum 8' (2.4m) Maximum       D) 4' (1.22m) Minimum