INSTALLER/CONSUMER 
SAFETY INFORMATION
PLEASE READ THIS MANUAL 
BEFORE INSTALLING AND 
Chateau™ 
USING APPLIANCE
WARNING! 
Direct Vent Gas 
IF THE INFORMATION IN THIS 
MANUAL IS NOT FOLLOWED 
Fireplace
EXACTLY, A FIRE OR EXPLOSION 
MAY RESULT CAUSING 
Model:  DVT38, DVT44
PROPERTY DAMAGE, PERSONAL 
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must 
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Chateau™ Table of Contents Please read the installation & operating instructions before using this appliance. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT:  Read all instructions and warnings carefully before starting installation.   Failure to follow these instructions may result in a possible fire hazard and will void the warranty.   Installation &   Important Curing/Burning Instructions .........................................................3   Oper
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Chateau™ Installation & Operating Instructions This gas fireplace must be installed by a qualified installer,  12. This fireplace requires adequate ventilation and  preferably NFI or WETT (Canada) certified, in accordance  combustion air to operate properly.   with local building codes and with current CSA-B149.1  13. This fireplace must not be connected to a chimney flue  Installation codes for Gas Burning Appliances and  serving a separate solid fuel burning fireplace. Equipment. For USA Installation
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Chateau™ Fireplace Dimensions - DVT38 11 ���" Rough (298mm) 17" (432mm) Opening Depth 8���" Dia. 54" (1372 mm) (213 mm) 3" (76 mm) 11" Dia. (279 mm) 25���" (648 mm) 28���" (724 mm) Rough Opening Width ����� " 3/4" (19 mm) (1114 mm) Rough Opening Height 1���" No combustible  49���" (41 mm) (1257 mm) material in this area  33���" (848 mm) 12����” �����" (876 mm) (319 mm) 29���" (746 mm) 17 ����” 1/2" (13 mm) (440 mm) 7�����” 37���" (962 mm) 2���" 7����” (60 mm) (195 mm) (186 mm) No drywall in this
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Chateau™ Combustible  Locating Your Fireplace Framing and  Fin- ish Wall Above  V Standoffs May use combus- W tible facing mate- E A B rial in this area Y X Standoff X Y C Z D Y B A B C D E F Noncombustible Fin- ish Material LU584-1 (Such as Dura Rock) Fireplace Front Top of Sheet  Fig. 3  Locate gas fireplace. LU584-1 CFM146c Metal Locating unit A) Flat on wall  B) Cross corner C)  **Island 2/4/99   djt Mantel Chart D) *Room divider E) *Flat on wall corner F)  Chase installation   Mantel Shelf  
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Chateau™ Hearth A hearth is not mandatory but is recommended for   aesthetic purposes. We recommend a noncombustible  hearth which projects out 12” (305 mm) or more from  the front of the fireplace. The hearth cannot exceed 1 ¹⁄₂”  (38mm) in height from bottom of fireplace for ease of  door accessibility. (Fig. 5) Cold climate installation recommendation:   When installing this unit against a non- insulated exterior wall or chase, it is  mandatory the outer walls be insulated to  conform to applic
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Chateau™ Gas Line Installation Gas Specifications     Max. Min. When purging gas line the front glass must      Gas  Input  Input be removed.  Model Fuel Control BTU/hr BTU/hr  DVT38IN Natural Gas American Flame 46,000 32,000 A gas shut off valve must be installed on   DVT38IP Propane AF-4034 46,000 36,000 the gas pipe line going into the appliance   DVT44IN Natural Gas with 60,000 37,000 within easy access. Refer to local codes.  DVT44IP Propane 7.5V DC Hi/Lo 60,000 45,000 The gas pipeline can b
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Chateau™ 6. Remove pilot assembly from burner assembly by  Electrical Junction Box removing two (2) screws. The fireplace, when installed, must be elec- 7. Carefully slide the burner assembly to the left out of  trically connected and grounded in accord- the way, taking care not to bend or break the pilot  ance with local codes or, in the absence  tubes or wiring. of local codes, with the current CSA C22.1  8. Remove 13 screws around the perimeter holding  Canadian Electrical Code or the national
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        PO WER IPI Chateau™ NOTE: If you need to test the inlet pressure and/or  Learn  Button manifold pressure, there are two (2) test ports available  along the right side front edge between the firebox side  and outer casing. The upper test port is inlet pressure.  Junction Box The lower test port is manifold pressure. CAUTION: Turn off the gas supply before  S I Continous Pilot Off/On Remote/Off ADJ. removing test port plug. 23. Using a 7/16” nut driver, remove the threaded plug  from the test port.
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Chateau™ White or Green To Pilot Ignitor Green or White White or Orange Orange or White To Pilot  Flame Sensor DC Motor Pilot Main Module AF-4000 Learn  Main Optional Remote Button Battery Back-Up Pack Power Orange Black Remote/Off  Red Module Red Brown Switch Black Continuous Pilot ON/OFF Switch Pulse/Continuous Extension Button Wire Harness Black Gnd Brown (SWI) (Leave  Brown Disconnected) (SWI) Red Black AC Adaptor FP1795 Optional Extension Harness Fig. 11  DVT38/44 wiring diagram. FP1795 Cha
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        V V �������� Chateau™ General Venting Information - Termination Location INSIDE CORNER DETAIL G V N H N A D E B C B ����� ����� L V B V ������ ������ V ����� �������� G ������ F V V B M V G B X B J I X V K V A A VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED V CFM145a 1 2   Canadian Installations US Installations  A = Clearance above grade, veranda, porch,  12” (30 cm)  12” (30 cm) CFM145a DV Termin Location   deck, or balcony 5/01/01 Rev. 12/05/01   B = Clearance to wi
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Chateau™ Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors.  Inside Corner Alcove Applications* Outside Corner D C C F = Combustible  G =   6" (152 mm) Combustible   V G   6" (152 mm) Noncombustible  V E   2" (51 mm) Noncombustible  O V F   2" (51 mm) Balcony - Balcony -  with no side wall with perpendicular side wall E = Min. 6” (152 mm) for  non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.4 m) Min. M  No.  M  of Caps  
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Chateau™ General Information  Pipe Section Assembling Vent Pipes Pipe  Rim SK8 Venting Pipes  Hem Canadian Installations: Lance The venting system must be installed in accordance  Pipe  with the current CSA-B149 .1 installation code. Rim USA Installations: The venting system must conform with local codes and/ or the current National Fuel Gas code  ANSI Z223.1/ NFPA 54. Only venting components manufactured by CFM Cor- poration can be used in Direct Vent systems.  NOTE: The joints of the inner pip
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Chateau™ Minimum clearance between vent pipes  �� �� and combustible materials is 3 ¹⁄₂” (89 mm)  �� on top, 2 ¹⁄₂” (64 mm) on both sides and 1 ¹⁄₂”  �� (38 mm) on the bottom. �� �� When the vent termination exits through foundations  �� less than 20” (508 mm) below siding outcrop, the vent  �� pipe must be flush with the siding. �� �� It is always best to locate the fireplace in such a way  �� that minimizes the number of offsets and horizontal  �� vent length of vent pipe from the flue collar of 
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Chateau™ • The maximum number of 45° elbows permitted per  Sidewall Installation side wall installation is two (2). These elbows can be  installed in either the vertical or horizontal run. (Fig.  STEP 1 18) Locate vent opening on the wall. It may be necessary  • For each 45° elbow installed in the horizontal run,  to first position the fireplace and measure to obtain hole  the length of the horizontal run MUST be reduced by  location. Depending on whether the wall is combustible  18” (45 cm). This
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Chateau™ STEP 3 X Slide the zero clearance sleeve through the wall and  install the firestop on the inside surface of the wall.  Secure with four (4) #8 sheet metal screws. STEP 4 Place fireplace into position. (Fig. 22) Measure the ver- tical height (X) required from the base of the flue collars  to the center of the wall opening. NOTE: If using the  SK8DVSK Kit, the vertical section of pipe is telescopic  and could provide adjustment from 24” up to 40” (610  mm to 1016 mm). FP1241a Fig. 23  Horiz
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Chateau™ 12' DVT44 - Natural or LP (3.7m) Use 6 ���" or Greater DVT38 - Natural or LP 'X' Use 5 ���" Fresh Air Restrictor Plate  X Setting  30’ to 40’ #1  20’ to 29’ #2  12’ to 19’ #3 FP1409 FP1243a Fig. 26  Restrictor plate use in straight up installation. Fig. 25   Secure termination to wall. For vertical venting configurations that include a  FP1409 restrictor plate minimum vertical rise of 12’ (3.7 m) and a maximum  Vertical Through-the-Roof  straight up installation horizontal offset of 10’ 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Chateau™ Max. 8' (2.4m) 4 Max. 20' (6 m) Max. Height 40' (12 m) Min. Height 1 + 2 + 3 + 4 = 270° 20' (6 m) 3 2 1 Pipe Straps Every 3’  (914mm) Minimum 2’ (610mm)  Before Any Elbow FP1244a   Fig. 28  Support straps for horizontal runs. FP1245a • Up to two (2) 30° or 45° elbows may be used within  FP1245a through the roof Fig. 29  Typical offset application. the horizontal run. For each 30° or 45° elbow used  90 & 45 degree  on the horizontal level the maximum horizontal  FP1244a through the roof 
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Chateau™ Support Structure Attic Installation Elbow Strap Nails (4) Firestop Spacer Elbow Strap (must be tight) Joist Ceiling Hole  Framing Angled Strap Ceiling Installation Angled Firestop Chimney Support Strap  (must be tight) Joist FP270/271 FP270/271 CR Series Fig. 32  Attach straps to a structural framing member. 2/19/99   djt Firestop Spacer Nails (4) Min. FP593 2' (610mm) Fig. 30  Installing firestop spacer. FP593 SR/C Attic  Insulation  11/20/97 Shield Nails (4 Re- quired) CFM190 Attic Jo
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Chateau™ Chimney Components Component Description Model Number  Horizontal Starter Kit Contains 24”-40” telescopic pipe* for minimum vertical     SK8DVSK      rise from collar pipe, 90° elbow, horizontal          through-wall starter pipe, zero clearance sleeve,          metal adhesive tape, stove cement tube, sidewall          termination and firestop.   SK8 Chimney Sections Pipe used to build 8” (SK8) flue systems.  SK81 (1’ Long)     SK818 (1Z\x’ Long)       SK83 (3’ Long)       SK84 (4’ Long)