Decorative Gas Appliance
Model: NV360
 NV580    
INSTALLER/CONSUMER 
SAFETY INFORMATION
PLEASE READTHIS MANUAL 
BEFORE INSTALLING AND USING 
APPLIANCE.
WARNING: IF THE INFORMATION IN 
THIS MANUAL IS NOT FOLLOWED EX-
ACTLY, A FIRE OR EXPLOSION MAY 
RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS 
OF LIFE.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service 
agency, or the gas supplier. 
What to do if you smell gas:
• Do not try to 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        NV360/580 Series  Table of Contents Thank you and Congratulations on your purchase of a Majestic Fireplaces fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these  instructions may result in a possible fire hazard and will void the warranty. Installation & Operating Instructions   General Information .....................................................
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        NV360/580 Series Installation & Operating Instructions This gas appliance should be installed by a qualified  wood, this appliance must be installed on a metal or  installer in accordance with local building codes and with  wood panel extending the full width and depth of the  current CSA-B149.1 Installation codes for Gas Burning  appliance. Appliances and Equipment. If the unit is being installed  12. This appliance requires adequate ventilation and  in a mobile home, the installation should com
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        NV360/580 Series  Fireplace Dimensions Rough J Opening Depth � R � � � � Recessed C K L Nailing Flange T - Rough Opening Width � � Rough G Opening � Height F Outside Air Gas Line S Access B D C L P E M O Electrical Access N Q A G Fig. 1   Fireplace specifications and framing dimensions. 3565a  Ref. NV360 NV580 NV360 Specs   A 41" (1046 mm) 47" (1194 mm) 12/6/00   djt  B 37 ¹⁄₂" (953 mm) 41 ¹⁄₄" (1048 mm)  C 36" (914 mm) 42" (1067 mm)  D 24 ¹⁄₂" (622 mm) 28 ¹⁄₂" (724 mm)  E 7" (179 mm) 7"  (179 mm
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        NV360/580 Series Clearance to Combustibles Appliances  Top .......................................................... 0” (0 mm)  Bottom ..................................................... 0” (0 mm)  Side ......................................................... 0” (0 mm)  Back ........................................................ 0” (0 mm) J  Perpendicular Sidewall ........................... 0” (0 mm) I H Black   Top of unit to ceiling .......................... 36” (914 mm) G Surround  F 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        NV360/580 Series  Framing and Finishing Air Shutter Setting  Model Front Rear  Check appliance to make sure it is levelled   NV360RN closed closed and properly positioned.  NV360RP open open  NV580RN closed closed 1. Choose unit location.  NV580RP open open 2. Nailing flanges are supplied with the fireplace (found  on the fireplace hearth). To level the box and secure  Gas Inlet & Manifold Pressures it firmly in place, remove the nailing flanges from  Natural LP the hearth and install at the sides of
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        NV360/580 Series Alternate Switch Location 1/2" Gas Supply The remote switch can be installed on either side of  1/2" NPT x 3/8" Flare  Shut-off Valve the access door. Mount the switch to the switch bracket  3/8" Flex Line provided. Screw the bracket on either side of the frame,  (from valve) line up the screws with the prepunched holes. (Fig. 6) FP297a Fig. 4  Typical gas supply installation. The fireplace valve must not be subjected  to any test pressures exceeding 1/2 psi.  Isolate or disconne
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        FRONT OF UNIT NV360/580 Series  INSIDE  Install the Venting System,  Electrical Box Flashing and Termination NOTE: The NV360 uses a 6" B-vent system. The  NV580 uses an 8" B-vent system (refer to Accessories,  Page 23 for adapter). Refer venting installation instructions provided by the  B-Vent manufacturer.   Refer to Page 4, Figure 1 to locate chimney centerline  OUTSIDE dimension from a combustible back wall. • Minimum vertical chimney height — 12 feet (3.65 m).  (measured from the bottom of 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        NV360/580 Series Venting Runs  Horizontal Run (in feet) 1    2    3    4    5    6     7 8    9   10  11  12 40 38 A 36 B 34 32 30 28 26 24 22 20 18 16 14 12 = Acceptable venting configuration = Unacceptable venting configuration A: Vertical installations up to 40 feet (12m) in       height. Up to an 8 ft. horizontal vent run can be      installed within the vent system using a       maximum of two (2) 90-degree elbows or four (4)       45-degree elbows. B: Vertical installations up to 40 feet (
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        NV360/580 Series  Operating Instructions Glass Information Glass Frame Only glass approved by CFM Corporation  Fireplace  Front should be used on this fireplace. • The use of any non-approved replacement glass will  Clamps void all product warranties. Glass  • Care must be taken to avoid breakage of the glass. Panel • Do not operate appliance with glass front  Glass  Panel removed, cracked or broken. • Replacement glass (complete with gasket) is  Pull Clamp  available through your Majestic Firepl
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        NV360/580 Series 1. Remove window frame assembly. (Refer to  Page 10) 2. Remove logs from packaging. As with all plastics - these are not  Log Top  Log Top  toys and should be kept away form Left Right children and infants. 3. Place rear log on rear bracket (ensure log is  Log Rear seated properly, leveled and centered to the  unit), so it will not move form side to side and  Log  is firmly positioned on the bracket. Be sure log  Front  is as far back as possible on bracket. Right 4. Place front 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        HI H NV360/580 Series  Inspecting the Venting System Turn counterclockwise Turn clockwise This appliance venting system was designed and con- to increase to decrease structed to develop a positive flow adequate to remove  flame height flame height flue gases to the outside atmosphere. HV102 Any foreign object in the venting system, except those  designed specifically for the venting system, may cause  Fig. 13  Flame adjustment knob for Honeywell valve. spillage of flue gases.  Turn To inspect the ve
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        NV360/580 Series is not, turn the unit off and check for causes creating CAUTION: The firebox, Vent Safety Switch sensor  the lack of adequate draft. and surrounding panels become very hot during  normal operation. Allow time for the components to  Do not operate the unit until lack of ad- cool before carrying out any service or inspection. equate draft has been determined and  rectified.  If the sensor is activated and shuts off the burner as- sembly, the following procedure should be followed:  
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                          H   I           P                       I       H               O WHITE L 1  5 3  4 NV360/580 Series  WHITE PILOT HONEYWELL S8600 B IGNITION MODULE GND 24V MV     MVPV     PV SPARK 24V SENSE (BURNER) GND WHITE WHITE BLACK BLACK BLACK WHITE NOVA SIT 822 VALVE BLACK 24 VAC HOT 120 VAC RTN BLACK BLACK WHITE WHITE BLACK WHITE "ON/OFF" 120 VAC HOT 24 VAC RTN SWITCH 40VA  GREEN TRANSFORMER FP670 Fig. 19  Vent Safety Switch wiring, EN/EP units. Thermopile FP670 NOVA SIT 822 VALVE WIRING DGRM.  (w/ Ho
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        O 3 2 ON 1 T O NV360/580 Series Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion  may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- • If you cannot reach your gas supplier, call the  ally. When lighting the pilot follow these instruc- Fire Department tions exactly. C. Use only your hand to push in or turn the gas  B. BEFORE LIGH
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        NV360/580 Series  Troubleshooting Honeywell VS8420 Standing Pilot Remove Glass Panel Before Servicing. ST ART CHECK • Supply line hooked up Gas Supply ON NO • Shutoff valve open YES • Lockout has engaged. Wait     60 seconds and try again. • For spark at electrode while Pilot Lights with  NO    depressing Piezo - 1/8" gap to Piezo Ignitor    pilot hood needed. • All wiring connections • Replace Piezo ignitor YES • For air in lines • Thermopile needs a minimum    325mV. Adjust pilot flame height.
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        NV360/580 Series Troubleshooting  SIT NOVA 820 MILLIVOLT VALVE NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "ON" position. WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. POSSIBLE CAUSES SYMPTOM CORRECTIVE ACTION A. Defective or misaligned elec- 1. Spark ignitor will not light. Using a match, light pilot. If pilot lights, turn off pilot and  trode at pilot. push the red button again. If pilot will not light - check gap  at e
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        O O L L I I P P F F F F O O L L I I NV360/580 Series  2. Insure the rubber gasket (D) is properly positioned  Fuel Conversion Instructions and install the new HI/LO pressure regulator assem- To convert the DV360/580 units for use with a different bly to the valve using the new screws (E) supplied  gas follow these instructions. Before proceeding, turn with the kit. Tighten the screws securely. (Ref. torque  control knob on valve to “OFF” and turn gas supply = 25 in/lb) (Fig. 23) OFF. Turn OFF an
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        NV360/580 Series 4. Remove both air shutters from burner pan by remov- Pilot  ing shutter retaining screw then air shutter. (Fig. 26) Hood 5. Install air shutters supplied in kit on burner pan.  Replace shutter retaining screw. For conversion to  Natural Gas adjust new air shutters so slots are cov- ered. For conversion to Propane Gas, adjust new air  Pilot  shutters so slots are open. NOTE: NV360 air shutter  Bracket has only one hole, closed. Secure shutter retaining  screws. (Fig. 27) CO105a 
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        NV360/580 Series  Maintenance Burner and Burner Compartment It is important to keep the burner and the burner com- To obtain proper operation, it is imperative that the pilot  partment clean. At least once per year the logs and lava  and burner’s flame characteristics are steady, not lifting  rock/ember material should be removed and the burner  or floating. compartment vacuumed and wiped out. Remove and  Typically, the top 3/8” or 1/2” of the thermopile should  replace the logs as per the instruc