                        Installation and Operation Instructions 
for 
GAS-FIRED
Vented Gas Log Sets
 
Model OD24SHKN/P
DECORATIVE GAS APPLIANCE FOR INSTALLATION IN ODSR36/42A FIREPLACES
W A R N I N G 
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, 
CAUSING PROPERTY DAMAGE, INJURY, OR LOSS OF LIFE. 
FOR YOUR SAFETY:
DO NOT STORE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS NEAR THIS OR 
ANY OTHER APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
• SHUT OFF ALL GAS TO THE APPLIANCE.
• D
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam- age.  Read these directions thoroughly before installation.  For assistance or additional information,  consult your gas log dealer, qualified installer, service agency or  gas supplier. WARNING If not installed, operated, and maintained in accordance with the manufacturer’s instructions, this prod- uct could expose you to substances in fuel or fuel combustion which are known to the Sta
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        General Information • WARNING: If the fireplace contains glass doors,  In order to assure a safe and effective instal- they must remain open at all times during the opera- lation, only a qualified service person who is  tion of the logset, allowing combustion air to circulate. familiar with the building codes and installation  • In order to avoid any possible gas leaks, apply pipe  techniques appropriate to your area may install  joint compound to all non-flared threaded connections  and service th
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                         Pre-Installation Checklist Yes No Is the gas type you are using the same as the gas type listed on the rating plate for this  appliance? Does the firebox meet the minimum size dimensions below? Is the gas supply inlet pressure correct? Refer to Table below. Is your fireplace plumbed with gas on the right side (facing) of the fireplace?  If not,  refer to page 5. Is the gas supply line sized properly (Minimum 1/2” Iron pipe)? Do you have a solid fuel (wood burning) fireplace with a vented flue? Do yo
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        4. Attach one end of the Flexible Gas Connector to  the brass Burner Inlet Fitting which has been factory  installed into the burner. 5. Attach the other end of the Gas Connector to the  flared side of the Gas Supply Fitting.  Remember to use pipe thread sealant or teflon tape  only on the straight pipe threads.  Do not use on  any flared ends. CFM149 Fig. 2  Natural gas connection. Gas Plumbed on Left Hand Side of Fireplace CFM149 R-CFL Gas Supply Connection NOTE: Your gas log set is assembled at 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Leak Test Procedures After connecting the gas supply, test for leaks. Use a 50/50 solution of liquid soap and water to test for  leaks at gas fitting and joints. Apply water/soap solution with brush only - do not over apply. NEVER test  with an open flame.  WARNING: DO NOT USE AN OPEN FLAME TO TEST FOR LEAKS! NOTE: Always perform a leak test any time the appliance has been moved or disconnected from the  gas supply line. Damper Stop Installation                                                     
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Grate Placement Grate Assembly Place grate assembly over top of burner so the  front middle leg of the grate is 1 ¹⁄₂” back from  the front edge of the main burner pan assembly.  (Fig. 7) Lava  Rock Pan  Assembly FP1488 Fig. 8  Lava rock placement. 1 ¹⁄₂" FP1487 Fig. 7  Grate placement. FP1488 OD24 lava rock Add Pan Material 5/10/04 djt 1. With burner pan and grate in place, open the  Glowing Embers bag of lava rock and spread it evenly across the  FP1489 pan assembly to the top of the pan assem
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Log Placement Optional Glass Door Set The optional glass door set is for weather exposure  1. Place the larger bottom logs (longer log in back,  protection of gas logs for the ODSRA Series fireplaces. shorter (2) logs in front) onto the grate, leaving as  much space between them as possible. (Fig. 12) CAUTION: The glass doors must be fully open  when operating the gas log set.  Unit Model  ODSR36A 36GDKSSSR Back Log  ODSR42A 42GDKSSSR Front (2)  Shorter Logs Grate Retainer FP1149 Fig. 12  OD24SHK
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        For Your Safety Read Before Lighting WARNING: If you do not follow these directions exactly, a fire or explosion may result caus- ing property damage, personal injury, or loss of life. What To Do If You Smell Gas • Do not try to light any appliance. • Do not touch any electrical switch, do not use any phone in the immediate area. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If  you cannot reach your gas supplier, call the fire department. 
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Troubleshooting Log Set Is Smoking/Sooting Excessively It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon (soot) where  flame contacts the logs.  The logs can be cleaned using a soft-bristle brush.  However, if soot is pro- duced where there is no flame impingement, one of the following may be the cause: Fireplace venting system not drafting properly: Make sure the damper is wide open at all times.   Preheat the flue in very cold weather by burning the log se
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        1d 2 1 1a 4 1b 1e 3 1 1 1c 10 9 14 5 15 12 7 16 17 8 13 6 7967 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products  at any time, without notice. OD24SHK Vented Gas Logs 7967  Ref. Description OD24SHK OD24SHK  1. Complete Log Set  20007970  P AR TS  1a. Top Log #3  5/04 NNS3  1b. Top Log (2) NNS4  1c. Rear Log  20007972  1d. Left Front Log 20007974  1e. Right Front Log 20007973  2.  Bag of Glowing Embers 43
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        LIMITED 2/20 YEAR WARRANTY For VERMONT CASTINGS Decorative Gas Appliances  CFM Specialty Home Products extends the warranties  ARE HEREBY EXPRESSLY INCLUDED. IN NO EVENT  specified in paragraphs A and B below with respect to its  SHALL ANY IMPLIED WARRANTY PRESCRIBED BY LAW  Vermont Castings Decorative Gas Appliances (the “Gas Ap- (NOTWITHSTANDING THE FOREGOING EXPRESS EX- pliance”), including CFM Specialty Home Products supplied  CLUSION) REMAIN IN EFFECT AFTER EXPIRATIONS OF  accessories and co