This manual should remain with the unit.                                                                                                                                                                                                                                                                                                                                        
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Table of Contents Part  –  Owner’s Manual Part II – Installation Instructions Introduction ............................................................................. 1 Safety Rules .........................................................................18  Read This Manual Thoroughly .........................................................1 Notice to Installer ..............................................................................18  Contents .........................................
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Introduction The operator (driver) is responsible for proper and safe use of the  INTRODUCTION vehicle and its equipment, and the safety of all vehicle occupants.  Thank you for purchasing this model by Generac Power Systems  We strongly recommend that the operator read this manual and  Inc. This model is designed and manufactured to supply electrical  thoroughly understand all instructions before using this equipment.  power for recreational vehicles. We also strongly recommend instructing othe
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Safety Rules  SA VE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be  copied and posted in potential hazard areas of the recreational vehicle. Safety should be stressed to   all operators and potential operators of this equipment. Study these SAFETY RULES carefully before installing, operating • Never sleep in the vehicle while the genset is running unless the  or servicing this equipment. Become familiar with this manual and vehicle has a working carbon mono
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Safety Rules EXPLOSION HAZARDS ELECTRICAL HAZARDS • Do not smoke around the generator. Wipe up any fuel or oil spills  • The generator covered by this manual produces dangerous  immediately. Ensure that no combustible materials are left in the  electrical voltages and can cause fatal electrical shock. Avoid  generator compartment, or on or near the generator, as FIRE or  contact with bare wires, terminals, connections, etc., while the  EXPLOSION may result. Keep the area surrounding the generato
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        General Information 1.1  GENERATOR IDENTIFICATION Please record the following information from the generator DATA DECAL or information decal.  1. Model Number ____________________ 2. Serial Number _________________  3. kW Rating _________________________ 4. Rated Voltage _________________  1. Generator Air Intake 10. Fuel Pump (Behind Access Panel)  2. Engine Start/Stop Switch 11. Fuel Filter (Side View)  3. Fuse 12. Oil Filter  4. Optional Remote Panel Receptacle (Side View) 13. Oil Drain Cap  
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        General Information 1.2 GENERATOR APPLICABILITY 1.4   GENERA TOR AC  These generators have been designed and manufactured for sup- CONNECTION SYSTEM plying electrical power for recreational vehicles. Do not modify the  This generator set is equipped with dual stator AC power windings.  generator or use it for any application other than for what it was  These two-stator windings supply electrical power to customer  designed. If there are any questions pertaining to its application,  electrical lo
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        General Information 1.5.5 GENERATOR Rated Maximum Continuous   The manufacturer does not recommend    AC Output (Gasoline) ...................................................3,600 Watts (3.6 kW)  using any gasoline containing alcohol (such   Rated Voltage ...............................................................................120 Volts AC as “gasohol”). If using any gasoline contain- Rated Maximum Continuous  ing alcohol, it must not contain more than    AC Current (Gasoline).............
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Operation This generator is not legal for sale in the state of California unless  2.2   OPTIONAL REMOTE all CARB evaporative emission requirements are adhered to, and  is not legal for sale in any other state unless certified low-per- START/STOP PANEL meation fuel line is used to supply the generator with gasoline.  A remote mounted Start/Stop Panel is available that allows start- Contact the California Air Resource Board or the Environmental  ing and stopping the generator engine conveniently f
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Operation 2.5 STARTING THE GENERATOR NOTE:  Any attempt to crank or start the engine  Read the vehicle manufacturer’s instructions.  The owner/ before it has been properly serviced with the    operator should become familiar with the vehicle in which this  recommended oil may result in an engine  generator is installed. Differences exist between vehicles. For  failure. example, some vehicles may use a transfer switch to isolate  dockside power from the generator, while other vehicles may  2.4.3 
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Operation Figure 2.2 – Low Oil Pressure and  2.7.1 LETTING THE ENGINE STABILIZE High Temperature Switches The generator supplies correct rated voltage only at the proper  governed speed. Some electrical appliances may be extremely  High Temperature Switch sensitive to voltage. Incorrect voltages can damage such appli- Low Oil Pressure ances. Switch If electrical loads are applied at reduced operating speeds, such  loads imposed on the engine when sufficient power is not available  may shorten en
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Maintenance Figure 2.4 – Solid State Voltage Regulator 3.1   CHECKING THE ENGINE OIL  LEVEL For oil capacities and requirements, see “Engine Oil Requirements”.  Check the engine crankcase oil level at least every eight hours of  operation, or before each use. To check the engine oil level, pro- ceed as follows (see Figure 3.1): 1. Be sure the generator is as level as possible. 2. Remove the dipstick and wipe it dry with a clean, lint-free  cloth. 3. Install and tighten the dipstick cap; then, re
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        e v o m e R G E N E R A C P o w e r S y o s t e m Maintenance Figure 3.1 – Oil Maintenance Features CONTROL CENTER C.B . ST A R T FUE L 30 A ST O P PR IM E FU S E 7.5 A S E R V IC E A C C ES S P A N EL AIR FILTER LOCATED BEHIND PANEL. MAINTENANCE SCHEDULE OIL LEVEL: CHECK DAILY AIR FILTER: CLEAN PREFILTER EVERY 100 HOURS. * REPLACE ELEMENT EVERY 250 HOURS. * OIL & OIL FILTER: CHANGE EVERY 100 HOURS. (OR ANNUALLY) * * PERFORM MORE OFTEN IN DUSTY CONDITIONS SPARK PLUGS: INSPECT & CLEAN PLUGS EVERY
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Maintenance  3.4  CLEAN AIR INTAKE Clean all foreign material from the air intake (Figure 3.3) at least   Sparking can occur if the wire terminal does  once every 100 hours of operation. Clean more often if neces- not fit firmly on the spark plug terminal end.    sary. If necessary, re-form the wire terminal to  Inspect the area around the generator exhaust muffler periodically  obtain a tight fit. and remove all grass, leaves, dirt, etc., from this area.  3.6  FUEL FILTER Figure 3.3 – Cleaning 
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Maintenance Figure 3.6 - Spark Arrestor 3.9.2 EVERY SIX MONTHS • Have the state of charge and condition checked. This should be  done with an automotive-type battery hydrometer.  Note: Servicing of the battery is to be performed or supervised by  personnel knowledgeable of batteries and the required precau- TAILPIPE tions. Keep unauthorized personnel away from batteries. P/N 0E0683 Damage will result if the battery connections are made in  reverse.  Do not dispose of the battery in a fire. The  
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Maintenance •  Where electrolyte contacts the eyes, flush  3.12.2 RETURN TO SERVICE thoroughly and immediately with water and  To return the unit to service after storage, proceed as follows: seek medical attention; and 1. Check the tag on the engine for oil viscosity and classification.  •  Spilled electrolyte is to be washed down with  Verify that the correct recommended oil is used in the engine  an acid neutralizing agent. A common practice  (see "Engine Oil Requirements"). If necessary, dra
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Maintenance 2. When valve clearance is correct, hold the pivot ball stud with  the allen wrench and tighten the rocker arm jam nut with a  crows foot. Tighten the jam nut to 65-85 inch-pounds torque.  After tightening the jam nut, recheck valve clearance to make  sure it did not change (Figure 3.8). Figure 3.8 — Tightening Jam Nut CROW'S FOOT  3.14  RV GENERATOR SERVICE  INTERVAL 50 Hours ....................................................Clean Spark Arrestor 100 Hours .........................
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Notes                                                                  16                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        PART II – INSTALLATION INSTRUCTIONS ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS  SHOULD ATTEMPT INSTALLATION!                                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Safety Rules   DANGER: For fire safety, installation of a generator into a recreational vehicle must comply strictly with  article 551, NFPA 70; ANSI C1-1975; AND, ANSI A119.2-1975/NFPA 501C “Standard for Recreational   Vehicles” (Part 3, “Installation of Electrical Systems”). In addition, installation must comply with the  manufacturer’s instructions and recommendations. GENERAL HAZARDS NOTICE TO INSTALLER These Installation Instructions have been published by the manu- • For safety reasons, th