Oil Furnace
Model 369AAN
USER’S
INFORMATION
MANUAL FOR
THE
OPERATION
AND
MAINTENANCE
OF YOUR NEW
OIL-FIRED
FURNACE
NOTE TO
INSTALLER:
This manual
must be
left with the
equipment user.
ملخص المحتوى في الصفحة رقم 2
WELCOME TO A NEW GENERATION OF COMFORT Congratulations! In light of rising energy costs, the 369AAN Multi- poise Oil Furnace is among the soundest investments today’s homeowner can make. Your new furnace is truly a tri- umph of technology in home heating. Its unique silencer within the heat exchanger, insulated cab- inet, and rubber blower mounts make it among the quietest units on the market. The combustion chamber is stainless steel for long life and it heats up quickly result
ملخص المحتوى في الصفحة رقم 3
FURNACE COMPONENTS 6 7 8 5 4 3 9 2 10 11 1 12 SEE NOTES: 13, 14 Left side, right side, or bottom. 2 1 Heavy-duty blower circulates air across the heat 8 Reversible door provides easy access to burner exchanger to transfer heat into the home. and controls. 2 9 Stainless steel combustion chamber/primary High-performance oil burner. heat exchanger. 10 Manual switch to allow user control of constant 3 Unique silencer system reduces combustion low-speed blower operation. noise. 11 Adjustabl
ملخص المحتوى في الصفحة رقم 4
Immediately call a qualified ser- minor personal injury or product IMPORTANT FACTS vice technician to inspect the fur- and property damage. Your furnace must have adequate nace and to replace any part of the airflow for efficient combustion ! WARNING control system, electrical compo- and safe ventilation. Do not For use with grade 2 Fuel Oil nents, and any oil control which enclose it in an airtight room or maximum. Do not use Gaso- has been under water. “seal” i
ملخص المحتوى في الصفحة رقم 5
CHECK AIR FILTER: Before When room temperature drops attempting to start your furnace, be below temperature selected on sure the furnace air filter is clean the thermostat, the furnace will and in place. See “Performing Rou- be switched on automatically. tine Maintenance” section in this When room temperature reaches manual. Then proceed as follows: the degree selected on the ther- mostat, the furnace will be switched off automatically. STEPS FOR STARTING Some thermostats have a
ملخص المحتوى في الصفحة رقم 6
2. Turn off all electrical power to To inspect, clean, and/or replace air ! WARNING filter, follow these steps: the furnace. (See Fig. 9.) Turn off all electrical power to 1. Turn off electrical supply to fur- furnace before performing nace. (See Fig. 11.) any maintenance or service on unit. Failure to take this 2. Remove filter from external fil- precaution may result in per- ter rack. sonal injury due to electrical 3. Inspect filter. If torn, replace it. shock. NOTE: If fi
ملخص المحتوى في الصفحة رقم 7
• Check flue and secondary tube pas- tions, and components for loose con- IF FURNACE FAILS TO sage ways including chimney — nections. OPERATE: clean if necessary. Follow this checklist step by step, • Examine the physical support of • Change oil filter. advancing to the next step only if the furnace. Support should be furnace fails to start. • Change nozzle. sound with no cracks, sagging, gaps, etc. around the base. • Check thermostat for proper tem- • Check and adjust combustion and draft.
ملخص المحتوى في الصفحة رقم 8
Cancels: OM16-7 OM16-9 © 1997 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 Printed in U.S.A. Catalog No. 5336-904 12-97 8