ملخص المحتوى في الصفحة رقم 1 
                    
                         
Operator’s 
Manual 
 
 
 
 
Serial # W 06060001 - on 
 
 
 
                                                                                  
If you accept the machine from the shipping 
Gas 
company, you are, in effect, saying that the 
machine is in good condition, and you must 
pay for the machine.  Belshaw cannot pay for 
shipping damage, because the freight company 
has accepted the machine from Belshaw in good 
condition, and is responsible for its safe delivery. 
Fryer 
For your protec
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        EQUIPMENT RECORD  Please provide the information below when you correspond with us about your machine.  Purchased by  _____________________________________________________________________  Installed by  ______________________________________________________________________  Date of Installation  ________________________________________________________________  Model number  ____________________________________________________________________  Serial number     0606  MN-1141EN  Belshaw Bros., Inc
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                         Contents    Sections  1 Installation 1  Conforming to Codes 1  Selecting a Workstation 1  Unpacking the Fryer 2  Initial Cleaning 2  Assembling the Fryer 2  Installing the Fryer 3  Moving the Fryer 4  2 Operation 5  Taking Safety Precautions 5  Frying Donuts 5  3 Cleaning 8  Removing the Shortening 8  Washing 9  Rinsing 10  4 Maintenance 11  5 Troubleshooting 17    Appendixes  A Pilot Module A-1  Checkout A-1  Troubleshooting—General A-4  Troubleshooting the Ignition System A-4      nd Belshaw 
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                          B Donut-Making Helps B-1  Tips on Making Quality Cake Donuts B-1  Calculating Correct Water Temperature B-2  Ratios of Plunger Sizes to Donut Weights B-2  Temperature Conversion B-2  C Parts Lists C-1     Limited Warranty Insert                                                                                                                                                                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Preface    The 718LCG, 724CG, and 734CG Gas Fryers are • To avoid damaging the machine, never  designed to fry cake and yeast-raised donut  use force to assemble, disassemble,  products.  Each must be bolted to a flat, dry  operate, clean, or maintain it.  floor.  The operator should stand opposite the  • Be careful never to get shortening,  flue stack.  water, or other materials on the floor.  If  The operator must work safely at all times and  anything does get spilled on the floor,  read this
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                          Contact Belshaw Brothers at 1-800-578- 2547 to obtain necessary parts and  instructions.                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                          1 Installation    In a prominent location, post instructions to be • The fryer must be isolated from the gas  followed in the event the user smells gas.  Obtain  supply piping system by closing its  this information by consulting your local gas  individual manual shutoff valve during any  supplier.  pressure testing of the gas supply piping  system at test pressures equal to or less than  1/2 psig (3.45 kPa).  FOR YOUR SAFETY  The fryer, when installed, must be electrically  Do not store or us
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                          The workstation should allow at least 2”/5 cm  Assembling the Fryer  clearance between the machine and all  1. Install the flue stack as follows:  construction, whether combustible or  noncombustible.  In addition, it should allow  a. Slide the flange on the bottom of the flue  access to the rear of the fryer for cleaning and  stack underneath the retaining strip on  servicing.  the flue base.  The mounting holes must  line up.  (See Figure 1-1.)  Unpacking the Fryer  b. Fasten the flue stack 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                          3. Put the heat shield and splash shield on the 4. Level the fryer.  Follow these steps:  fryer.  They slide over the flue stack, and the  a. Check to see if the fryer is level.  To do  back of the kettle slides between the heat  so, place a level across the top of the  shield and the splash shield.  The mounting  fryer cabinet.  holes in the heat shield and the fryer cabinet  b. If the fryer is not level, lift the fryer  must line up.  See Figure 1-2.  using a fork lift or pallet jack, and tu
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                          gas supply line on the fryer itself is  Moving the Fryer  1/2”/1.3 cm I.P.S.)  If you ever want to move the fryer to a different  b. Connect the fryer to the building’s gas  workstation, follow this procedure:  supply.  1. Turn off the fryer and disconnect it from the  c. Seal all threaded joints between gas  power source.  pipes with pipe joint compound.  You  2. Disconnect the machine from the gas supply.  must use a compound that resists the  action of liquefied petroleum (LP) gases.  3. Al
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                          Operation 2    proofer or feed table manual for complete  Taking Safety Precautions  installation and operation instructions.  In a prominent location, post information about  2. Make sure the drain valve is closed.  what to do if there is a gas leak.  Make sure that  3. Put enough shortening in the kettle to  all employees know what to do.  completely cover the burner tubes,  thermocouple, and high-temperature limit  WARNING  control probe.   Put shortening in the kettle using one of  To avoi
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                          4. Move the on/off switch to the OFF position. Use one of the following methods.  For  safety reasons, we recommend the first  5. Rotate the gas control knob counterclock- method, and discourage you from using any  wise to the ON position.  other method.  6. Move the on/off switch to the ON position.  • Use a Belshaw Shortening Melter (FM)   The yellow pilot light near the on/off switch  to melt shortening and transfer it to the  and the red pilot light on the fryer cabinet  kettle.  See the F
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                          CAUTION  To avoid damaging the machine, do not  operate the conveyor until all the  shortening has melted.  11. Continue supplying shortening to the kettle  as required.  Keep the kettle filled up to the  “Oil Level” marks on the side.  12. When you are done frying donuts, move the  on/off switch to the OFF position.    nd Belshaw Bros., Inc. • 1750 22 Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425  718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 7                           
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                          3 Cleaning    For your safety, observe the following warnings  Removing the Shortening  throughout the entire cleaning process.  WARNING  WARNING  To avoid being burned or electrocuted,  Thoroughly clean and dry the floor if  disconnect the fryer from the power source  shortening, water, or other materials are  before cleaning it.  spilled.  Materials spilled on the floor can  cause serious injury or loss of life.  1. Disconnect the machine from the power  source.    2. Let the shortening cool
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                          2. Connect the fryer to the power source.   WARNING  Move the on/off switch to ON.  Set the  temperature control to 200 °F/93 °C.  Keep  Do not allow the shortening to overflow the  the cleaning solution at this temperature for  containers.  Shortening will get on the  15-20 minutes.  floor, and if the shortening is not cool  3. Scrub the soiled parts while the solution is  enough, you may be burned.  hot.  Do not use any abrasive cleaners or  scrapers.    WARNING  WARNING  Thoroughly clean an
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                          WARNING WARNING  Do not allow the cleaning solution to Do not use plastic containers.  If the water  overflow the containers.  Cleaning solution is not cool enough, the containers will melt;  will get on the floor, and if the solution is possibly causing you to be burned, and  not cool enough, you may be burned. causing cleaning solution to get on the  floor.  8. When the draining is complete, close the  drain valve. 5. Open the drain valve and allow the water to  drain into the container.  9.
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                          Maintenance 4    SB-0308 rev 3    AFFECTS: OPEN KETTLE FRYERS  PURPOSE:  PROGRAMMING THE OGDEN ETR-9000 TEMPERATURE CONTROLLER  NOTE: Use Rev. 3 to correct existing open Kettle Fryer settings.  (SP1L set to 0 & PB set to 0)       Operator Interface:  The operator interface on the Ogden ETR-9000, Temperature Controller, consists of the following:  • A scroll key  used to select a parameter to be viewed or adjusted.  • Up  and down  arrow keys are used to increase or decrease the selected parame
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                          Menu Overview:  There are three main menus that contain parameters that require programming; they are User Menu,  Setup Menu, and Calibration Mode. The figure below (Figure 2) shows the sequence of operations  necessary to access the programming parameters in each menu.    Figure 2 - Menu Flow Chart  nd Belshaw Bros., Inc. • 1750 22 Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425  12 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers                                              
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                          Open Kettle Fryer Parameter Settings  Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory  settings. When installing a new controller 4 of the default setting must be changed to the Belshaw  Factory settings.   • Push and hold the scroll key  for 3 seconds, this will take you to the “SEt” menu.  • Push the scroll key  once to access the “LocK” parameter.  • Push the Up  or down  arrow keys to change “LocK” to “nonE”.  • Push the scroll key  to pa
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                          Table 1 - Parameter Descriptions  Set to   375ºF    set to  “uSEr”  after  setup            0ºF  410ºF        0ºF                nd Belshaw Bros., Inc. • 1750 22 Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425  14 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers