ملخص المحتوى في الصفحة رقم 1 
                    
                        Y/KSCF/C/HC18G High Efficiency
Cool Zone Series Gas Fryers 
Installation and Operation Manual 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Frymaster, a member of the Commercial Food Equipment Service Association, recommends 
using CFESA Certified Technicians. 
 
Price: $10.00
24-Hour Service Hotline 1-800-551-8633 
 
APR 2011 
*8196329*
                                                                                                                                                                         
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Please read all sections of this manual and retain for future reference.      NOTICE  This appliance is intended for professional use only and is to be operated by qualified  personnel only.  A Frymaster and Dean Factory Authorized Servicer (FAS) or other qualified  professional should perform installation, maintenance, and repairs.  Installation, maintenance,  or repairs by unqualified personnel may void the manufacturer’s warranty.  See Chapter 1 of  this manual for definitions of qualified pe
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                           DANGER  Adequate means must be provided to limit the movement of this appliance without depending  upon the gas line connection.  Single fryers equipped with legs must be stabilized by installing  anchor straps.  All fryers equipped with casters must be stabilized by installing restraining  chains.  If a flexible gas line is used, an additional restraining cable must be connected at all  times when the fryer is in use.     DANGER  The front ledge of the fryer is not a step.  Do not stand on t
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                            Y/KSCF/C/HC18G Cool Zone Gas Fryers        INSTALLATION & OPERATION MANUAL            TABLE OF CONTENTS                 Page #  1. INTRODUCTION    1-1  2. IMPORTANT INFORMATION    2-1  3. INSTALLATION INSTRUCTIONS    3-1  4. DAILY OPERATION    4-1  5. FILTRATION    5-1  6. PREVENTATIVE MAINTENANCE    6-1  7. TROUBLESHOOTING    7-1                                                                                                                                                                    
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS  FRYERS  CHAPTER 1:  INTRODUCTION      1.1  After Purchase    In order to improve service, have the following chart filled in by the Factory Authorized Servicer  who installed this equipment.      Authorized Servicer   Technician/FAS         Address       Telephone/Fax      Model Number      Serial Number      Gas Type       1.2  Ordering Parts    Customers may order parts directly from their local factory authorized servicer (FAS). If the  tel
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 1:  INTRODUCTION      1.3  Service Information    Call the Frymaster Service Hotline, 1-800-551-8633, for the location of your nearest factory  authorized servicer (FAS). To assist you more efficiently, always provide the service technician with  the model number, gas type, serial number, and the nature of the problem.      1.4  Controller Information    This equipment has been tested and found to comply with the limits for a 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 1:  INTRODUCTION      1.5  Safety Information (cont.)       DANGER  DANGER boxes contain information about actions or conditions, which may cause or result in  injury to personnel, may cause damage to your system, and/or cause your system to malfunction.        1.6  Service Personnel    A. Qualified and/or Authorized Operating Personnel: Qualified/authorized operating personnel  are those who have carefully read the informatio
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS  FRYERS  CHAPTER 2:  IMPORTANT INFORMATION      2.1  Receiving and Unpacking Equipment    A. Check that the container is upright. Use an outward prying motion - no hammering - to  remove the carton.  Unpack the fryer carefully and remove all accessories from the carton.  Do not discard or misplace these, as they will be needed.    B. After unpacking, immediately check the equipment for visible signs of shipping damage.  If  damage has occurred,
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 2:  IMPORTANT INFORMATION      2.3  Principles of Operation    The incoming gas flows through orifices and is mixed with air in the burners to create the correct ratio  for proper combustion.  The mixture is ignited at the front end of each heat tube by the pilot light.   Internal diffusers slow the flame as it goes through the burner tube.  This slow, turbulent flame  increases heat transfer to the walls of the tubes to heati
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 2:  IMPORTANT INFORMATION      2.5  Pre-Installation (cont.)     DANGER  This appliance must be installed with sufficient ventilation to prevent the occurrence  of unacceptable concentrations of substances harmful to the health of personnel in  the room in which it is installed.      B. Clearances:  The fryer area must be free of all combustibles. This unit is design-certified for  the following installations:    1. Commercial
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 2:  IMPORTANT INFORMATION      2.6  Air Supply and Ventilation     DANGER  Do not connect this appliance to the gas supply before reviewing each step in this  section.    A. Keep the area around the fryer clear to prevent obstruction of combustion and ventilation airflow  and to allow for service and maintenance. Always adhere to the following:    1. Do not connect this fryer to an exhaust duct.    2. Follow installation and a
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 2:  IMPORTANT INFORMATION      2.8 Restraining the Fryer     DANGER  No structural material on the fryer should be altered or removed to accommodate  placement of the fryer under a hood.  Questions?  Call the Frymaster Dean Service  Hotline at 1-800-551-8633.       1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the  top of the frypot to verify that the unit is level, both sid
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 2:  IMPORTANT INFORMATION       DANGER   Hot oil can cause severe burns. Avoid contact. Under all circumstances, oil must be  removed from the fryer before attempting to move it to avoid oil spills, falls and  severe burns. This fryer may tip and cause personal injury if not secured in a  stationary position.       DANGER  Do not attach an apron drain board to a single unit. The appliance may become  unstable, tip over, and ca
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS  FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.1  Installing the Fryer    Qualified, licensed, authorized installation or service personnel only (as defined in Section 1.6)  should perform the following:    1. Installation and service of Frymaster equipment;    2. Conversion of this appliance from one gas type to another.    Failure to use qualified, licensed, and/or authorized installation or service personnel to install,  convert to an
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.2  Leg and Caster Installation (cont.)    2. When positioning the fryer, gently lower it into position to prevent undue strain to the legs  and internal mounting hardware. If possible, use a pallet or lift jack to lift and position the  fryer. Tilting the fryer may damage the legs.    3. The rigid casters must be installed on the fryer rear channel assembly only.     B. Installation    1. R
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.3  Leveling the Fryer (cont.)    • Legs (Only)    1 1. Adjust leg height with an adjustable or 1 / -inch (27-mm) open-end wrench by turning  16 the hex bullet on the bottom of the leg.    2. The hex bullet is for minor leg height adjustment only.  Do not adjust more than 1 inch  (25 mm).    3. When leveling the unit, the leg body should be held firmly to keep the leg from bending  or rotati
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.3  Leveling the Fryer (cont.)    ANSI Z83.11/11a-(Latest Edition) requires a fryer be restrained to prevent tipping when  installed in order to avoid the splashing of hot liquid.  The means of restraint may be the  manner of installation, such as connection to battery of appliances or installing the fryer in an  alcove, or by separate means, such as adequate ties (chains, straps, etc.).  A 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.4  Gas Connections (cont.)     DANGER  "Dry-firing" your unit will cause damage to the frypot and can cause a fire.  Before  firing the unit, always ensure that melted shortening, cooking oil, or water is in the  frypot.       DANGER  Before connecting new pipe to this appliance, the pipe must be blown out  thoroughly to remove all foreign material.  Foreign material in the burner and gas  
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.4  Gas Connections (cont.)    A. Manifold Pressure: Your local service technician should check the manifold pressure with  a manometer.      1. Check the rating plate for manifold gas pressures. Natural gas units normally require 4"  W.C., and propane units normally require 11" W.C. gas pressure.      2. Confirm that the arrow forged into the bottom of the regulator body, which indicates ga
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                          Y/KSCF/C/HC18G HIGH EFFICIENCY COOL ZONE SERIES GAS FRYERS  CHAPTER 3:  INSTALLATION INSTRUCTIONS      3.4  Gas Connections (cont.)    2. For an appliance equipped with casters, the installation shall be made with a connector  that complies with the Standard for Connectors for Movable Gas Appliances, ANSI  Z21.69, or Connectors for Moveable Gas Appliances, CAN/CGA-6.16.  A quick- disconnect device that complies with the Standard for Quick-Disconnect Devices for Use  with Gas Fuel, ANSI Z21.41,