DRH-48N                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        A MESSAGE TO OUR CUSTOMERS Thank you for selecting this DCS Professional Built-in Patio Heater. Because of this appliance’s unique features  we have developed this Use and Care and Installation Guide. It contains valuable information on how to properly  operate and maintain your new appliance for years of safe and enjoyable use. To help serve you better, please fill out and submit your Ownership Registration by visiting our website at www. dcsappliances.com and selecting “Customer Care” on the h
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        CONTENTS SAFETY PRACTICES AND PRECAUTIONS  3-4 INSTALLATION       Locating Heater for Use    5  Installing the Heater    6  Gas Inlet Pressure    6  Clearance Specifications    7-11  Mounting     12  Electrical     12  Gas Piping     12  Ventilation     13      Leaking Test     13 USING THE HEATER  Lighting Instructions    14 WIRING/SCHEMATIC DIAGRAMS   15 SERVICE      16 WARRANTY      17-18   2                                                                                                      
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        SAFETY PRACTICES AND PRECAUTIONS  When properly cared for, your Built-in Patio Heater will give safe, reliable service for many years. However,  extreme care must be used since the heater produces intense heat and can increase accident potential. When  using this appliance, basic safety practices must be followed, including the following: ■ Read this Use and Care and Installation Guide carefully and completely before using your heater to reduce the  risk of fire, burn hazard or other injury.  Be
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        SAFETY PRACTICES AND PRECAUTIONS ■  Clean the heater with caution. Avoid steam burns; do not use a wet sponge or cloth to clean the heater while it  is hot. Some cleaners produce noxious fumes or can ignite if applied to a hot surface.  ■  Be sure all heater controls are turned off and the heater is cool before using any type of aerosol cleaner on or    around the heater. The chemical that produces the spraying action could, in the presence of heat, ignite or  cause metal parts to corrode. ■ Do 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        LOCATING HEATER FOR USE This outdoor heater is used primarily for temporary heating of outdoor patios, decks, spa and pool area, and work  areas. This heater is not intended for indoor use or in an enclosed area. Always ensure that adequate fresh air  ventilation is provided. WARNING!   Never operate in an explosive atmosphere. Keep away from areas where gasoline or other flammable liquids or  vapors are stored or used.   DEFINITION OF COMBUSTIBLE MATERIAL - Any materials of a building structure
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        INSTALLATION INSTALLING THE HEATER: The Built-in Patio Heater provides radiant warmth indoors (commercial applications only) or outdoors with a  powerful 56,000 Btu/hr natural gas.  All units are equipped with hot surface ignition and 100% shutoff valve for  safety. Built-in Patio Heaters to be installed in Aircraft Hangers must be installed in accordance with American  National Standards for Aircraft Hangers, ANSI/NFPA No. 409.  Heaters to be installed in public garages must be  installed in ac
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        INSTALLATION CLEARANCE SPECIFICATIONS 0 0 0 & 45 INSTALLATION  MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL. FRONT VIEW Wall Wall (Combustible (Combustible Surface) Surface) Heater Mounting Body Assy. 18" 48" 18" min. min. 96" min. Make sure the heater is  level (see Warning on  page 6). FLOOR 7                                                                                                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        INSTALLATION CLEARANCE SPECIFICATIONS 0 0 INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL. SIDE VIEW 1/2" Combustible Conduit Surface Gas Pipe Gas Shut-off (installer (installer supplied)  Valve  supplied) Four Bolts Two   (installer supplied) On Each Side (installer supplied) 16" min. Drip Leg Utilize 2  bolts (min) with 1/8” NPT per bracket plugged test Utilize 2  gage connection bolts (min) per bracket. 7-3/4" 18"min. 10-1/4" 120" min. 96" min. Note: Stainless steel hardware is highly
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        INSTALLATION CLEARANCE SPECIFICATIONS 0 45 INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL. SIDE VIEW Combustible 1/2"  Surface Conduit Gas Pipe 4 Bolts per (installer (installer supplied)  supplied) Bracket (installer supplied) 25" Gas Shut-off min. Valve (installer supplied) Utilize 2  Bolts (min) 12" Drip Leg per Bracket with 1/8” NPT REF. plugged test gage connection 18" min. 0 45 max. 130" min. 96"  min. Note: Stainless steel hardware is highly    recommended. Bolts in the wall     
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        INSTALLATION CLEARANCE SPECIFICATIONS 0 0 INSTALLATION  MINIMUM CLEARANCES TO NON-COMBUSTIBLE MATERIAL. SIDE VIEW  Four Bolts Per Bracket (installer supplied) Non Combustible  Utilize 2  Gas Pipe Surface bolts (min) (installer supplied) per bracket Gas Shut-off Valve (installer supplied)  1/2" Conduit (installer  supplied) Drip Leg with 1/8” NPT plugged test gage connection 18"min. 96" min. Note: Stainless steel hardware is highly    recommended. Bolts in the wall     should be secured to the wa
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        INSTALLATION CLEARANCE SPECIFICATIONS 0 45 INSTALLATION MINIMUM CLEARANCES TO NON-COMBUSTIBLE MATERIAL. SIDE VIEW  Four Bolts                                  Per Bracket (installer supplied) 1/2" Conduit (installer supplied) Non Combustible  Surface  Utilize 2  Gas Pipe  Gas Shut-off bolts (min) (installer supplied)   Valve per bracket. (installer supplied) Drip Leg with 1/8” NPT plugged test gage connection 18"min. 0 45 max.  96"   min.   Note: Stainless steel hardware is highly    recommended
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        INSTALLATION Do not locate either the gas or electrical supply line directly over the top of the heater, due to the extreme heat  that may cause overheating or damage. The heater must be installed in a location that is accessible for service.  The heater must be installed in a way that doesn’t restrict fresh airflow to the unit. The heater cannot be installed  in a recessed area. Doing so may cause poor performance and heat damage to the surrounding area. MOUNTING Each heater must be installed s
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        INSTALLATION Important! VENTILATION A minimum building ventilation rate of 4 CFM per 1,000 BTU’s of installed heater input must be provided.  This  rate of ventilation may be obtained through either gravity or mechanical ventilation of the building.  In con- junction with building ventilation system, adequate fresh air into the building must be provided through fresh  air inlets and/or building inlets.  It is recommended local code be checked to assure the ventilation system and  heat installati
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        USING THE HEATER LIGHTING INSTRUCTIONS TO LIGHT HEATER Upon installation of the heater and completion of the gas line and electrical supply to each heater, follow the  steps below for  Lighting Instructions.  Lighting instructions are also provided on the control panel of the heater. Turn gas and power to “ON”.  The burner should light within the first 4 seconds.  If not, the flame sensor will shut  off the mini-igniter.  The unit will attempt to light 3 times before “locking out”.  During initi
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        WIRING/SCHEMATIC DIAGRAMS FLAME SENSOR  GAS VALVE #2 #1 SHORT TO BYPASS FLAME SENSOR N 1.  PUR - FLAME SENSOR 2.  GRN - GROUND 3.  BLU - GAS VALVE (TERM #1) 120 VAC 4.  ORG - THERMOSTAT 24 VAC  60 Hz FUSE 5.  (BLANK) 10 AMP - 32 VOLT 6.  BLK - 24 VAC L1 7.  RED - IGNITER WIRING SCHEMATIC IGNITER GAS 2 VALVE 1 FLAME SENSOR SW L1 N  MINI GROUND 24 VOLT AC IGNITER LUG TRANSFORMER 1 2 3 4 5 IGNITION 6 MODULE 7 WIRING / COMPONENT DIAGRAM 15 FUSE                                                        
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        SERVICE HOW TO OBTAIN SERVICE: For warranty service, please contact DCS Customer Care at (888) 936-7872, or go to our website at www.dcsap- pliances.com and choose “customer care” to find your nearest Authorized Service Center.  Before you call, please  have the following information ready: ■ Model Number (located on right side near the gas inlet) ■  Serial Number (located on right side near the gas inlet) ■  Code (located on right side near the gas inlet) ■  Date of installation ■  A brief desc
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        WARRANTY LIMITED WARRANTY When you purchase a new DCS Professional Built-in Patio Heater you automatically receive a One Year Limited  Warranty covering parts and labor for the entire product, and a Five Year Limited Warranty on all stainless steel  components (excludes emitter screen, surface corrosion and discoloration) for servicing within the 48 mainland  United States, Hawaii, Washington D.C. and Canada. In Alaska, the Limited Warranty is the same except that you  must pay to ship the Produ
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        WARRANTY (CONTINUED) D.  The cost of repairs carried out by non-authorized repairers or the cost of correcting such unauthorized repairs. E.  Travel Fees and associated charges incurred when the product is installed in a location with limited or restricted  access (i.e. airplane  flights, ferry charges, isolated geographic areas). F.  Normal recommended maintenance as set forth in the Product’s Use and Care Guide. If you have an installation problem contact your dealer or installer. You are resp