ملخص المحتوى في الصفحة رقم 1 
                    
                        OUTDOOR GAS 
FIREPLACE 
 
OWNER’S OPERATION AND INSTALLATION MANUAL 
AL500HYLA 
50,000 BTU/Hr 
Manually Controlled 
     IMPORTANT: Read this 
   WARNING: If the information in this manual is 
 owner's manual carefully and 
not followed exactly, a fire or explosion may result 
 completely before trying to 
causing property damage, personal injury, or loss 
assemble, operate, or service 
 
of life. 
this heater. 
 
    FOR YOUR SAFETY: 
Do not store or use gasoline or other flammable 
      WARNI
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        SAFETY INFORMATION  PRODUCT IDENTIFICATION       1. Check the heater completely and thoroughly for    damage. DO NOT run a damaged heater.    2. DO NOT alter the heater or operate a heater that    has been modified from its original condition.    3. Use only propane gas.  4. Use only vapor withdrawal propane gas. If any   question, contact your LP dealer.    5. Do not use this heater as a wood-burning heater.    Use only the logs provided with the heater.    6. Inspect hose assembly before each 
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        PRODUCT FEATURES  Caution: Some of the steel edges may  SAFETY PILOT  be sharp. Please use caution when  The heater has a pilot with a safety shutoff system.  assembling the unit.  The safety pilot is a required feature for outdoor  heaters. It shuts off the heater if flame is extinguished INSTALLATION INSTRUCTIONS:  by rough wind. 1. Remove grate out of base and set flat on floor.  2. Take log foam package out of base. Please note  PIEZO IGNITION SYSTEM  This heater has a piezo igniter. This sy
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        INSTALLATION INSTRUCTIONS  7. Attach the four columns to the burner plate with              Continued  M4  10 screws provided. Do not tighten at this  time. (See FIG.7)  5. Install logs 1,2,3,4,5 by inserting each log   screw into holes of corresponding grate   branch . Make sure each log is placed in   proper sequence.(See FIG 5.)    Note: If the log is too loose or the screw can’t be   pulled down after inserting the log screw, screw the   nuts to adjust the clearance between nuts and logs.   
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        8. Set the top panel in place on the columns and 12. From the outer side, use M5  10 screws to  secure with M4  10 screws provided. Do not fasten the fixing hoop on the right and left support.  Fasten the other side of the fixing hoop after the   tighten at this time. (See FIG.8)  cylinder is in place.  (See FIG.11)      Figure 11-The fixing hoop installation Figure 8-Top panel installation  CONNECTING TO GAS SUPPLY  9. Attach the screens to columns with M4  10  Note: The installer must supply a
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                         CONNECTING TO GAS SUPPLY OPERATING HEATER              Continued Continued  TO TURN OFF HEATER:  FUEL REQUIREMENTS:  1. Turn gas control knob to the “OFF” position.   Connect regulator/hose with standard 20-pound  2. If heater is not to be used, shut off cylinder valve.  LP cylinder coupler.   3. Do not attempt to relight heater within 5 minutes   Call the LP gas supplier to inspect the cylinder.  after the propane cylinder valve has been closed.  Do not use a damaged LP gas cylinder.  RESTART 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        PILOT AND BURNER:  MAINTENANCE AND STORAGE Clean dust with a vacuum cleaner.  Continued    11. Spiders and insects can nest and live in outdoor BURNER AIR INLET HOLE:  appliances, especially in the burners and orifices. We recommend that you clean the unit every three  This will interrupt the normal flow of LP gas to the months or after 2500 hours operation. We also  heater and can be a very dangerous situation. recommend that you keep the burner tube and pilot  Inspect for insect infiltration o
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                          PARTS NOT UNDER WARRANTY:  SERVICE INDICATIONS:    A hazardous condition may result if a heater has  Contact authorized dealers of this product or Parts Central if    been modified or is not functioning properly. When  they can't supply original replacement part(s) Call PRO-COM's  the heater is working properly:  Parts Department at 1-877-886-5989 for referral information.  1. The flame is contained within the heater.  When calling PRO-COM, have ready  2. The flame is essentially yellow.   Mod
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                          PARTS LIST  This list contains replaceable parts used in your heater. When ordering parts, follow the  instructions listed under Replacement Parts on page 7 of this manual.  HP500MA       KEY PART   DESCRIPTION QTY.   NO. NUMBER   AB01001 Top Panel 1  1   2 AB29001 Mesh Screen  2    3    Mesh Screen 2  AB29002   4 AL002-01 Column 6   Burner Fixing Plate 6  5 AL009-01    6  6 AL01002 MID Base   7 Support Part 1  AL033-01   8 AL013-01 Support 1    AL011-01 Door 2  9   AB01004 Base 1  10   AB0100
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        ILLUSTRATED   PARTS BREAKDOWN  AL500HYLA                               10                                                    AL058-01                                                                                                                                                                                                                                                                                                                                                                               
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                          PARTS LIST  This list contains replaceable parts used in your heater. When ordering parts, follow the  instructions listed under Replacement Parts on page 7 of this manual.  HP500MA       KEY PART   DESCRIPTION QTY.   NUMBER  NO.    1  1 NBY50-200A1 Burner    NDW-L600×4 Safety Pilot 1  2    1  3 AB31002 Safety Pilot Inlet Tube ASM    Control Valve 1  4 NV2020-1217    AL031-01 Washer 1  5    6 AB31001 Gas Outlet Tube ASM 1    Control Valve Main Inlet Nut 1  7 AL030-01    8 AL016-01 Control Cabi
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        ILLUSTRATED   PARTS BREAKDOWN  AL500HYLA                                                            12                                                   AL058-01                                                                                                                                                                                                                                                                                                                                                   
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        This list contains replaceable parts used in your heater. When ordering parts, follow the  LOGS LIST  instructions listed under Replacement Parts on page 7 of this manual.  AL500HYLA     KEY PART  DESCRIPTION QTY.  NUMBER  NO.  1  1 AL057-01 Log 1  AL057-02 Log 2 1  2  1  3 AL057-03 Log 3  Log 4 1  4 AL057-04  Log 5 1  5 AL057-05  6 AL057-06 Log 6 1  AL057-07 Log 7 1  7  8 AL057-08 Log 8 1  1  9 AL057-09 Log 9  1  10 AL057-10 Log 10                                     13                         
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                         LOGS LIST    AL500HYLA   NANJING PRO-COM ELECTRIC APPLIANCE CO.,LTD.  #6 CHUANGYE ROAD, HIGH NEW TECH. ZONE,   NANJING, 210061, CHINA     PRO-COM Toll-Free number: 1-877-886-5989                                                            14                                                 AL058-01