                        INSTALLATION INSTRUCTIONS
TM
ADAGIO™ Direct-Vent
Gas Fireplaces
P/N 850044M   Rev. F   01/2011 
MODELS
This manual is one of a set of two supporting this product.  
MILLIVOLT: ELECTRONIC:
Refer to P/N 875037M for Care and Operation Instructions.
 ADAGIO-MN ADAGIO-EN
Ce manuel est disponible en francais, simplement  
en faire la demande. Numéro de la pièce 850044CF.
 ADAGIO-MP
Portland
US
OTL Report No. 116-F-48-5
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for f
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        PACKAGING GENERAL INFORMATION TABLE OF CONTENTS  Packaging .........................................Page 2 The assembled vented gas fireplace heater is  packaged with: Introduction ......................................Page 2       WARNING  General Information ..........................Page 2 Young children should be care- 1 - One log set located in firebox. Requirements for Commonwealth 2 - One envelope containing the literature fully supervised when they are    of Massachusetts ...............
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Note: Installation and repair should be done The appliance, when installed, must be electri-        WARNING by a qualified service person. The appliance cally grounded in accordance with local codes  should be inspected before use and at least  or, in the absence of local codes, with the  Improper installation, adjust- annually by a professional service person.  National Electrical Code, ANSI/NFPA 70-latest  More frequent cleaning may be required  ment, alteration, service or  edition, or the Ca
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        I  O  O  L  I  P  T  O  i t  T P T H T P T H  L  I  P  F  L  F  O  Gas Pressure - All Models Orifice Sizes -  Sea Level to High Altitude HI/LO Variable  (All Models) Inlet Pressure  Manifold  Flame Height  Tap Tables 2 and 3 show the appliances' inlet and Pressure Tap Adjustment manifold gas pressure requirements: These appliances are tested and approved for  installation at elevations of 0-4500 feet (0-1372  meters) above sea level using the standard  HI Inlet Gas Supply Pressure  burner orific
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        COLD CLIMATE INSULATION TOP VENT INSTALLATIONS For cold climate installations, seal all cracks  around your appliance with noncombustible  material and wherever cold air could enter  the room. It is especially important to insulate  outside chase cavity between studs and under  floor on which appliance rests, if floor is above  ground level.  Gas line holes and other open- ings should be caulked or stuffed with unfaced  ROOM DIVIDER APPLICATION VER TICAL VENT  fiberglass insulation.  HORIZONT AL
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        VENT TERMINATION CLEARANCES Vertical Vent Termination  Clearances Termination Heights For Vents  These instructions should be used as a  TERMINATION HEIGHTS FOR VENTS ABOVE Above Flat Or Sloped Roofs FLAT OR SLOPED ROOFS  guideline and do not supersede local codes  Ref. NFPA 54 / ANSI Z223.1 Horizontal Overhang  in any way. Install vent according to local  Roof Pitch * Feet * Meters 2 FT  codes, these instructions, the current National Vertical  MIN.  2 FT MIN. Wall  Flat to 6/12 1.0 0.3 Fuel Ga
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        V EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS  NOTE:  Local Codes Or Regulations May Require Different Clearances. * See Item D in the Text Below. N P N NOTE:  Location Of The Vent Termination Exterior Wall Inside Must Not Interfere With Access To The Corner Detail O Electrical Service. *18” V V G Q Horizontal Termination V 6” Ventilated Soffit A Inside Corner = 9” in U.S. � A = 12” in Canada Detail D H 3 ft. B B D E C X � A � A V V L Fixed Operable V Closed Window 3 ft. Window V
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        MINIMUM CLEARANCES TO  Do not insulate the COMBUSTIBLES space between the MODELS appliance and the Adagio-MN area above it. Appliance And Vent Clearances Adagio-MP Adagio-EN Header The appliance is approved with zero clearance to com- 4” �  Combustible Shelf Height bustible materials on all sides (as detailed in Table 5),  (102mm)  Inches (millimeters) with the following exception: When the unit is installed  Drywall with one side flush with a wall, the wall on the other  Top Vent - with One 90 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        TYPICAL INSTALLATION SEQUENCE Step 1. FRAMING        WARNING  The typical sequence of installation is outlined Frame these appliances as illustrated in Figures  Failure to position the parts in  below.  However, each installation is unique 12 and 14 on Pages 10 and 12 (Figure 14  accordance with these diagrams  and may result in variations to the steps applies to corner framing installations only).   or failure to use only parts specifi- described. All framing details must allow for a minimum  c
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        FIREPLACE AND FRAMING SPECIFICATIONS Framing Dimensions - All Models Framing With Platform Inches (millimeters) A B C D 10¹⁄₂ (267) VENT FRAMING - in. 22-1/8 40-1/4 15-3/4 44-1/8 TOP VENT WITH ONE 90° ELBOW mm 562 1022 400 1121 Framing should be constructed of  2x4 or larger lumber *  D shown here is not dimensioned to the vertical center of  the horizontal framing. This is to allow for the required 4"  clearance above the vent and the 1" required clearance  below the vent. This does not include
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Facade (Required) * (arched style shown) FACADE SPECIFICATIONS Arch Facades** 1/2” (13mm) -  Black and Brushed Nickel Finishes 1-1/2” (38mm) Cat.  Model Description No. H5773 ADAGIO-AG Arch Black H5774 ADAGIO-PF Arch Br. Nickel ** A filigree inset kit is also required  (sold separately).  See Care and  Operation Manual for ordering  20-1/4” 38-1/2” information. (514) (978) 1/2” (13) 14-13/16” (376) 26-3/4” (680) Gated Facades Cat. No. Model Description Copper and Iron Gates H5775 ADAGIO-IG Iron 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Top Vent With Horizontal Termination In A Corner Corner Framing Dimensions - All Models A B C D E in. 22-1/8 41-5/8 29-1/2 10 20-7/8 D mm 562 1057 749 254 530 7 (178) uWhen installing in a corner configuration, one of  the rear stand-offs will need to be removed. C � E A Figure 14 - Corner Framing with Square Termination (SV4.5HT-2) B Back wall of chase/enclosure Inches (including any finishing materials) (millimeters) Never use galvanized or plastic pipe.  Refer  Step 2. ROUTING GAS LINE Notes:
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Step 3. INSTALL THE VENT SYSTEM wall (such as a chase). There is no requirement  Use only approved venting components.   for inspection openings in the enclosing wall  See Approved Vent Components on  General Information at any of the joints in the vent pipe.  Page 2. These instructions should be used as a  Select Venting System - Horizontal or Verti- These fireplaces must be vented directly  guideline and do not supersede local codes  cal to the outside. in any way. Install vent according to lo
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        VERTICAL TERMINATION SYSTEMS (ROOF) VENT SECTION LENGTH CHART VENT SECTION LENGTH CHART See Figures 16, and 24 through 26 on Nominal 6 12 24 36 48 Nominal Section 6 12 24 36 48 T VENT SECTION LENGTH CHART T Length (inches) Section Length O Pages 14 and 17 and their associated Vertical     O T Nominal Section 62142638 4 T (inches) VENT SECTION LENGTH CHART T O Length (inches) Vent Tables which illustrate the various vertical  Net Section 4 ½ 10 ½ 22 ½ 34 ½ 46 ½ A T Nominal A T Net Section Length 
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        B. Attach vent components to appliance Push the vent component against the previous  Vertical (Offset) Installation - Secure Vent SV4.5 direct-vent system compo- section until it fully engages, then twist the  Analyze the vent routing and determine the nents are unitized concentric pipe components component clockwise running the dimples down  quantities of vent sections and number of el- featuring positive twist lock connections (see and along the incline channels until they seat at  bows requir
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        One method of support is by utilizing field pro- K. Install the vertical termination - The final  step involves installation of the SV4.5CGV-1  vided support straps (conventional plumber's  Vertical Termination.  Extend the vent sections  tape). Secure the plumber's tape to the framing  to the height as shown in the "Vertical vent ter- members with nails or screws. Loop the tape  mination section" on Page 6.  The SV4.5CGV-1  around the vent, securing the ends of the tape C Vertical Termination (
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                           VERTICAL VENT FIGURES/TABLES  Table A Notes:  H Maximum V Minimum •	 Secure	 	 V ent™	 	 (rigid	 vent	 pipe)	 	 is	 shown	 H in	 the	 Figures;	 Secure	 Flex™	 (flexible	 vent	 feet (meter) feet (meter) pipe) may also be used. 5 (1.524) Elbow Only •	 It	 is	 ver y	important	 that	 the	 horizontal/in- clined run be maintained in a straight (no  5 (1.524) 1 (0.305) u Ceiling Firestop /  dips) and recommended to be in a slightly  Spacer (SV4.5VF) 10 (3.048) 2 (0.610) elevated plane, in a directio
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        HORIZONTAL (OUTSIDE WALL) TERMINATION  SYSTEM Support the vertical portion of the venting system  every 8 feet (2.4m) above the fireplace vent outlet. Support Brackets Building See Figures 27, and Figures 30 to 33 on Pages  Support Horizontal / Inclined Run SV4.5 HT-2 18, 20 and 21 and their associated Horizontal Framing Termination Vent Table which illustrate the various horizontal  SV4.5E90 Shown venting configurations that are possible for use  Elbow with these appliances.  Secure Vent™ pipe 
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        J. Assemble vent run to exterior wall - If not  To help minimize water infiltration it is previously measured, locate the center of the  recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior vent at the exterior wall.  Prepare an opening as  side of the wall. described in Step B.  Assemble the vent system  SV4.5 HT-2 to point where the terminus of the last section is Termination 7" (178) located relative to the exterior surface to which  12¹⁄₈" 10¹⁄₂" (308 mm) (267mm) the t
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        See Table 8  as an aid in venting component selection for a particular  range of exterior wall thicknesses. Table C H Maximum V Minimum  Venting Components Required for Various Exterior Wall Thick- feet (meter) feet (meter) nesses, when using Square Termination Kit (SV4.5HT-2) 3 (0.914) Elbow Only Vent Components Required Exterior Wall Thickness - inches (mm) Termination Kit Only 6 to 9-1/4 (152 to 235) Square termination  (SV4.5HT-2) shown.  Termination Kit and  6 In. Vent H  10-3/4 to 14 (273