BLOOMFIELD INDUSTRIES
OWNERS MANUAL 
2  ERIK CIRCLE, P. O. Box 280
For 
Verdi, NV  89439
 
Customer Service (775) 345-0444 Ext.502
fax: (775) 345-0569
 
www.wellsbloomfield.com
 
 
MODULAR 
BREWING SYSTEMS 
 
MODELS 
 
POUR OVER     AUTOMATIC     AUTOMATIC 
UNITS                UNITS               UNITS 
                                                       WITH FAUCET 
8542                8541                8540 
8543                8573                8572 
8571                         
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        WARRANTY STATEMENT  All electrical equipment manufactured by BLOOMFIELD    It also does not apply if the serial nameplate has been        INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service.   workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products  installation or eighteen (18) months from the date of shipment are based upon the limitations in this warranty.  Seller
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        TABLE OF CONTENTS  WARRANTY     STATEMENT                                            xi  Thank You for purchasing this  SPECIFICATIONS                                                               1  Bloomfield Industries appliance.    FEATURES & OPERATING CONTROLS                           2  Proper installation, professional  PRECAUTIONS & GENERAL INFORMATION                   3  operation and consistent  AGENCY APPROVAL INFORMATION                               3  maintenance of this applianc
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        FEATURES AND OPERATING CONTROLS  Fig. 1  Features & Operating Controls  2                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        PRECAUTIONS AND GENERAL INFORMATION  WARNING:  Electric Shock Hazard  All servicing requiring access to non-insulated components must be performed by qualified  service personnel.  Do not open any access panels which require the use of tools.  Failure to  heed this warning can result in electrical shock.    WARNING:  Injury Hazard  All installation procedures must be performed by qualified personnel with full knowledge of all  applicable electrical and plumbing codes.  Failure could result in pr
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        INSTALLATION INSTRUCTIONS  READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION  IMPORTANT:  REFER TO EXPLODED VIEWS PAGES 18 thru 22 FOR  To enable the installer to make  COMPONENT NAMES/NUMBERS    a quality installation and to   Unpack the unit.  Inspect all components for completeness and  minimize installation time, the  condition.  Ensure that all packing materials have been removed  following suggestions and tests  from the unit.   should be done before the        actual unit installation 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        INSTALLATION INSTRUCTIONS (continued)  NSF requires that the brewer be able to be moved for cleaning NOTE:  This equipment must be  installed to comply with           underneath.  A flex line or loops of copper tubing will satisfy this  applicable federal, state and   requirement. See Figure 2 below.  local plumbing codes and         ordinances.          WARNING ELECTRIC    SHOCK HAZARD:         Brewer must be properly    grounded to prevent possible    shock hazard.  DO NOT           assume a p
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        OPERATION  Fig. 4  Brewer Operation Diagram  IMPORTANT: A. START-UP    Tank must be full of water        For initial start-up, or if the brewer has not been used for an          before connecting brewer        extended period of time:   to electrical power.       Heating elements will be        ♦  Be sure spray disk and brew gasket are properly installed in the    damaged if allowed to             brew head.    operate without being fully        ♦  Be sure the water supply is properly connected 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        OPERATION (continued)  WATER HEATER  HI-LIMIT   THERMOSTAT Water temperature is sensed by a             thermobulb inserted into the water tank.  This  temperature signal is fed to the thermostat,  which controls line power to the heating     THERMOBULB element.    The setpoint temperature is adjustable at the  thermostat.  HEATER   THERMOSTAT ELEMENT The element is protected from over- temperature by a hi-limit thermostat.      Fig. 5  Heat Control Diagram      WATER FLOW    POUR-OVER FEATURE  
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        BREWING COFFEE  CAUTION:   B. PREPARATION    Burn Hazard         Place one (1) genuine Bloomfield  PAPER   FILTER       paper filter in the brew chamber.  Exposed surfaces of the        Add a pre-measured amount of  brewer, brew chamber and        fresh coffee grounds.  decanter may be HOT to  BREW       Gently shake the brew chamber to  CHAMBER the touch, and can cause         level the bed of grounds.  Slide the   serious burns.        brew chamber into place under the           brew head. Fig
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        CLEANING INSTRUCTIONS  CAUTION:  PROCEDURE:  Clean Coffee Brewer  Burn Hazard      PRECAUTIONS:   Disconnect brewer from electric power.                                 Allow brewer to cool.  Brewing and serving    temperatures of coffee are      FREQUENCY:       Daily  extremely hot.    Hot coffee will cause  TOOLS:                 Mild Detergent, Clean Soft Cloth or Sponge  serious skin burns.                                Bristle Brush.          CAUTION:  1.   Disconnect brewer from electric
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        TROUBLESHOOTING SUGGESTIONS  SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY      Water won’t heat Brewer unplugged or circuit Check power supply cord   breaker tripped Check / reset circuit breaker       Thermostat set too low Set for desired temperature        Hi-Limit thermostat tripped Allow to cool    Reset hi-limit (8786, 8788)       Damaged internal component or Examine wiring & connectors,    wiring thermostat and heating element     Repair/replace as needed         Pourover - no water or too li
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        SERVICING INSTRUCTIONS  ACCESS PANELS  CAUTION    Electric Shock  Each warmer plate has a center stud which screws into a  Hazard  bracket.  Remove warmer plates by turning counter-clockwise.      Opening access panels or      Solenoid door is held by two screws and a retaining lip.  removing warmer plates on this    brew may expose uninsulated  Front Panel (In-Line Models) and Top / Rear Panel (3-Station  electrical components.  Models):  Disconnect brewer from                     a.  Remove wa
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        SERVICING INSTRUCTIONS (continued)  CAUTION  TEMPERATURE ADJUSTMENT  Electric Shock    Hazard Unplug power cord or turn circuit breaker OFF.  Remove top   panel.    These procedures involve        Pull vent tube out of tank lid and insert a thermometer of known  exposed electrical circuits.  accuracy in vent hole.  Reconnect brewer to electrical power.    These procedures are to be     performed by qualified            technical personnel only.    DIAL-TYPE   THERMOSTAT THERMOMETER   ADJUSTING  
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        SERVICING INSTRUCTIONS (continued)  TIMER ADJUSTMENT   IMPORTANT:  Water pressure    must be between 20 p.s.i and  The amount of water dispensed automatically during a brew cycle  90 p.s.i. flowing pressure.          is controlled by the timer.    If water pressure exceeds this  Place empty decanter under brew chamber.  Press BREW        value, or if water pressure      button.  Brewer should dispense one decanter of water.  To      varies greatly, a pressure    adjust amount:  regulator must be
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        SERVICING INSTRUCTIONS (continued)    REPLACE SOLENOID      Symptom:  Automatic brewer will not flow water; or,    automatic brewer drips continuously from brew head.        Unplug power cord or turn circuit breaker OFF.  Turn OFF and    disconnect water supply from brewer inlet fitting.      A.  (OLD-STYLE)           Remove hex nut holding inlet fitting into back of brewer.               Remove two screws holding access door in place. Remove           access door.  Remove front panel.          
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        SERVICING INSTRUCTIONS (continued)  REPLACE TIMER ASSEMBLY  IMPORTANT:  When replacing    water faucet coil, also replace  Unplug power cord or turn circuit breaker OFF.    seal gaskets.  Remove front panel.  Remove knob and three screws holding    timer to bracket.  Disconnect wiring to timer.        Reassemble in reverse order.    Adjust timer as described on page 13        REPLACE HOT WATER FAUCET COIL      Symptom:  Brewer drips continuously from brew head, except    when faucet valve is tur
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        SERVICING INSTRUCTIONS (continued)  CAUTION -   PROCEDURE:  Delime the Water Tank   CHEMICAL BURN    PRECAUTIONS:   Disconnect brewer from electric power.   HAZARD                                Allow brewer to cool.  Deliming chemicals are caustic.     Wear appropriate protective  FREQUENCY:       As required (Brewer slow to heat)  gloves and goggles during this    procedure.  TOOLS:                 Deliming Solution  Never siphon deliming                                     Protective Gloves, 
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        SERVICING INSTRUCTIONS (continued)  7.   Set the tank back into the brewer.  Reassemble the tank lid to NOTE:  Normally, silicone        the water tank.  Make sure the gasket is properly in place,  hoses do not need to be               then reinstall the hold-down strap. delimed.  Should deliming   hoses become necessary,  8.   Reinstall wiring to heating element and thermostat.  Reinstall Bloomfield recommends               the hi-limit thermostat (if removed).  For brewers with hot   replacing
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        EXPLODED VIEW & PARTS LIST  CABINET & RELATED COMPONENTS  18