ملخص المحتوى في الصفحة رقم 1 
                    
                        VIDEO OUT 4
VIDEO OUT 3
VIDEO OUT 2
VIDEO OUT 1
VIDEO IN 4 VIDEO OUT 4
VIDEO IN 3 VIDEO OUT 3
VIDEO IN 2 VIDEO OUT 2
VIDEO OUT 1
CPU/KVM SWITCH/VIDEO
OUT
AdderLink X2 Multi Screen
Remote Extenders
LOCAL
MULTISCREEN
www.adder.com
REMOTE
MULTISCREEN
www.adder.com                                                                                                                                                                                                                                      
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        SECT 1 Contents Welcome Special configuration Introduction.................................................................................2 Configuration ............................................................................16 Supplied items .............................................................................3 What are hotkeys? ...........................................................16 Module features ..........................................................................4 
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        SECT 2 Welcome Introduction Thank you for choosing the AdderLink X2 Multi Screen extenders. Comprising separate channels. For both variants, a local module attaches to the computer  two compact modules, these extenders allow you to place multiple video system and provides connections for the local peripherals while the remote  monitors and serial devices together with a keyboard, mouse and audio module is placed up to 200m away and handles the remote peripherals. The  peripherals up to 200 metre
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        VIDEO OUT 2 VIDEO OUT 1 VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 CPU/KVM SWITCH/VIDEO 1 OUT VIDEO OUT 4 VIDEO OUT 3 VIDEO OUT 2 VIDEO OUT 1 VIDEO IN 4 VIDEO OUT 4 VIDEO OUT 3 VIDEO IN 3 VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 CPU/KVM SWITCH/VIDEO OUT Supplied items X2 Multi Screen MS2 LOCAL module REMOTE module Multi-cable for keyboard,  video channel 1, mouse and  audio connections between  computer and LOCAL  module Self adhesive  rubber feet Video cable for channels 2-4 (MS2 model has one video  MS2: Ke
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        VIDEO IN 4 VIDEO OUT 4 VIDEO OUT 3 VIDEO OUT 4 VIDEO IN 3 VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 3 VIDEO OUT 1 VIDEO OUT 2 CPU/KVM SWITCH/VIDEO VIDEO OUT 1 OUT Module features Power supply  connection Connections for serial  Switch bank to  ports 1, 2, 3* and 4*  determine certain  from computer   modes and  functions Connections  to REMOTE  module LOCAL X2 Multi Screen module (MS4 model pictured) Connections  for video inputs  2, 3*, and 4*  Power  from computer and signal  activity  indicators Conne
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        1 2 3 4 O N 2 3 4 1 ON ON SECT 3 Installation and operation Installation LOCAL module switches (continued) The installation of the X2 Multi Screen extenders is straightforward and can best  LOCAL Switch 1 be achieved in most cases by following these stages for each module: OFF: Normal operation. • Stage A  Check or set the configuration switch settings ON: (Before power is applied) Places the LOCAL module into flash upgrade  • Stage B  Mount the module mode so that the internal software can be c
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        1 2 3 4 O N 4 1 2 3 ON ON REMOTE module switches REMOTE module switches (continued) REMOTE Switch 1 Determines configuration of hotkeys in conjunction OFF: Normal operation. with switch 3 ON: (Before power is applied) Places the REMOTE module into flash upgrade  Reserved for  mode so that the internal software can be changed. Please see the ‘Flash  future use OFF: Normal operation upgrade’ section in the ‘Special configuration’ chapter. ON: Flash upgrade REMOTE Switches 2 and 3 Determines config
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Stage B - Mounting a module – desk or rack Installation Advice •  For correct operation, the local and remote units must have ground  The X2 Multi Screen extender modules can be situated on a desk (or floor) or  connections. At the computer end, ensure that the computer or KVM switch  alternatively, for larger installations, mounted within optional rack mount chassis  that the LOCAL module is connected to has a ground connection. At the  units. keyboard/monitor/mouse end, ensure that the REMOTE 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        UT 4 N 3 VIDEO OUT 3 VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 CPU/KVM SWITCH/VIDEO OUT VIDEO OUT 3 IDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 UT 4 CPU/KVM SWITCH/VIDEO N 3 VIDEO OUT 3 OUT VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 CPU/KVM SWITCH/VIDEO OUT Stage C - Connections The naming of the LOCAL and REMOTE modules relate to their proximity to Local keyboard and mouse connections the host computer system. Hence, the LOCAL module connects directly to the The LOCAL module provides extra ports to accommodate a keyboa
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        TO REMOTE 4 SERIAL 4 TO REMOTE 3 SERIAL 3 INDOOR TO REMOTE 2 SERIAL 2 USE ONLY TO REMOTE 1 SERIAL 1 POWER VIDEO IN 4 VIDEO OUT 4 VIDEO IN 3 VIDEO OUT 3 VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 CPU/KVM SWITCH/VIDEO OUT VIDEO IN 4 VIDEO OUT 4 VIDEO IN 3 VIDEO OUT 3 VIDEO IN 2 VIDEO OUT 2 VIDEO OUT 1 CPU/KVM SWITCH/VIDEO OUT Additional video channel inputs Serial cable connections The MS2 model provides a second video channel, and the MS4 model provides a You can transfer multiple serial connections from
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        INDOOR E 2 SERIAL 2 USE ONLY TO REMOTE 1 SERIAL 1 POWER TO REMOTE 4 SERIAL 4 TO REMOTE 3 SERIAL 3 INDOOR TO REMOTE 2 SERIAL 2 USE ONLY TO REMOTE 1 SERIAL 1 POWER Twisted pair link connections Power connection (optional on MS2 model) The links between the LOCAL and REMOTE modules are made using between The MS2 and MS4 LOCAL modules both have power input sockets. However,  one and four twisted pair cables, specified to Category 5 or higher. only the MS4 model has a mandatory requirement for power 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        1 2 3 4 VIDEO OUT 1 ON Connections at the REMOTE module Keyboard and mouse connections 1 Connect the keyboard lead to the  purple mini-DIN socket labelled   on the REMOTE module.  Note: When the REMOTE module is rack mounted, the audio connections  must be made after the module has been fixed in place. Access is required  2 Connect the keyboard lead to the  Connection to the rear and above the rack. Remember to remove the audio connections  green mini-DIN socket labelled  on  from keyboard befor
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        TO LOCAL 4 SERIAL 4 TO LOCAL 3 SERIAL 3 VIDEO OUT 4 INDOOR TO LOCAL 2 SERIAL 2 VIDEO OUT 3 USE ONLY VIDEO OUT 2 TO LOCAL 1 SERIAL 1 POWER VIDEO OUT 1 TO LOCAL 4 SERIAL 4 TO LOCAL 3 SERIAL 3 INDOOR TO LOCAL 2 SERIAL 2 USE ONLY TO LOCAL 1 POWER SERIAL 1 Video outputs Twisted pair link connections You can connect multiple video monitors to the REMOTE module (up to two on The links between the LOCAL and REMOTE modules are made using between  the MS2 model or up to four on the MS4 model). one and fou
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        INDOOR 2 SERIAL 2 USE ONLY TO LOCAL 1 SERIAL 1 POWER Power connection 1 Attach the output connector of the  power supply to the socket of the  REMOTE module, labelled POWER. Power  supply  connection REMOTE 2 Insert the IEC connector of the supplied power lead into the corresponding  socket of the power supply. Connect the other end of the power lead to a  nearby mains socket. IEC power connector 13                       
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        TO LOCAL 4 SERIAL 4 TO LOCAL 3 SERIAL 3 INDOOR TO LOCAL 2 SERIAL 2 USE ONLY TO LOCAL 1 SERIAL 1 POWER Operation General use Power and activity indicators In use, the X2 Multi Screen modules should be almost transparent - the system  On the front panels of all  and its peripherals should operate almost exactly as normal, the only difference  modules are small recessed  being that they are duplicated (see ‘User arbitration’ below) and one set is now  indicators which provide  up to 200 metres away
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Locking and unlocking the system In situations where the computer system (and the LOCAL module) can be  locked away, the X2 Multi Screen modules offer a viable security system to deter  unauthorised use. Once a password has been set, a simple key sequence allows  the system to be quickly and securely detached from its peripherals. Only the  correct password will reconnect the remote and local modules.  To lock the system 1 First set a password. For further details, please refer to the ‘Password 
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        SECT 4 Special configuration Entering, using and exiting configuration mode Configuration You can alter the way that the X2 Multi Screen modules operate to suit your  To enter and use configuration mode: requirements. This is done using the Configuration mode and you can affect the  1 Simultaneously press the currently configured  following settings:  hotkeys (by default,  and ) along with .  •  Password setting – allows you to lock the remote module to prevent     The three keyboard indicators 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Password setting Password override Password protection allows you restrict access to the system only to authorised This mode allows you to override the password that has been set at the REMOTE  personnel. A password first needs to be set and then, using the keyboard module and place it into configuration mode so that a new one may be set. This  attached to the REMOTE module, a simple key sequence allows the system to be feature is particularly useful when passwords have been lost or forgotten. q
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Hot plugging and mouse restoration It is strongly recommended that you switch off the computer system before To restore mouse operation when hot plugging: attempting to connect it via the X2 Multi Screen modules. However, if this is not 1 Carefully connect the modules to the system and its keyboard, mouse,  possible then you need to ‘hot plug’ the modules while power is still applied to monitor, audio and serial device. the system. There is not normally a danger of damage to the system, however,
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Image controls - sharpness and brightness The X2 Multi Screen modules incorporate special controls to compensate for To display a suitable high contrast image losses incurred within long cable links. Using these controls you can adjust the The best way to clearly view the effect of sharpness and brightness adjustments  picture sharpness and brightness to improve your remote picture quality. The is to display a high contrast image, with vertical edges, on the screen.  controls allow you to either