ملخص المحتوى في الصفحة رقم 1 
                    
                        Dell™ PowerEdge™ R805 Systems Hardware Owner's Manual  
About Your System  
Using the System Setup Program  
Installing System Components  
Troubleshooting Your System  
Running the System Diagnostics  
Jumpers and Connectors  
Getting Help  
Glossary  
Notes, Notices, and Cautions 
NOTE: A NOTE indicates important information that helps you make better use of your computer. 
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. 
 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Back to Contents Page     About Your System   Dell™ PowerEdge™ R805 Systems Hardware Owner's Manual     Other Information You May Need     Accessing System Features During Startup     Front-Panel Features and Indicators     Back-Panel Features and Indicators     Power Indicator Codes     NIC Indicator Codes     LCD Status Messages     System Messages     Warning Messages     Diagnostics Messages     Alert Messages     This section describes the physical, firmware, and software interface features
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        the remote access controller (RAC) card. See the BMC User's Guide for more information on setup and use of BMC.   This keystroke enters the SAS Configuration Utility. See your SAS controller User's Guide for more information.   If you have the optional battery-cached SAS RAID controller, this keystroke enters the RAID configuration utility. For more information, see the  documentation for your SAS controller card.   If you have PXE support enabled through the System Se
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Hard-Drive Indicator Codes  The hard-drive carriers have two indicators—the drive-activity indicator and the drive-status indicator. See Figure 1-2. In RAID configurations, the drive-status  indicator lights to indicate the status of the drive. In non-RAID configurations, only the drive-activity indicator lights; the drive-status indicator is off.   Figure 1-2. Hard-Drive Indicators     1 drive-status indicator (green and amber) 2 green drive-activity indicator  Table 1-3 lists the drive indicat
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        7 system identification button 8 system status indicator  9 system status indicator connector 10 LOM4 connector (Gb/10Gb)1  11 LOM3 connector (Gb/10Gb)a 12 LOM2 connector (Gb)  13 LOM1 connector (Gb) 14 2.0-compliant USB connectors (2)  15 video connector 16 serial connector  17 remote access controller (RAC) connector (optional)         Connecting External Devices  When connecting external devices to your system, follow these guidelines:  l  Most devices must be connected to a specific connecto
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                           1 link indicator 2 activity indicator   Table 1-5. NIC Indicator Codes       Indicator Indicator Code  Link and activity indicators are off The NIC is not connected to the network.  Link indicator is green The NIC is connected to a valid link partner on the network.  Activity indicator is amber blinking Network data is being sent or received.   LCD Status Messages   The system's control panel LCD provides status messages to signify when the system is operating correctly or when the system nee
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                         Linear PwrGd Linear voltage regulator(s) has failed. Represents See Getting Help.  status of multiple voltage regulators used in the  video and LOM circuitry.   CPU # VCORE Processor # VCORE voltage regulator has failed. See Getting Help.   CPU VTT PwrGd Processor # VTT voltage has exceeded the See Getting Help.  allowable voltage range   CPU # VDDIO Processor # VDDIO voltage has exceeded the See Getting Help.  allowable voltage range  1.0V PwrGd   CPU # VDDA Processor # VDDA voltage has exceed
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        on a component that resides in the specified slot.  If the problem persists, the riser card or system board is faulty. See Getting  Help.   Unknown Err The system BIOS has determined that there has See Getting Help.  been an error in the system, but is unable to  determine its origin.   PCIE Fatal Err The system BIOS has reported a PCIe fatal error Remove and reseat the PCIe expansion cards. If the problem persists, see  on a component that resides in PCIe configuration Troubleshooting Expansion
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                          System cover has been removed. Information only.   >3 ERRs Chk Log LCD overflow message.  Check the SEL for details on the events.  A maximum of three error messages can display  sequentially on the LCD. The fourth message  displays as the standard overflow message.   SEL Full System Event Log is full of events, and is unable Clear the log by deleting event entries.  to log any more events.    Video Off The video has been turned off by the RAC remote Information only.   user.  (LCD lights with
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Configuration. Please wait... detected and is being processed.  BIOS Update Attempt Failed! Remote BIOS update attempt failed. Retry the BIOS update. If problem persists, see Getting Help.  Caution! NVRAM_CLR jumper is installed NVRAM_CLR jumper is installed. CMOS has Remove NVRAM_CLR jumper. See Figure 6-1 for jumper  on system board. been cleared. location.  CPUs with different cache sizes Microprocessors with different cache sizes are Ensure that all microprocessors have the same cache size a
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        PCIe Training Error: Integrated  The specified PCIe device is faulty or For a SAS controller daughter card, reseat the card in the  improperly installed. dedicated PCIe connector. See Installing a SAS Controller  Daughter Card. If the problem persists, see Getting Help.  PCIe Training Error: Slot n Faulty or improperly installed PCIe card in the Reseat the PCIe card in the specified slot number. See  specified slot. Expansion Cards. If the problem persists, see Getting Help.  Plug & Play Configu
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        drive, a message will warn you that you may lose all data on the hard drive. Warning messages usually interrupt the task and require you to respond by  typing y (yes) or n (no).   NOTE: Warning messages are generated by either the application or the operating system. For more information, see the documentation that  accompanied the operating system or application.  Diagnostics Messages   When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in th
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Back to Contents Page   Dell™ PowerEdge™ R805 Systems Hardware Owner's Manual      Notes, Notices, and Cautions   NOTE: A NOTE indicates important information that helps you make better use of your computer.   NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.   CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.  Information in this document is subject to change without notice.  © 2007-2009 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Back to Contents Page     Running the System Diagnostics   Dell™ PowerEdge™ R805 Systems Hardware Owner's Manual     Using Server Administrator Diagnostics     System Diagnostics Features     When to Use the System Diagnostics     Running the System Diagnostics     System Diagnostics Testing Options     Using the Custom Test Options     If you experience a problem with your system, run the diagnostics before calling for technical assistance. The purpose of the diagnostics is to test your  system
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Click the testing option in the Main Menu window. Table 5-1 provides a brief explanation of testing options.   Table 5-1. System Diagnostics Testing Options        Testing Function  Option  Express Test Performs a quick check of the system. This option runs device tests that do not require user interaction. Use this option to quickly identify the  source of your problem.  Extended Test Performs a more thorough check of the system. This test can take an hour or longer.  Custom Test Tests a partic
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Back to Contents Page     Getting Help   Dell™ PowerEdge™ R805 Systems Hardware Owner's Manual     Contacting Dell      Contacting Dell   For customers in the United States, call 800-WWW-DELL (800-999-3355).    NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product  catalog.  Dell provides several online and telephone-based support and service options. Availability varies by country and product, and s
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Back to Contents Page     Glossary   Dell™ PowerEdge™ R805 Systems Hardware Owner's Manual     This section defines or identifies technical terms, abbreviations, and acronyms used in your system documents.  A — Ampere(s).  AC — Alternating current.  ACPI — Advanced Configuration and Power Interface. A standard interface for enabling the operating system to direct configuration and power  management.  ambient temperature — The temperature of the area or room where the system is located.  ANSI — A
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        DNS — Domain Name System. A method of translating Internet domain names, such as www.dell.com, into IP addresses, such as 143.166.83.200.  DRAM — Dynamic random-access memory. A system's RAM is usually made up entirely of DRAM chips.   DVD — Digital versatile disc.  ECC — Error checking and correction.  EEPROM — Electronically erasable programmable read-only memory.  EMC — Electromagnetic compatibility.  EMI — Electromagnetic interference.  ERA — Embedded remote access. ERA allows you to perform
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        LAN — Local area network. A LAN is usually confined to the same building or a few nearby buildings, with all equipment linked by wiring dedicated specifically  to the LAN.  lb — Pound(s).  LCD — Liquid crystal display.  LED — Light-emitting diode. An electronic device that lights up when a current is passed through it.  LGA—Land grid array. A type of processor socket. Unlike the PGA, the LGA interface has no pins on the chip; instead, the chip has pads that contact pins on  the system board.  Li
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        readme file — A text file, usually shipped with software or hardware, that contains information supplementing or updating the product's documentation.  read-only file — A read-only file is one that you are prohibited from editing or deleting.  ROM — Read-only memory. Your system contains some programs essential to its operation in ROM code. A ROM chip retains its contents even after you turn  off your system. Examples of code in ROM include the program that initiates your system's boot routine a