 Troubleshooting & FAQs 32                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Table of Contents 1. Important ................................................1 1.1 Safety Information ..........................................1 1.2 Safety precautions and maintenance ...6 1.3 Notational Descriptions .............................7 1.4 Disposal of product and packing  material ................................................................8 1.5 AntiMicrobial .....................................................9 2. Setting up the monitor .......................10 2.1 Installa
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        1. Important Shutdown Procedure 1. Important We strongly recommended that you should  shut down the system before you start to clean  The monitor is intended for use with Medical  any single components.  Equipment to display alpha, numerical and  graphical data. The subject equipment Philips  Please follow the steps below. monitor is powered by an external recognized  • Close all application programs AC/DC adapter (IEC/EN60601-1). • Close operating software • Turn off power switch  1.1 Safety In
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        1. Important Guidance and manufacturer’s declaration – electromagnetic emissions – for all EQUIPMENT and  SYTEMS The monitor is intended for use in the electromagnetic environment specified below. The customer or  the user of the monitor should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment – guidance The monitor uses RF energy only for its internal function. Therefore, its  RF emissions Group 1 RF emissions are very low and are not likely to
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        1. Important Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and  SYTEMS: The monitor is intended for use in the electromagnetic environment specified below. The customer or  the user of the monitor should assure that it is used in such an environment. Electromagnetic environment –  Immunity test IEC 60601 test level Compliance level guidance Electrostatic 6 kV contact 6 kV contact Floors should be wood, concrete or  discharge (ESD) ceramic tile. If floors 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        1. Important Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and  SYSTEMS that are not LIFE-SUPPORTING:  The monitor is intended for use in the electromagnetic environment specified below. The customer or  the user of the monitor should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment – guidance Portable and mobile RF communications equipment  should be used no closer to any part of t
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        1. Important Recommended separation distances between portable and mobile RF communications equipment  and the EQUIPMENT or SYSTEM – for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING:  The monitor is intended for use in an electromagnetic environment in which radiated RF disturbances  are controlled. The customer or the user of the monitor can help prevent electromagnetic interference  by maintaining a minimum distance between portable and mobile RF communications equipment  (transmitters) 
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        1. Important • Do not knock or drop the monitor during  1.2 Safety precautions and  operation or transportation. maintenance Maintenance  Warnings • To protect your monitor from possible  • We strongly recommended that you should  damage, do not put excessive pressure  shut down the system before you start to  on the monitor panel. When moving your  clean any single components. monitor, grasp the frame to lift; do not lift  • No modification of this equipment is  the monitor by placing your hand
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        1. Important Important information for Burn-in/Ghost  1.3 Notational Descriptions image The following subsections describe notational  • Always activate a moving screen saver  conventions used in this document.  program when you leave your monitor  unattended. Always activate a periodic  Notes, Cautions and Warnings  screen refresh application if your monitor  Throughout this guide, blocks of text may be  will display unchanging static content.  accompanied by an icon and printed in bold or  Uni
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        1. Important help to conserve natural resources and ensure  1.4 Disposal of product and packing  that it is recycled in a manner that protects  material human health and the environment. For more  information about where you can drop off  Waste Electrical and Electronic Equipment- your waste equipment for recycling, please  WEEE contact your local city office, your household  waste disposal service or the shop where you  purchased the product Taking back/Recycling Information for  Customers Phil
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        1. Important 1.5 AntiMicrobial Do you ever wonder how many germs thrive  on your equipment? Germs have become a growing problem in  hospitals worldwide, as they cause disfiguring  and life-threatening infections. These bacteria are  not only dangerous but also hard to eliminate  and may even become multiresistant against  antibiotics and disinfectants, experts warn. With its AntiMicrobial material, Philips Clinical  review displays are best suitable for your clinical  environment.  Note Alcohol 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        2. Setting up the monitor   Install base stand 2. Setting up the monitor 1. Place  the monitor face down on a smooth  surface. Pay attention not to scratch or  damage the screen. 2.1 Installation   Package contents 2. Hold the monitor base stand with both  hands and firmly insert the base stand into  the base column. 3. Attach the monitor base stand to the base  column then fasten base stand. AC/DC Adapter USB Cable (Y-Type)  Note Use only the AC/DC adapter model:   Philips TPV-15W-05 (5V/3A)  C
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        2. Setting up the monitor   Connecting to your computer Reso lution	notification This monitor is designed for optimal  performance at its native resolution, 1920 ×  1080 @ 60 Hz. 2 3   Ph ysical Function 1 Tilt 3 2 1   Kensington anti-theft lock 2   USB connection 3  A C-DC Adapt er : TPV -15W -05   Input: 100-240VAC, 50-60Hz, 0.5-0.3A  Output: 5VDC/3A.  Note • Please note that the DisplayLink software  Swivel has to be installed in your laptop before  you start to use the monitor. • This displa
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        2. Setting up the monitor   Remove the base 2.2 Remove Base Stand and Base Condition: For VESA standard mounting    Remove the Base Stand applications. Before you start disassembling the monitor  1. Remove the 8 screw covers. base, please follow the instructions below to  avoid any possible damage or injury. 1. Extend the monitor base to its maximum  height. 2. Remove the 4 screws and then remove the  base from the monitor. 2. Place the monitor face down on a soft  and smooth surface to avoid sc
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        2. Setting up the monitor  Note This monitor accepts a 100mm x 100mm VESA- Compliant mounting interface.   (Screw type: M4x10) 100mm 100mm 13                                                                                                                                                                                                                                                                                                                                                                       
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        3. Operating the monitor 3. Operating the monitor 3.1 Introduction This monitor allows you to share the images  between your laptop and the monitor by simply  connecting USB cable to your laptop. 3.2 DisplayLink Graphics Software  Installation In order to use your USB monitor as a  secondary display, DisplayLink Graphic software  is required to be installed in your Windows 3. Click [I Accept], then software start to  system. Moreover, the software allows you to install. easily control your prefe
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        3. Operating the monitor 3.3 How to control the display   Windows 7 system On Windows 7, you can configure a DisplayLink device through the use of Windows Display  Properties (WDP). WDP provides a simple method to attach, rotate, duplicate or extend screens as  well as modify screen resolution. To open WDP: There are several ways to open WDP. 1. Right-click on the desktop. A 2. Select Screen Resolution from the menu. 3. WDP opens. 1. From Start menu  Devices and Printers. B 2. Double-click the 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        3. Operating the monitor To set the display Follow this procedure to set the display. 1. Open Screen Resolution. 2. Set the display options. Refer to the table below for details on each option. Menu Option Sub-menu Option Description Display Use the drop down list to select a display to be  configured. Resolution Use the drop down list and user the slider to choose  a resolution. Orientation (Use Landscape Sets the display to landscape view this function if  Portrait Sets the display to portrait
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        3. Operating the monitor To show the DisplayLink Manager menu: 1. From the taskbar, click the show hidden icons arrow to show all available icons. 2. Click the DisplayLink icon , menu appears with several options as below DisplayLink Manager Check for updates Optimize for Video Fit to TV... Advanced Configuration... 3. Refer to the table below for details on each option: Menu Description DisplayLink Manager Opens the Windows display setting window. Check for updates Connects to the Windows updat
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        3. Operating the monitor   Windows Vista and Windows XP system When the monitor is attached to your laptop with Windows Vista and Windows XP system, a  DisplayLink icon appears in the taskbar. This provides the access to the DisplayLink Manager menu. To use the DisplayLink Manager menu 1. Click the DisplayLink icon  on the taskbar. The menu appears as shown below. 2. Refer to the table below for details on each option. Menu Option Sub-menu Option Description DisplayLink Manager Opens the Windows