ملخص المحتوى في الصفحة رقم 1 
                    
                        ®
48" (121.9 CM) GAS PROSTYLE GRILL COOKTOP 
INSTALLATION INSTRUCTIONS 
INSTRUCTIONS D’INSTALLATION DE LA TABLE DE 
®
CUISSON À GAZ AVEC GRIL PROSTYLE 
DE 48" (121,9 CM) 
Table of Contents/Table des matières
COOKTOP SAFETY........................................................................2 SÉCURITÉ DE LA TABLE DE CUISSON .................................15
INSTALLATION REQUIREMENTS ................................................3 EXIGENCES D'INSTALLATION....................................
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        COOKTOP SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediately  DA
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        In the State of Massachusetts, the following installation instructions apply: ■  Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by  the State of Massachusetts. ■  If using a ball valve, it shall be a T-handle type. ■  A flexible gas connector, when used, must not exceed 3 feet. INSTALLATION REQUIREMENTS ■ To eliminate the risk of burns or fire by reaching over the  heated surface units, cabinet storage space located 
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Product Dimensions Cutout Dimensions 48" (121.9 cm) Cooktop  E B B A A D C D O P R M N E L K J C F I H G A. 15" (38.1 cm) I. Provide 2" (5.1 cm) min. cabinet  clearance to motor for cooling  B. Centerline of appliance  purposes pressure regulator J. Wire cover box C. 46¹³⁄₁₆" (118.9 cm) A. 9³⁄₈" (23.8 cm) K. Appliance pressure regulator D. 3⁵⁄₁₆" (8.4 cm) bottom of B. 13⁷⁄₁₆" (34.1 cm) burner box L. Blower C. Select appropriate duct cutout.  E. ¾" (1.9 cm) M. Drain jar (See ducting installation 
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        ■ Make sure there is a minimum of 18" (45.7 cm) of straight  Option 3 - Venting Between Option 4 - Venting behind  vent between the elbows if more than one elbow is used. Floor Joist Cabinet Kick Plate ■ Elbows too close together can cause excess turbulence that  reduces airflow. ■ Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm) or 3¹⁄₄" x 10"  (8.3 x 25.4 cm) system. ■ Do not reduce to a 5" (12.7 cm) system after using  6" (15.2 cm) or 3¹⁄₄" x 10" (8.3 x 25.4 cm) fittings. ■ Avoid forming han
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 4.5 ft Electrical Requirements to 6" (15.2 cm) transition (1.4 m) IMPORTANT: The cooktop must be electrically grounded in  accordance with local codes and ordinances, or in the absence  of local codes, with the National Electrical Code, ANSI/NFPA 70  or Canadian Electrical Code, CSA C22.1. 6" (15.2 cm) to 3¹⁄₄" x 10" 1 ft (8.3 cm x 25.4 cm) transition (0.3 m) This cooktop is equipped with an electronic ignition system that  will not operate if plugged into an outle
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        ■ Must include a shutoff valve:  Type of Gas The supply line must be equipped with a manual shutoff  valve. This valve should be located in the same room but  external to the cooktop opening, such as an adjacent  Natural Gas: cabinet. It must be accessible without removing the cooktop,  This cooktop is design-certified by CSA International for use with  and it should be in a location that allows ease of opening and  Natural gas or, after proper conversion, for use with LP gas.  closing. Do not b
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        INSTALLATION INSTRUCTIONS b.) Position the cooktop in the countertop cutout. The main  control panel should overlap the top of the lower control  Install Cooktop panel as shown in the following illustration. Decide on the final location for the cooktop. WARNING Excessive Weight Hazard Use two or more people to move and install cooktop. A Failure to do so can result in back or other injury. 1. Open carton as instructed on product packaging. 2. Remove shipping materials and tape from cooktop. 3. R
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Make Gas Connection 4. Install the pressure regulator with the arrow pointing up  toward the bottom of the cooktop base and in a position  WARNING where you can reach the regulator access cap. B A C Explosion Hazard D Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. A. Access cap  B. Rear of cooktop If connected to LP, have a qualified person make sure  C. Gas pressure regulator  gas pressure does not exceed 14" (36 cm) water  
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        To Open To Close Burner Ignition If the “low” flame needs to be adjusted: Check Operation of Surface Burners Push in and turn the surface burners control knobs to light.  1. Light 1 burner and turn to lowest setting. The surface burner flame should light within 4 seconds. The first  2. Remove the control knob. time a surface burner is lighted it may take longer that 4 seconds  3. Hold the knob stem in the low position using a pair of pliers.  to light because of air in the gas line.  Use an ¹⁄₈"
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        On any burner, closing the air shutter too far will cause the flame  to become soft and yellow tipped. Opening the air shutter too  Complete Installation wide will cause the flame to blow away from the burner ports.  1. Check that all parts are now installed. If there is an extra part,  Proper adjustment will produce a sharp, clearly defined, even  go back through the steps to see which step was skipped. blue flame. 2. Check that you have all your tools. A 3. Dispose of/recycle all packaging mat
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        GAS CONVERSIONS IMPORTANT: Gas conversions from Natural gas to LP gas must  be done by a qualified installer. To Convert Gas Pressure Regulator 1. Remove the access cap by using a wrench, turning the  access cap counterclockwise. WARNING 2. Remove spring retainer from the cap by pushing against the  flat side of the spring retainer. Look at the spring retainer to  locate the “NAT” or “LP” position. Turn over the spring  retainer so the “LP” is showing on the bottom. Snap the  spring retainer bac
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        To Convert Surface Burners Natural Gas Conversion 1. Turn manual shutoff valve to the closed position. 1. Remove Natural gas orifice hoods. Locate the LP gas orifice  hoods from the package attached to the outer plenum area of  B this appliance. 2. To convert from Natural gas to LP gas, apply a ½" open-end  A wrench to hex section of orifice hood. Turn counterclockwise  to remove. C 3. Replace with correct color-coded orifice hoods (supplied).  See the “LP Gas Orifice Hood Chart.” Turn clockwise
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Natural Gas Orifice Hood Chart To Convert Surface Burners Burner BTU/hr Orifice Diameter Color (inches) 1. Remove LP gas orifice hoods. Locate the Natural gas orifice  Left rear 8,000 #55 .0520 Green hoods that were originally installed on the cooktop. 2. To convert from LP gas to Natural gas, apply a ½" open-end  Left front 8,000 #55 .0520 Green wrench to hex section of orifice hood. Turn counterclockwise  Center rear 10,000 #53 .0595 Brass to remove. Center front 10,000 #53 .0595 Brass 3. Repl
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        SÉCURITÉ DE LA TABLE DE CUISSON Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de  toujours lire tous les messages de sécurité et de vous y conformer.  Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous  et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte de
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables : ■  Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le  personnel qualifié d’une entreprise licenciée par l’État du Massachusetts. ■  Si une vanne à boisseau sphérique est utilisée, elle doit comporter une manette “T”. ■  Si un conduit de raccordement flexible est utilisé, sa longueur ne doit pas dépasser 3 pi. EXIGENCES D'INSTALLATION
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        IMPORTANT : Afin d’éviter d’endommager les placards,  consulter l’installateur ou le fabricant des placards pour Dimensions du placard déterminer si les matériaux utilisés peuvent subir un changement  de couleur, une déstratification ou d’autres dommages. C Résidence mobile – Spécifications additionnelles à  respecter lors de l’installation L L’installation de cette table de cuisson doit être conforme aux  F C dispositions de la norme Manufactured Home Construction and  B   K A Safety Standard, 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        ■ Éviter les assemblages par sertissage à la main. Les  sertissages à la main peuvent réduire la circulation d’air. Exigences concernant l’évacuation ■ Pour une bonne performance, utiliser une bouche de  IMPORTANT : L'évacuation de cette table de cuisson doit se  ® décharge Jenn-Air . Si une autre bouche de décharge de toit  faire vers l’extérieur. ou murale est utilisée, s’assurer que ses dimensions ne sont  ■ Ne pas terminer le circuit d’évacuation dans un grenier ou  pas plus petites et qu’el
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Option 3 - Évacuation entre Option 4 - Évacuation  les solives au plancher derrière le garde-pieds du 6" (15,2 cm) 0 pi placard (0,0 m) Raccord de 3¹⁄₄" x 10" 4,5 pi (8,3 cm x 25,4 cm) vers (1,4 m) 6" (15,2 cm) Raccord de 6" (15,2 cm) vers 1 pi    3¹⁄₄" x 10" (8,3 x 25,4 cm) 3¹⁄₄" x 10"  (0,3 m) B A (8,3 cm x 25,4 cm) A B A. Bouche de décharge murale A. Bouche de décharge murale Raccord coudé à 90° de 3¹⁄₄" x 5,0 pi B. Conduit de dia. 6" (15,2 cm) B. Conduit de dia. 6" (15,2 cm)  pour sortie à t
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Spécifications électriques Spécifications de l'alimentation en gaz IMPORTANT : La table de cuisson doit être correctement reliée à  la terre en conformité avec les codes et règlements locaux en  AVERTISSEMENT vigueur, ou en l'absence de tels codes, avec le National Electrical  Code, ANSI/NFPA 70 ou le Code canadien des installations  électriques, CSA C22.1. Cette table de cuisson est dotée d'un système d'allumage  électronique qui ne fonctionnera pas en cas de branchement  dans une prise qui n'e