                        IMPORTANT FOR YOUR SAFETY    THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO  INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD  START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS  MANUAL.    POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN  THE EVENT THE SMELL OF GAS IS DETECTED.  THIS INFORMATION CAN BE  OBTAINED FROM THE LOCAL GAS SUPPLIER.        IMPORTANT  IN THE EVENT A GAS ODOR IS DETECTED, SHUT  DOWN UNITS AT MAIN SHUTOFF VALVE AND  CONTACT THE LO
                    
                    Resumen del contenido incluido en la página 3 
                    
                        INSTALLATION, OPERATION AND CARE OF  GAS COUNTERTOP CHARBROILERS    GENERAL    Gas Countertop Charbroilers are designed for commercial use only and feature fast,  efficient gas heat.  Each burner is controlled by an adjustable gas valve. Cast radiants  are located directly above each burner to maintain uniform temperature. Radiants are  easily removed for cleaning when cool.    Heavy-duty, cast iron top grates are reversible to allow all or part of the cooking grid  surface to be level or sloped
                    
                    Resumen del contenido incluido en la página 4 
                    
                        supply connection(s).  Provide 24" clearance at the front for cleaning, maintenance,  service and proper operation.    Minimum clearances to combustible construction are 12" to the back and 9" to the sides.  Minimum clearances to non-combustible walls are 0" to the rear and 0" to the sides.  INSTALLATION CODES AND STANDARDS  The Charbroiler must be installed in accordance with:  In the United States of America:  1. State and local codes.  2. National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest e
                    
                    Resumen del contenido incluido en la página 5 
                    
                            LEVELING  It is important that the charbroiler is level front to back and left to right.  Areas of uneven  heat distribution will occur on an unleveled unit.  The charbroiler is equipped with  adjustable legs.  Turn the feet at the bottom of the legs to adjust to level.  The unit should  be rechecked for level anytime it has been moved.    VENTILATION HOOD  The broiler should be installed under a suitable ventilation hood. For safe operation and  proper ventilation, keep the space between th
                    
                    Resumen del contenido incluido en la página 6 
                    
                            GAS PRESSURE REGULATOR INSTALLATION  Gas regulator pressure is preset at 5” Water Column (W.C.) for natural gas, and 10” W.C.  for propane gas. Minor adjustments may be required based on site specific gas pressure.  Install the regulator as close to the broiler on the gas supply line as possible. Make sure  that the arrow on the underside of the regulator is oriented in the direction of gas flow to  the broiler (Fig. 2) and the regulator is positioned with the vent plug and adjustment  screw
                    
                    Resumen del contenido incluido en la página 7 
                    
                        BURNER VALVES    Fig. 2  All orifices are of the fixed type and require no adjustment.  Standing pilots should be adjusted to provide a slight yellow tip on the flame.  Pilots may be  lighted by removing adjacent cast iron top grates and radiants.    Air shutters on the main burners must be individually adjusted to provide a blue flame.  All traces  of yellow should be adjusted out of the burner flame.  While making adjustments, you may notice  that some burners, especially to the far right and 
                    
                    Resumen del contenido incluido en la página 8 
                    
                        COMPONENT PARTS  The Achiever Charbroiler comes with several  standard parts as illustrated. Each can be  easily removed and installed easily by hand for  cleaning and maintenance. Note that the  Burner and Deflector are an assembly and are  NOT designed to be disassembled.     You will find that the two of the Burner- Deflector assemblies on the extreme right and  left of your charbroiler have Deflectors that are  flat, and not bent as shown. For correct  operation ensure that the flat Burner-D
                    
                    Resumen del contenido incluido en la página 9 
                    
                        ACCESSORIES  STANDS  The charbroiler has an optional 24” high by 30” deep by 24”, 36”, 48”, 60” or 72” wide  stainless steel stand with casters or flanged legs. The front casters lock, and flanged legs  may be bolted to the floor. The stand includes a top shelf with marine edges style lip and  a lower shelf. When mounted on a stand with standard legs and properly leveled, the  cooking surface should be approximately 36” from the floor.  GRATES  The charbroiler has a variety of optional grate acc