Resumen del contenido incluido en la página 1 
                    
                        2012
Room Air Conditioners
AUTO
F
AUTO FAN C
CONTINUOUS AM
PM
88
ON OFF
SET POINT SCHEDULE
ROOM TEMP  
AUTO SPEED CHECK$ FILTER MART
SYSTEM FAN MODE
POWER
FAN SPEED SCHEDULE
Q Chassis Models
115-Volt: SQ05N10*, SQ06N10*, SQ08N10*, SQ10N10*
Cool Only
115-Volt: EQ08N11*
Cool and Electric Heat
  
KuhlQ_Serv/Parts Man (4-12) Last character may vary.
*
93001401_01
Service/Parts Manual                                                                                                                      
                    
                    Resumen del contenido incluido en la página 2 
                    
                        Table Of Contents   Important Safety Information .......................................................................................................................................... 2-4  Introduction ....................................................................................................................................................................... 4  Performance Data ..........................................................................................................
                    
                    Resumen del contenido incluido en la página 3 
                    
                                                  IMPORTANT SAFETY INFORMATION   with the safety procedures required for installation and repair, and who is equipped with the proper tools and  test instruments required to service this product.     shock which can be serious or even fatal. Safety warnings have been placed throughout this manual to alert you to potential hazards that may be  encountered.  If you install or perform service on equipment, it is your responsibility to read and obey these     Your safety and 
                    
                    Resumen del contenido incluido en la página 4 
                    
                         Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel,  and sleeve on the room side of the air conditioning unit while cleaning.   Electrical component malfunction caused by water could result in electric shock or other electrically  unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry.   Never operate the A/C unit with wet hands.     Use on a properly grounded outlet only.  Do not remove groun
                    
                    Resumen del contenido incluido en la página 5 
                    
                        PROPERTY DAMAGE HAZARDS FIRE DAMAGE HAZARDS:  Read the Installation/Operation Manual for this air conditioning unit prior to operating.     Connect to a properly grounded outlet only.  Do not remove ground prong of plug.  Do not cut or modify the power supply cord.  Do not use extension cords with the unit.      WATER DAMAGE HAZARDS:  Improper installation maintenance, or servicing of the air conditioner unit, or not following the above  Safety Warnings can result in water damage to personal ite
                    
                    Resumen del contenido incluido en la página 6 
                    
                        UNIT IDENTIFICATION KuhlQ Model Number Code   S Q 08 N  1  0  A - A   1st Digit – Function    E = Electric Heat    S = Straight Cool  7th Digit – Options  0 = Straight Cool  1 = 1 KW Heat Strip, Nominal  2nd Digit   Q = Chassis Size 6th Digit – Voltage  1 = 115 Volts 5th Digit - Model Series / Year Introduced 3rd and 4th Digit - Approximate        N=2012     Heating BTU/Hr capacity listed in the     Serial Number  A  B A    Y             00001   Decade Manufactured        Production Run Number  
                    
                    Resumen del contenido incluido en la página 7 
                    
                        PERFORMANCE DATA  * R-410A  EVAP. AIR TEMP. DEG. F OPERATING PRESSURES ELECTRICAL RATINGS BREAKER FUSE REF. COOLING CONDENSER  Discharge Temp Suction Temp Super Heat Sub-Cooling Voltage PERFORMANCE DATA** TEMPERATURE DEG. F Temp. Locked Rotor Charge in  Discharge Air Suction Discharge Amps Cool Amps Heat 60 Hertz Amps Drop F. Amps OZ. 57 23 115 146 63 10 13 158 387 9 29.0 17.0 115 15 SQ05N10-A SQ06N10-A 57 23 115 146 63 10 13 150 387 4.9 29.0 17.0 115 15 SQ08N10-A 58 23 118 158 63 12 20 147 415 
                    
                    Resumen del contenido incluido en la página 8 
                    
                        ELECTRICAL DATA WARNING ELECTRIC SHOCK HAZARD  Turn off electric power before service or  installation. All electrical connections and wiring MUST be      the National Electrical Code and all local codes             death. NOTICE FIRE HAZARD              electically unsafe conditions which could cause moderate  or serious property damage. Read, understand and follow the above warning. Wire Size  Use ONLY wiring size recommended for single outlet branch circuit. Fuse/Circuit Breaker Use ONLY the 
                    
                    Resumen del contenido incluido en la página 9 
                    
                        WARNING: Before Operating Your Unit WARNING Make sure the wiring is adequate for your unit. Electrical Shock Hazard If you have fuses, they should be of the time delay type.  Before you install  Make sure your electrical receptacle has the or relocate this unit, be sure that the amperage rating of the circuit breaker  same configuration as your air conditioner’s or time delay fuse does not exceed the amp rating listed in Table 1. plug. If different, consult a Licensed Electrician. Do not use plu
                    
                    Resumen del contenido incluido en la página 10 
                    
                        Kuhl Q Control Panel Operation Let’s check out how to control your air conditioner. On the control panel, just above the POWER , is a liquid crystal display (LCD). All of the control panel function  buttons and mode icons can be viewed in Figure 6. Power On – Press the button to turn on the air conditioner. The power button illuminates to indicate that the power is on. The backlight on the power switch  will automatically dim to 20% intensity after 15 seconds of inactivity. The remote control ca
                    
                    Resumen del contenido incluido en la página 11 
                    
                        Kühl Control Options The  Kühl gives you a variety of options for control, programming, and The “Residential” (40 Hr. Work Week) Schedule has four (4) time periods: 06:00,  scheduling including wireless capabilities 08:00, 18:00, and 22:00.  This option will cause your Kühl Q unit to raise the room  temperature temporarily to 85°F during the hours when most people are away  at work, lower them again to 78°F prior to the time when most people will return  Wireless Programming and Control: home, a
                    
                    Resumen del contenido incluido en la página 12 
                    
                        FAN MODE AUTO FAN FAN MODE – The  button allows you to select between  and  Control Panel Operation Instructions CONTINUOUS  modes. To select, press once and let go. SYSTEM - The SYSTEM button allows you to sequentially select three modes  of operation. To select, press once and let go. COOL MODE   HEAT MODE    Not available on some models F FAN ONLY MODE AUTO FAN COOL MODE SET POINT FRR112 AUTO FAN When in the  mode, the fan operates only when the system has a demand to cool or heat the room. N
                    
                    Resumen del contenido incluido en la página 13 
                    
                        UP  and DOWN  - arrows - Pressing either   or  button changes ºF - ºC Select the system's set point (desired room temperature). These buttons are also  used for setting the Timer and other programming. F AUTO FAN F AUTO FAN SET POINT SET POINT FRR132 To switch from degrees Fahrenheit (F) to Celsius (C), press  and FRR100 buttons simultaneously for three seconds. F AUTO FAN SET POINT FRR101 FRR133 One press equals 1 degree of change. Holding the button down for more  An “F” will  flash for 5 seco
                    
                    Resumen del contenido incluido en la página 14 
                    
                        DIM Function Wait Icon There are three separate display brightness levels, AUTO, 20% and full  (100%). To change the DIM setting, press the Power button for three  seconds. F AUTO FAN SET POINT FRR120 The wait icon  illuminates when the compressor lockout is active. FRR192 Control Panel Lock The 1 indicates a DIM setting of Auto (factory default on new units). Use   FAN TIMER To lock the front panel controls, press and hold the SPEED +  buttons  SCHEDULE the       or        buttons to change the
                    
                    Resumen del contenido incluido en la página 15 
                    
                        TIMER OR SCHEDULE OPTIONS 1 OR 2 SELECTION The control system has one Timer and two Schedule functions: A. Timer (factory default) - Allows you to command the unit to turn  F ON and OFF at a time you program. Setting the start, stop and day  AUTO FAN can be found latter in this manual on page 15. B. Residential Schedule - When selection #1 is selected, the unit  SET POINT follows a pre-programmed set of operational parameters that  covers 7 days of the week with 4 time windows during each day.  
                    
                    Resumen del contenido incluido en la página 16 
                    
                        TIMER SETTINGS 1. Set time and day 2. Set start time F 3. Set stop time Figure 4 AUTO FAN SET POINT FRR131 Press TIMER SET (Refer to Figure 4) button to exit and save the SET  TIME function. The TIMER SET button must be pressed within 15 second.  Button inactivity for more than 15 seconds causes the display to time out  and return to the normal operating display. TIMER HOUR MIN SET FRIEDRICH AIR CONDITIONING CO. SAN ANTONIO, TX Timer Start Time FRR097 SET TIME AND DAY - To adjust the unit's time
                    
                    Resumen del contenido incluido en la página 17 
                    
                        Set theTimer Stop Time Timer ON Scenarios Scenario 1 F AUTO FAN F AUTO FAN SET POINT SET POINT FRR144 The display shows a normal system. Press and hold the MIN button (Figure  FRR156 4) for 3 seconds. Note the Timer start - stop times may be set even when  The display shows a normal operating system. the system is in the Schedule mode. AM OFF FRR145 FRR157 Use the   or  button to adjust the hour. Press the TIMER SET button  If the Timer function is turned ON during the Timer’s OFF time, the     
                    
                    Resumen del contenido incluido en la página 18 
                    
                        Timer OFF Scenarios Scenario 1 Timer - Schedule Control Block F AUTO FAN SET POINT SCHEDULE FRR166 FRR148 The display shows the unit in Timer mode during an in-active (OFF) period. If the unit is operating in the TIMER or SCHEDULE mode, and you press  TIMER any bytton except the                 button, the TIMER        icon begins to SCHEDULE blink. All button action is blocked. F AUTO FAN F AUTO FAN SET POINT SET POINT SCHEDULE FRR167 If the Timer function is turned OFF during an in-active (OFF
                    
                    Resumen del contenido incluido en la página 19 
                    
                        FAN SPEED Button - Used to sequentially select new fan speed, plus  Remote Control Operation FAN AUTO operation. When the  button is pressed, the fan speed icon  SPEED (triangle) changes to indicate the new speed level.  Fan speed automatically  Remote Control - Refer to Figures 10 and 11 during operation description. varies depending on the set temperature on the control panel and the actual  Getting Started - Install two (2) AAA batteries in the battery compartment  room temperature.  For exam
                    
                    Resumen del contenido incluido en la página 20 
                    
                        Figure 10 DISPLAY AUTO FAN CONTINUOUS 88 AUTO  C F SYSTEM FAN MODE SYSTEM FAN MODE POWER POWER TEMPERATURE TEMPERATURE UP DOWN FAN SPEED SCHEDULE SCHEDULE FAN SPEED FRR081 Figure 11 COOL FAN ONLY HEAT ICON ICON ICON SYSTEM MODE AUTO FAN FAN MODE CONTINUOUS 88 FAN AUTO  SPEED C F °F / °C ICONs SCHEDULE ICON FRR082