Industrial 3-Port Fast Ethernet 
Media Converter Switches 
 
KSD-103-A series 
KSD-103-B series 
 
 
Installation Guide 
 
 
 
 
 
 
 
 
 
 
 
 
DOC.081111 
1/20                                                                                                                                                                                                                                                                                                                                             
                    
                    Resumen del contenido incluido en la página 2 
                    
                        (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in  any form or by any means or used to make any directive work (such as translation or transformation)  without permission from KTI Networks Inc.    KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from  time to time without obligation on the part of KTI Networks Inc. to provide notification of such  revision or change.    For more information, contact:
                    
                    Resumen del contenido incluido en la página 3 
                    
                        The information contained in this document is subject to change without prior notice. Copyright (C)  All Rights Reserved.    TRADEMARKS  Ethernet is a registered trademark of Xerox Corp.     FCC NOTICE  This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two  conditions: (1) This device may not cause harmful interference, and (2) this device must accept any  interference received including the interference that may cause.    CE NOTICE  Marking by the sy
                    
                    Resumen del contenido incluido en la página 4 
                    
                        Table of Contents  1.  Introduction ................................................................................................................................5  1.1 Features.................................................................................................................6  1.2 Product Panels ......................................................................................................6  1.3 Specifications...............................................................
                    
                    Resumen del contenido incluido en la página 5 
                    
                        1.  Introduction  The industrial rated KSD-103 Fast Ethernet switch series supports three switching-base segment  communications and benefit the following applications and make fiber deployment easier :   Copper to fiber bridging converter   Multimode fiber to single mode fiber bridging converter   Fiber cable extender   Cascaded fiber networking        Depending on the types of the network ports, two different model series are defined as follows:    Model Copper Port (RJ-45) Fiber Port  KSD-103
                    
                    Resumen del contenido incluido en la página 6 
                    
                         High and wide operating Temperature   Power input interface: Industrial screw terminal block and DC power jack for external  commercial power adapter as option   Screw panel and DIN rail mounting support for industrial enclosure   Industrial-rated Emission and Immunity performance    1.1 Features   Provide 3 switching-base network segments   Auto MDI/MDI-X crossover function on the TP copper port   Support IEEE 802.3x flow control for full-duplex operation   Support Back-pressure flow control f
                    
                    Resumen del contenido incluido en la página 7 
                    
                        KSD-103-B      1.3 Specifications  Copper Ports  Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX  Connectors Shielded RJ-45 jacks  Pin assignments Auto MDI/MDI-X detection  Configuration Auto-negotiation  Transmission rate 10Mbps, 100Mbps  Duplex support Full/Half duplex  Network cable Cat.5 UTP up to 100 meters    Fiber Ports  Connectors ST, SC, VF-45, Bi-Directional SC (model dependent)  Configuration 100Mbps, Full duplex  Network cables MMF 50/125 60/125 μm, SMF 9/125 μm  Eye safety IE
                    
                    Resumen del contenido incluido en la página 8 
                    
                        Forwarding & filtering Non-blocking, full wire speed  Switching technology Store and forward  Maximum packet length 1536 bytes max.  Flow control IEEE 802.3x pause frame base for full duplex operation  Back pressure for half duplex operation  Broadcast Storm Protection design    DC Power Interface  Interface Screw-type terminal block  1. Two pairs for power wire cascading  2. One pair for alarm relay output  DC Jack (-D6.3mm/+D2.0mm)  Operating voltages +7V ~ +50V(+5%)  Power consumption KSD-103
                    
                    Resumen del contenido incluido en la página 9 
                    
                          Certificate  FCC       Part 15 Class B  CE/EMC      EMI EN50081-1 Class B          EMS EN55024  CE/LVD Safety    EN 60950    EN 50081-1/1992 :  EN55022:1994/A1:1995/A2:1997  EN61000-3-2:2000  EN61000-3-3:1995/A1:2001    EN 55024:1998/A1:2001  IEC 61000-4-2:1995 ESD Test  IEC 61000-4-3:1995 RS Test  IEC 61000-4-4:1995 EFT/BURST Test  IEC 61000-4-5:1995 Surge Test  IEC 61000-4-6:1996 CS Test  IEC 61000-4-8:1993 Magnetic Field  IEC 61000-4-11:1994 Voltage Int. Dips  9/20                          
                    
                    Resumen del contenido incluido en la página 10 
                    
                        2.  Installation  2.1 Unpacking  Check that the following components have been included:   Information CD   The device unit   DIN-rail mounting bracket  If any item is found missing or damaged, please contact your local reseller for replacement.    The following are available optional accessories:   Panel Mounting Bracket   The bracket is used for mounting the device on a panel surface.   Commercial-rated AC power adapters:   - Rated input AC120V/60Hz, AC230V/50Hz, AC100V/50-60Hz, AC240V/50Hz  -
                    
                    Resumen del contenido incluido en la página 11 
                    
                        label. If you are not sure of the type of power source required, consult your service provider or  local power company.    2.3 DIN-Rail Mounting  In the product package, a DIN-rail bracket is installed on the device for mounting the device in a  industrial DIN-rail enclosure.     The steps to mount the device onto a DIN rail are:  1. Install the mounting bracket onto the device unit as shown below:    2. Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until
                    
                    Resumen del contenido incluido en la página 12 
                    
                        The final mechanical dimensions after installing DIN rail mounting bracket are:      2.4 Panel Mounting  The product is provided with an optional bracket for panel mounting. The bracket supports mounting  the device on a plane surface securely. The mounting steps are:  1. Install the mounting bracket on the device unit. Screw the bracket on the device unit.    2. Screw the device unit on a panel. Make sure that there are proper heat dissipation from and  adequate ventilation around the device. D
                    
                    Resumen del contenido incluido en la página 13 
                    
                        2.5 Applying Power  The power specifications of the device are:    Operating Voltage +7 ~ +50VDC  Power Consumption 4W max. @+50VDC        Using Terminal Blocks  Either DC1 interface or DC2 interface can be used to receive DC power from an external power  system. Or, DC2 also can be used to deliver the power received on DC1 to next device in cascading  way.  DC1   +Vdc Positive (+) terminal  DC1    -Vdc Negative (-) terminal  DC2   +Vdc Positive (+) terminal  DC2   -Vdc Negative (-) terminal    
                    
                    Resumen del contenido incluido en la página 14 
                    
                          If cascading the power to next device is needed, install the power wires and plug for another switch.  Then, use DC2 contacts.    Note: Only up to four device units can be cascaded to receive power from one main power input  source.    Using DC Power Jack  DC Jack Connector: D 6.3mm  D 2.0mm  AC Power Adapters: Optional power adapters are available for purchasing.    Connect power adapter DC plug to the DC power jack of the converter before connecting to the AC  outlet. Connect the power adapt
                    
                    Resumen del contenido incluido en la página 15 
                    
                          Use the provided 2P terminal plug for signal wiring and plug into the PF+/- contacts.    Relay Output Normal PF+ and PF- contacts shorted  Indication Alarm PF+ and PF- contacts open    Alarm Events:   Input power failure   Specific fiber port link down (To specify the fiber ports, use the DIP SW located on bottom.)      KSD-103-A  SW1 ON Enable broadcast storm protection  OFF Disable broadcast storm protection  SW2 ON Enable FX port link down alarm  OFF Disable FX port link alarm  KSD-103-B  S
                    
                    Resumen del contenido incluido en la página 16 
                    
                        3.  Making LAN Connections  3.1 Making Copper Port (RJ-45) Connections  The copper ports support the following connection types and distances:    Network Cables  10BASE-T:  2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm  100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm  Link distance: Up to 100 meters    Auto MDI/MDI-X Function  This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid  MDI to MDI-X connection with the remote connected devi
                    
                    Resumen del contenido incluido en la página 17 
                    
                        3.3 LED Indication  KSD-103-A    KSD-103-B      LED     Function      State   Interpretation       PWR     Power status     ON   The power is supplied to the device.                OFF   The power is not supplied to the device.  UTPx     Copper port link status ON   Port link is established. (No traffic)                BLINK  Port link is up and there is traffic.                OFF   Port link is down.       FXx     Fiber port link status  ON   Port link is established. (No traffic)             
                    
                    Resumen del contenido incluido en la página 18 
                    
                        4.  Applications  4.1 Application in Industrial Networks  The following figure illustrates an application example in an industrial network. Four devices are  cascaded by fiber cables.      4.2 Copper to Fiber Bridging Media Converter Application      4.3 Bridging Multimode to Single Mode Fiber Converter Application    18/20                                                                                                                                                                               
                    
                    Resumen del contenido incluido en la página 19 
                    
                        5.  Appendix  5.1 Model Definition  KSD-103-A  Model Ext. FX Connector Cable Ref. Distance Operating Temperature  o -T Duplex ST MMF 2km -10 ~ 70 C  o -C Duplex SC MMF 2km -10 ~ 70 C  o -C1 Duplex SC MMF 2km -20 ~ 70 C  o -SA2 Duplex SC SMF 20km -20 ~ 70 C  o -SL2 Duplex SC SMF 20km -20 ~ 70 C  o -SL3 Duplex SC SMF 30km -20 ~ 70 C  o -SL4 Duplex SC SMF 40km -20 ~ 70 C  o -SL6 Duplex SC SMF 60km -20 ~ 70 C  o -W3515 BiDi SC SMF 15 ~ 20km -20 ~ 70 C  o -W5315 BiDi SC SMF 15 ~ 20km -20 ~ 70 C    KS
                    
                    Resumen del contenido incluido en la página 20 
                    
                        5.2 Optical Specifications  KSD-103-A  Model Ext. FX Port Wavelength TX Power Sensitivity RX Max. Power -T FX 1310nm -19 ~ -14dBm -31dBm -14dBm  -C FX 1310nm -19 ~ -14dBm -31dBm -14dBm  -C1 FX 1310nm -20 ~ -14dBm -31dBm 0dBm  -SA2 FX 1310nm -15 ~ -8dBm -31dBm -7dBm  -SL2 FX 1310nm -15 ~ -8dBm -30dBm 0dBm  -SL3 FX 1310nm -15 ~ -8dBm -34dBm 0dBm  -SL4 FX 1310nm -5 ~ 0dBm -34dBm 0dBm  -SL6 FX 1310nm -5 ~ 0dBm -35dBm 0dBm  -W3515 FX 1310nm -14 ~ -8dBm -31dBm 0dBm  -W5315 FX 1550nm -14 ~ -8dBm -31dBm