                        Electric Dryer Installation Instructions
Table of Contents 
DRYER SAFETY ......................................................................... 2
InSTAllATIon REquIREmEnTS ............................................. 3
Tools and Parts ...................................................................... 3
location Requirements ......................................................... 4
Electrical Requirements ........................................................ 6
Install leveling legs .
                    
                    Resumen del contenido incluido en la página 2 
                    
                        DRYER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety  messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediately  DANG
                    
                    Resumen del contenido incluido en la página 3 
                    
                        INSTALLATION REQUIREMENTS ToolS AnD PARTS Gather the required tools and parts before starting installation. Tools needed: Parts supplied (all models):  Flat-blade screwdriver #2 Phillips screwdriver Leveling legs (4) Parts supplied (steam models):  Wire stripper (direct wire Tin snips (new vent  installations) installations) “Y” connector Short inlet hose 1/4" nut driver Vent clamps (recommended) Long inlet hose Rubber washer Parts package is located in dryer drum. Check that all parts   are inc
                    
                    Resumen del contenido incluido en la página 4 
                    
                        DRYER DImEnSIonS LOCATION REQUIREMENTS Front view: 27" (686 mm) 3 35 /8" (899 mm) You will need: 1" ■ A location allowing for proper exhaust installation. See   (25 mm) “Venting Requirements.” ■ A separate 30 amp circuit. Side view:  ■ If using power supply cord, a grounded electrical outlet     located within 2 ft. (610 mm) of either side of dryer. See    29" “Electrical Requirements.” (736 mm) ■ Floor must support dryer weight of 200 lbs. (90.7 kg). Also  consider weight of companion appliance
                    
                    Resumen del contenido incluido en la página 5 
                    
                        Door open view: ■ Additional spacing should be considered on all sides of the  dryer to reduce noise transfer. 1 48 /8" (1238 mm) ■ For closet installation, with a door, minimum ventilation  1 47 /8" openings in the top and bottom of the door are required.  (1197 mm) Louvered doors with equivalent ventilitation openings are  acceptable. ■ Companion appliance spacing should also be considered. Closet installation (dryer only): 3" 34" recommended (76 mm) 2 (864 mm) 48 in. 2 (310 cm ) 18" min. (457
                    
                    Resumen del contenido incluido en la página 6 
                    
                        Closet Installation (stacked washer and dryer): ELECTRICAL REQUIREMENTS 6" It is your responsibility: (152 mm) ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in  conformance with the National Electrical Code, ANSI/NFPA  3" 70 - latest edition and all local codes and ordinances.  (76 mm)   2 48 in. The National Electrical Code requires a 4-wire power supply  2 76" (310 cm ) connection for homes built after 1996, dryer circuits involved  
                    
                    Resumen del contenido incluido en la página 7 
                    
                        If your outlet looks like this: INSTALL LEvELINg LEgS Then choose a 4-wire power supply cord with  ring or spade terminals and UL listed strain  WARNING relief. The 4-wire power supply cord, at least   4 ft. (1.22 m) long, must have 4 10-gauge solid  Excessive Weight Hazard copper wires and match a 4-wire receptacle of  NEMA Type 14-30 R. The ground wire (ground  Use two or more people to move and install dryer. 4-wire  conductor) may be either green or bare. The  receptacle  Failure to do so ca
                    
                    Resumen del contenido incluido en la página 8 
                    
                        ELECTRICAL CONNECTION 2. Remove terminal block cover Power Supply Cord Before you start, disconnect power. Remove hold-down screw  and terminal block cover. POER w SUPPLY  CORD CONNECTION Power supply cord strain relief: Electrical Connection options 1. Attach power supply cord strain relief 1. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to Power Supply Cord Connection. A B Power supply cord 3-wire receptacle C (NEMA Type 10-30R): D Go to Power Su
                    
                    Resumen del contenido incluido en la página 9 
                    
                        2. Attach power supply cord  1. Prepare to connect neutral ground  to strain relief wire and neutral wire. E B A Put power supply cord through the strain relief. Be sure that Remove center terminal block screw (B). Remove neutral  the wire insulation on the power supply cord is inside the ground wire (E) from external ground conductor screw (A). strain relief. The strain relief should have a tight fit with the  dryer cabinet and be in a horizontal position. Do not further  tighten strain relief 
                    
                    Resumen del contenido incluido en la página 10 
                    
                        4. Connect remaining wires 2. Connect neutral wire B C Connect neutral wire (white or center) (C) of power supply cord   Connect remaining wires to outer terminal block screws.  to center terminal block screw (B). Tighten screw. Tighten screws. Finally, reinsert tab of terminal block cover  into slot of dryer rear panel. Secure cover with hold-down  screw. Now, go to “Venting Requirements”. 3. Connect remaining wires 3-wIRE POER w SUPPLY CORD  CONNECTION use where local codes permit connecting  
                    
                    Resumen del contenido incluido en la página 11 
                    
                               5" (127 mm) DIRECT wIRE CONNECTION 4-wIRE DIRECT wIRE  CONNECTION Direct wire strain relief ImPoRTAnT: A 4-wire connection is required for mobile homes  and where local codes do not permit 3-wire connections.  1. Attach direct wire strain relief 1. Prepare your 4-wire cable for   direct connection A B C Unscrew the removable conduit connector (A) and any   screws from a 3/4" (19 mm) UL listed strain relief (UL marking  Direct wire cable must have 5 ft. (1.52 m) of extra length so  on stra
                    
                    Resumen del contenido incluido en la página 12 
                    
                            3½" (89 mm) 3-wIRE DIRECT wIRE  4. Connect neutral ground wire and   CONNECTION neutral wire Use where local codes permit connecting   cabinet-ground conductor to neutral wire.  B 1. Prepare your 3-wire cable for   E direct connection C Connect neutral ground wire (E) and place hooked end (hook   facing right) of neutral wire (white or center wire) (C) of direct  wire cable under center screw of terminal block (B). Squeeze  hooked ends together and tighten screw. Direct wire cable must have 
                    
                    Resumen del contenido incluido en la página 13 
                    
                        2. Connect neutral ground wire and   4. Connect neutral wire neutral wire B B C E C Place hooked end of neutral wire (white or center) (C) of direct  wire cable under center terminal block screw (B). Squeeze  hooked end together. Tighten screw. Connect neutral ground wire (E) and neutral wire (white or  center wire) (C) of power supply cord or cable under center  terminal block screw (B). Tighten screw. 5. Connect remaining wires 3. Connect remaining wires Place hooked ends of remaining direct w
                    
                    Resumen del contenido incluido en la página 14 
                    
                        Exhaust hoods: vENTINg ■ Must be at least 12" (305 mm) from ground or any object that  VEnTInG REquIREmEnTS may obstruct exhaust (such as flowers, rocks, bushes, or  snow). Recommended Styles: Louvered Hood Box Hood Acceptable Style: WARnInG: To reduce the risk of fire, this dryer MUST BE  EXHAUSTED OUTDOORS. Angled Hood ImPoRTAnT: Observe all governing codes and ordinances. Elbows: Dryer exhaust must not be connected into any gas vent,  chimney, wall, ceiling, attic, crawlspace, or a concealed 
                    
                    Resumen del contenido incluido en la página 15 
                    
                        optional exhaust installations: PLAN vENT SYSTEM Recommended exhaust installations WARNING Typical installations vent the dryer from the rear of the dryer.  Other installations are possible. Fire Hazard use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death  or fire. Alternate installations for close clearances If you prefer, dryer may be converted to exhaust out right side,  Venting systems come in many varieties
                    
                    Resumen del contenido incluido en la página 16 
                    
                        Determine vent path: INSTALL vENT SYSTEM ■ Select route that will provide straightest and most direct   path outdoors. 1. Install exhaust hood ■ Plan installation to use fewest number of elbows and turns. ■ When using elbows or making turns, allow as much room   12" min. as possible. (305 mm) ■ Bend vent gradually to avoid kinking. ■ Use as few 90° turns as possible. Determine vent length and elbows needed for best  drying performance: 12" min. ■ Use following Vent System Chart to determine type
                    
                    Resumen del contenido incluido en la página 17 
                    
                        CONNECT INLET HOSES Attach long hose to “Y”   4.  For non-steam models, skip to “Connect Vent” on page 18.    connector and tighten couplings The dryer must be connected to the cold water faucet using   the new inlet hoses. Do not use old hoses.      Turn cold water off, remove and  1.  replace rubber washer One end of the long hose has a wire mesh strainer inside the   coupling. Attach this end to the “Y” connector. Attach washer  cold inlet hose to other side of “Y” connector. Screw on  coupli
                    
                    Resumen del contenido incluido en la página 18 
                    
                        Turn on cold water faucet 6.   2. move dryer to final location Check that the water faucets are turned on. Move dryer to final location. Avoid crushing or kinking vent.  7. Check for leaks After dryer is in place, remove cardboard from under dryer. LEEL v DRYER  1. level Dryer Place  level here Check for leaks around “Y” connector, faucets, and hoses. CONNECT vENT 1. Connect vent to exhaust outlet Check levelness of dryer from side to side. Repeat from   front to back.  noTE: The dryer must be l
                    
                    Resumen del contenido incluido en la página 19 
                    
                         Select a Time Dry heated cycle, and start dryer. Do not select   q 2. Adjust leveling legs  Air Only Temperature setting.       If dryer will not start, check the following: 	 •	Contr ols	ar e	set	in	a	running	or	“On”	position. 	 •	Start	button	has	been	pushed	firmly . 	 •	Dryer	is	plugged	into	an	outlet	and/or	electrical		 	   supply. 	 •	Household	fuse	is	intact	and	tight,	or	cir cuit	br eaker		    has not tripped. 	 •	Dryer	door	is	closed. This dryer automatically runs an installation diagno
                    
                    Resumen del contenido incluido en la página 20 
                    
                        W10240579C W10240583C-SP © 2010 08/10 All rights reserved Printed in U.S.A. 20