Resumen del contenido incluido en la página 1 
                    
                        FOR MEASURABLE SUCCESS
BED  SCALE  7711
Operating Manual
Medicine, health and wellness
www.soehnle-professional.com                                                                                                                                                                                                                                                                                                                                                                                                 
                    
                    Resumen del contenido incluido en la página 2 
                    
                        ENGLISH Bed scale 7711 CONTENTS 1.	 General	information		 p	3 	 Inputs	in	Setting	mode	 p	15 	 Intended	use		 p	3	 	 Settings	in	Setting	mode	 p	15 	 CE	sign		 p	3 	 Settings	in	"Program	Settings"	menu	 p	15	 	 Classification	 p	3 	 Settings	in	"Terminal"	menu		 p	15 	 Safety	instructions		 p	4 	 Use	of	additional	devices		 p	4 5.	 Functions		 p	17 	 Applicator		 p	4 	 Power-on	zeroing		 p	17 	 Operating	concept		 p	4 	 Manual	zeroing		 p	17 	 Maintenance	and	service		 p	4 	 x10	(times	10)	displ
                    
                    Resumen del contenido incluido en la página 3 
                    
                        1. ALLGEMEINE INFORMATIONEN Thank	 you	 for	 choosing	 this	 Soehnle	 Professional	 pro- Soehnle	Professional	will	only	assume	responsibility	 duct.	 All	 the	 features	 of	 this	 product	 were	 designed	to	 for	the	safety	of	the	appliance	if	these	instructions	 the	 state	 of	 the	 art	 and	 are	 optimised	 for	 simple	 and	 are	observed	and	the	appliance	is	operated	in	com- straightforward	 use.	 If	 you	 have	 any	 queries	 or	 exper- pliance	 with	 the	 operating	 instructions.	 The	 applian
                    
                    Resumen del contenido incluido en la página 4 
                    
                        ENGLISH Bed scale 7711 ■	 Safety	instructions ■	 Applicator Before	putting	the	appliance	into	use,	 The	scale	does	not	have	an	applicator.	No	part	is	in- please	read	with	care	the	information	given	in	the tended 	 	for	direct	contact	with	the	patient.	Leakage	 Operating	Instructions.	They	contain	important	in- currents	were	measured	on	the	weighing	devices	in	 structions	for	installation,	intended	use	and	maintec -ompliance	with	classification	of	Type	B	applicators. nance	of	the	appliance.	The	m
                    
                    Resumen del contenido incluido en la página 5 
                    
                        ■	 Disposal sunlight	may	have	an	effect	on	the	accuracy	of	the	 According	to	the	present	state	of	the	ar sc t	 ale.	 The	 scale	 is	 protected	 to	 IP	 54	 protection	 class.	 the	 appliance	 contains	 no	 special	 environ- Therefore,	avoid	high	levels	of	humidity,	vapours,	 mentally	 harmful	 substances.	 This	 product	 aggressive	liquid	media	and	strong	contamination. is	not	to	be	treated	as	regular	hold hous 	e	 waste,	 but	 should	 be	 handed	 in	 to	 an	 electrical/elec- tronic	equipment	re
                    
                    Resumen del contenido incluido en la página 6 
                    
                        ENGLISH Bed scale 7711 unit	functioning	shall	be	rendered	null	and	void.	If	 Soehnle	 Professional	 provides	 an	 individual	 warranty,	 this	means	that	the	appliance	supplied	will	be	free	 from	faults	for	the	duration	of	the	warranty	period.	 Always	 keep	 the	 original	 packaging	 in	 case	 you	 have	 to	return	the	scale. Soehnle	Professional	GmbH	&	Co.	KG Manfred-von-Ardenne-Allee	 12	 ·	 DE-71522	 Backnang Phone	+49	(0)	 	 791 1	/	34	53-0	·	Fax	-211 www.soehnle-professional.com 6            
                    
                    Resumen del contenido incluido en la página 7 
                    
                        2. PUTTING INTO OPERATION ■	 Installing	the	scale	elements The	indicator's	placement	must	allow	for	a	simple	 disconnection	from	the	power	supply. Insert	rechargeable	batteries	in	all	four	weighing	 devices.	When	the	batteries	are	fitted,	the	weighing	 devices	start	to	send	and	attempt	to	set	up	a	radio	 link	to	the	digital	indicator. 1 2 3 Caution	(Fig	1–4	right): Before	switching	on	the	scale,	place	the	weighing	 devices	under	the	four	wheels	of	the	hospital	bed.	 Push	the	weighing	devices	as	
                    
                    Resumen del contenido incluido en la página 8 
                    
                        ENGLISH Bed scale 7711 ■	 Radio	link ■	 Charging	the	batteries Open	the	cover	of	 the	 battery	 charger.	 The	charger	has	 four	compartments	 to	 recharge	 the	 four	 The	Bluetooth	radio	link	operates	over	a	max.	radius	 batteries	 simultane- of	 5m	 if	 there	 is	 no	 partition	 wall	 between	 the	 weig- ously.	 The	 four	 LEDs	 hing	 devices	 and	 the	 digital	 indicator.	 After	 short	 inter- indicate	the	charge	state	for	each	battery.	The	fifth	 ruptions	(e.g.	to	replace	a	battery	or	caused	
                    
                    Resumen del contenido incluido en la página 9 
                    
                        Display	of	link	state: Recommendation: Press	Info	key	+	1.	The	following	appears	in	the	 A	 lways	remove	the	batteries	from	the	weighing	de- indicator	display: vices	after	you	switch	off	the	digital	indicator	and	 place	them	in	the	battery	box	of	in	the	charger.	 Weighing	device	 State	 Battery	voltage This	makes	sure	that	the	scale	works	reliably	the	 1:	0080025005BB7	 OK	 6.3	V next	time	it	is	switched	on. 2:	0080025005C0D	 Error 3:	0080025005C70	 OK	 6.3	V If	the	bed	scale	remains	without	use
                    
                    Resumen del contenido incluido en la página 10 
                    
                        ENGLISH Bed scale 7711 3. INPUT AND CONTROL ■	 Keypad	for	input	and	control KEYPAD:	To	enter	nume- rical	values	or	alphabetic	 ORG	key:	Calls	up	 INFO	 key:	 e.g.	 electro- characters	(alphanumeric	 Organisation	Data nic	nameplate	contai- keypad) ning	reference	data 0	(zero)	key: Press	several	 times	to	display	+	 (plus),	–	(minus)	 and	the	blank	 character F	key:	function	key 		/	 C	key:	 cursor	up	/	 Deletes	the		 cursor	left ENTER	key/ last	numeral		 confirmation	key or	character TARE	key	/	 
                    
                    Resumen del contenido incluido en la página 11 
                    
                        ■	 Alphanumeric	input racter	pressed	is	accepted	and	the	cursor	moves		 It	is	possible	to	make	alphanumeric	inputs	with	the on	 	to	the	next	position.	 combined	numeric	and	alphabetic	character	keypad.Numerical	inputs	can	be	made	in	direct	succession	 without	any	waiting	period,	as	long	as	the	same	 Types	of	input	box number	key	is	not	pressed	several	times	in	successi- •	 Display	fields,	read	only on.	A	cursor	flashes	under	the	last	item	entered. •		 Display/writing	fields	with	numeric	input	op
                    
                    Resumen del contenido incluido en la página 12 
                    
                        ENGLISH Bed scale 7711 ■	 Indicator	display ■	 Icons/characters The	 display	 shows	 a	 number	 of	 different	 views	 de- Icons	in	the	icon	bar pending	 on	 the	 situation.	 It	 is	 divided	 into	 display	 panes. Alibi	memory	capacity	100% Additional	display Icon	bar Alibi	memory	capacity	80% Alibi	memory	capacity	empty Display	panel Keylock Additional	display It	 displays	 BMI,	 Gross,	 Net,	 etc.	 If	 required,	 it	 can	 be	 Multirange/Multidivision	1 switched	 on	 with	 the	 F	 key	 according
                    
                    Resumen del contenido incluido en la página 13 
                    
                        4. SETTING MODE ■	 Keypad	in	Setting	mode ORG	key	 :	 KEYPAD Exits	the	Setting	 mode F	key:	Moves	the	marking 	 	 arrow	up	the	list	or	moves	 C	key:	 the	cursor	to	the	left PRINT/ENTER	key:	 Clears	the	 Calls	up	the	marked	 last	numeral/	 T	key	(TARE	key):	 menu	option	or	saves	 character Moves	the	marking	arrow	 an	input	or	change down	the	list	or	moves	the	 cursor	to	the	right ZEROING	key:	Returns	 ON/OFF	key to	the	next	higher	level	 (back	without	saving		 the	change) 13                      
                    
                    Resumen del contenido incluido en la página 14 
                    
                        ENGLISH Bed scale 7711 ■	 Overview	of	menu	navigation The	following	setting	options	are	available: Hold	mode	 (p	20) Fixed	tare	value	 (p	17) General Clear	fixed	tare	value	 (p	19) Auto	standby	time Program	settings Plausibility	check	sensor	 (p	23/Error	12) Provisional	tare	 (p	19) Dialysis	function	 (p	19) Weighing	+	taring F	key	 (p	22) Hold	mode	 (p	20)	 Second	unit		 (p	14) Version	 (p	14) BMI	function	 (p	20) Terminal Display		 (p	14) Keypad	 (p	14) Calibrated	counter	status* Date/Time	 (p
                    
                    Resumen del contenido incluido en la página 15 
                    
                        ■	 Calling	up	Setting	mode ■	 Settings	in	"Terminal"	menu Switch	the	appliance	on.	After	the	 In	"Terminal"	Setting	mode,	you	will	find	the	follow- power-on	 routine,	 the	 appliance	 starts	 ing	request	and	setting	options. the	 last	 activated	 application	 program	 automatically.	To	call	 Version up	Setting	mode	first	 AZG	software	version		 Display	only press	ENTER	and	then	the	F	key		 + AZG	applications	software		 Display	only simultaneously.	You	are	now	in		 AZG	serial	number		 	 Display	o
                    
                    Resumen del contenido incluido en la página 16 
                    
                        ENGLISH Bed scale 7711 To	accept,	press	ENTER	for	 mode	is	only	accessible	by	 3	seconds. password.	 If	 you	 forget	 your	 Keytone			 Select	"off"	or	"on".	Confir- password,	type	in	the	word	 mation	tone	when	a	key	is	 CLEAR	to	release	access. pressed.	 Factory	 setting:	 "off" Clear		 Clears	the	password	and	 Validation	tone	 Select	"off"	or	"on"	Valida- releases	access tion	tone	when	a	function	 is	 executed.	 factory	 setting:	 Reset	terminal "off" Do	not	execute/	 "Execute"	clears	all Execu
                    
                    Resumen del contenido incluido en la página 17 
                    
                        5. FUNCTIONS ■	 Power-on	zeroing ■	 Weighing	and	taring During	the	power-on	procedure,	the	weight	valuesDisp 	 lay	view sent	by	the	weighing	devices	are	zeroed	until	they	 are	less	than	50%	of	the	max.	weighing	range.	This	 tares	the	empty	bed	and	the	weight	display	goes		 to	zero. ■	 Manual	zeroing Manual	zeroing	corrects	minor	devia-■	 Weighing	with	measured	tare tions	 from	 zero,	 e.g.	 caused	 by	 soiling	 Determine	 and	 tare	 a	 bed	 weight	 without	 patient. on	the	scale.	The	following	c
                    
                    Resumen del contenido incluido en la página 18 
                    
                        ENGLISH Bed scale 7711 ■	 Weighing	with	manually	 Entering	tare	weights	into	the	fixed	tare	 	 entered	tare value	memory If	the	patient	is	already	on	the	bed	and	the		 •		Call	up	the	input	menu bed	weight	is	known,	then	this	can	be	tared	by	 (Setting	mode	>	Program	Settings	>	General	 manual	input.	 >	Fixed	tare	values) Enter	the	known	bed	weight	(tare	weight)	using	•		 Press	ENTER	and	F	key	simultaneously	to	access	 the	KEYPAD.	The	input	appears	in	the	display	with	 Setting	mode. the	current	we
                    
                    Resumen del contenido incluido en la página 19 
                    
                        Transferring	fixed	tare	values	from	a	PC	to	the	•	 If	you	want	to	change	other	tare	memories,	 digital	indicator press	the	F	key	of	the	TARE	key	to	select	the	 •		 Here	you	require	a	special	software.	For	more	 next	 memory	 location	 to	 be	 changed	 and	 repeat	 information,	please	contact	the	Soehnle	Profes- the	procedure	as	described	above. sional	Service	personnel. •	 To	return	to	weighing	mode,	press	the	ZEROING	 key	and	then	the	ORG	key. Changing	 or	 overwriting	 a	 fixed	 tare	 value	 m
                    
                    Resumen del contenido incluido en la página 20 
                    
                        ENGLISH Bed scale 7711 •		 Confir	 m the	 message	 "General"	 by	 pressing	 ENTER. •		 Exit	Setting	mode	by	pressing	the	ORG	key.	The	 •	 Press	the	TARE	key	to	browse	to	"Fixed	tare	va-gross	value	is	displayed. lues"	and	accept	by	pressing	ENTER. 	 Using	the	dialysis	function 	 Clearing	a	tare	value •	 Press	the	F	key	(with	a	load	on	the	scale).	Mes- •	 The	last	selected	fixed	tare	value	memory	is		 sage:	"Place	tare".	Place	the	additional	tare	on	 displayed.	Press	the	F	or	TARE	key	to	browse	 t