Resumen del contenido incluido en la página 1 
                    
                         
 
 
 
 
 
 
 
 
 
ふ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
MS-70 
 
MX-50 
 
MF-50 
 
ML-50 
 
 
 
 
 
 
 
 
 
 
 
WM+PD4000477D 
                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    Resumen del contenido incluido en la página 2 
                    
                        1. 1. This manual and This manual and Mark Marks s   1. 1. This manual and This manual and Mark Marks s       All safety messages are identified by the following, “WARNING” or “CAUTION”, of  ANSI Z535.4 (American National Standard Institute: Product Safety Signs and  Labels). The meanings are as follows:    A potentially hazardous situation which, if not avoided, could  WARNING  result in death or serious injury.  A potentially hazardous situation which, if not avoided, may result  CAUTION  in m
                    
                    Resumen del contenido incluido en la página 3 
                    
                          Contents Contents Contents Contents       1. Safety and Compliance..................................................................3  2. Precautions...................................................................................5  2.1. Installing the Analyzer ..................................................................... 5  2.2. During Use ...................................................................................... 6  2.3. After Use and Maintaining the Analyzer ...........
                    
                    Resumen del contenido incluido en la página 4 
                    
                        8. Check Function...........................................................................41  8.1. Self-Check Function....................................................................... 41  8.1.1. Operation.............................................................................................. 41  8.2. Test Sample (Sodium Tartrate Dihydrate) ....................................... 42  9. Connecting to a Printer ...............................................................43  9.1. P
                    
                    Resumen del contenido incluido en la página 5 
                    
                          2. 2. Safety a Safety an nd Com d Compliance pliance   2. 2. Safety Safety a an nd Com d Comp pliance liance     WARNING    Do not use a sample that could make a dangerous chemical reaction and cause an  explosion or poisonous gas, when the sample is dried.    Keep flammables away from the analyzer.    Parts of the analyzer become very hot. Materials placed near it might catch fire.    Do not use the analyzer in ambient ignitable gas. It may cause explosion and fire.    Use a power source (vol
                    
                    Resumen del contenido incluido en la página 6 
                    
                        C C C Co o o ompli mpli mpli mpliance ance ance ance wit wit wit with h h h F F F FC C C CC R C R C R C Ru u u ule le le les s s s       Please note that this device generates, uses and can radiate radio frequency energy.  This device has been tested and has been found to comply with the limits of a Class  A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are  designed to provide reasonable protection against interference when this device is  operated in a commercial 
                    
                    Resumen del contenido incluido en la página 7 
                    
                          3. 3. 3. 3. Pr Pr Pr Prec ec ec ecautions autions a autions utions       3. 3. 3. 3.1 1 1 1.... IIIIn n n ns s s st t t tall all all alliiiin n n ng g g g the Ana the Ana the Ana the Anallllyz yz yz yzer er er er       --- --- --- ---C C C Ca a a auti uti uti utio o o on for M n for M n for M n for Mea ea ea easure sure sure surement me me ment Saf nt Saf nt Safety  Safety e et ty y   --- --- --- ---       Do not install the analyzer in a dangerous place.    Maintain the following ambient cond
                    
                    Resumen del contenido incluido en la página 8 
                    
                          3. 3.2 2.. Du Dur riin ng g Use Use   3. 3.2 2.. Du Dur riin ng g Use Use     --- --- --- ---C C C Ca a a auti uti uti utio o o on for M n for M n for M n for Mea ea ea easure sure sure sureme me me ment Sa nt Sa nt nt Sa Safety fety --- fety fety --- --- ---     Grip of heater    Operate the analyzer using the following procedure.  cover   Put the sample pan in the correct position.  Grip of pan    Handle the grip of the heater cover to open and  handle close it.    Use the pan handle to move
                    
                    Resumen del contenido incluido en la página 9 
                    
                        
                    
                    Resumen del contenido incluido en la página 10 
                    
                          4. 4. Outline and Outline and Fe Features atures   4. 4. Outl Outline and ine and  Fe Featu atur re es s       The moisture analyzer is built using a super hybrid sensor (S.H.S.) adopted in an  analytical balance. Therefore, the result is more precise and gets greater repeatability.      An analyzer using the S.H.S. has high sensitivity, needs only a sample quantity of a  few grams, and the analysis time becomes shorter.      A 400W halogen lamp is used as the heating source and the temperatur
                    
                    Resumen del contenido incluido en la página 11 
                    
                          The analyzer is equipped with a serial interface as standard. It can be connected to  a printer or computer.      The analyzer can calibrate the weighing sensor (Use special mass.) and drying  temperature (Use temperature calibrator for MS-70 and MX-50 except MF-50 and  ML-50). The analyzer can output the data required at GLP, GMP and ISO at the end  of the calibration.      The analyzer has a self check function that can detect function errors.      The analyzer displays the current change of
                    
                    Resumen del contenido incluido en la página 12 
                    
                        
                    
                    Resumen del contenido incluido en la página 13 
                    
                        
                    
                    Resumen del contenido incluido en la página 14 
                    
                          5. 5. 5. 5.1 1 1 1.... Di Di Di Dis s s sp p p plllla a a ay y y y a a a an n n nd d d d    Ke Ke Ke Key y y ys s s s      4 5 6 7  3    8    2    9      1  10  #2     Name State and Meaning  At gram display Preset time is displayed at timer mode  1 Time  At measurement Analysis time  Temperature of At gram display Set temperature of sample pan  2  sample pan  At measurement Current temperature of sample pan  PROG: Program No. At gram display Program number of measurement program  3  MEM: Data
                    
                    Resumen del contenido incluido en la página 15 
                    
                        
                    
                    Resumen del contenido incluido en la página 16 
                    
                          6. 6. P Pr reparation eparations s     6. 6. P Pr reparation eparations s       6. 6.1 1.. IIn ns st tall alliin ng g the Ana the Anallyz yzer er   6. 6.1 1.. IIn ns st tall alliin ng g the Ana the Anallyz yzer er      1. Select the place to install the analyzer.   Bubble spirit level  Refer "3.1.Installing the Analyzer".     2. Level the analyzer by adjusting the leveling feet  and confirm it using the bubble spirit level.  Leveling foot     3. Read the power supply voltage label on the back 
                    
                    Resumen del contenido incluido en la página 17 
                    
                        
                    
                    Resumen del contenido incluido en la página 18 
                    
                          6. 6.3 3.. Pr Proper oper  O Op per era at tiio on f n fo or r Pr Prec ecis isiio on Me n Mea as sure urem me en nt t   6. 6.3 3.. Pr Proper oper  O Op per era at tiio on f n fo or r Pr Prec ecis isiio on Me n Mea as sure urem me en nt t   6.3.1. 6.3.1. 6.3.1. 6.3.1. Operation of Operation of Operation of Operation of the sample the sample the sample the sample       Use a proper sample quantity. If the quantity is small, precise results may not be possible.    If the moisture content of the s
                    
                    Resumen del contenido incluido en la página 19 
                    
                        6. 6.3. 3.3. 3. T Th he G e Glla as ss F s Fiibe ber r  S Sh hee eet ts s  6. 6.3. 3.3. 3. T Th he G e Glla as ss F s Fiibe ber r  S Sh hee eet ts s     Use the glass fiber sheet to measure the moisture content  that is included in the following samples. When this sheet is  used, vaporization of moisture is speeded up and moisture  measurement result becomes quick and precise.     This accessory (AX-MX-32-1) is a package of 100 glass fiber sheets.    This accessory is inclued in the packing for 
                    
                    Resumen del contenido incluido en la página 20 
                    
                          7. 7. Meas Measur urement Pr ement Proce oced dur ure e   7. 7. Meas Measur urement Pr ement Proce oced dur ure e     7. 7.1 1.. S St tan and da ard rd M Mo od de e O Op pe er rat atio ion n   7. 7.1 1.. S St tan and da ard rd M Mo od de e O Op pe er rat atio ion n       The standard mode can obtain the moisture content with settings of ACCURACY  and drying program (heating pattern, drying temperature).    7.1.1. 7.1.1. 7.1.1. 7.1.1. ACCURAC ACCURAC ACCURAC ACCURACY Y Y Y       ACCURACY of mea