Resumen del contenido incluido en la página 1 
                    
                        Owners Guide 
and 
Installation Instructions 
 
Gas Domestic Indoor 
Water Heater 
 
This water heater must be installed and serviced by an authorised person. 
Please leave this guide with the householder.                                                                                                                                                                                                                                                                                                       
                    
                    Resumen del contenido incluido en la página 2 
                    
                                Notice to Victorian Customers from the  Victorian Plumbing Industry Commission.  This water heater must be installed by a licensed person as required by  the Victorian Building Act 1993.  Only a licensed person will give you a Compliance Certificate, showing that  the work complies with all the relevant standards. Only a licensed person will  have insurance protecting their workmanship for 6 years. Make sure you use  a licensed person to install this water heater and ask for your Complia
                    
                    Resumen del contenido incluido en la página 3 
                    
                          CONTENTS      HOUSEHOLDER – We recommend you read pages 4 to 12.  The other pages are intended for the installer but may be of interest.      About Your Water Heater............................................................4  How Your Water Heater Works...................................................7  Regular Care ................................................................................8  Save A Service Call ...................................................................10  In
                    
                    Resumen del contenido incluido en la página 4 
                    
                          ABOUT YOUR WATER HEATER    MODEL TYPE  ® Congratulations for choosing a Rheem water heater. The model you have  chosen is suitable for indoor installation only. The model is either a 300 series  ® Rheemglas or 620 series Heavy Duty water heater.    HOW HOT SHOULD THE WATER BE?    The water heater features a user adjustable  thermostat, which allows you to personally  choose the most suitable temperature for Heavy Duty maximum  thermostat setting  your hot water needs. Refer to  “Temperature Ad
                    
                    Resumen del contenido incluido en la página 5 
                    
                        ABOUT YOUR WATER HEATER  WARNING  This water heater is not intended to be operated, adjusted or tampered with by  young children or infirm persons. Young children should be supervised to  ensure they do not interfere with the water heater.    SAFETY  • Do not store flammable or combustible  materials near the water heater.  Flammable liquids (such as petrol),  newspapers and similar articles must be  kept well away from the water heater and  the draught diverter.  • Do not use aerosols, stain re
                    
                    Resumen del contenido incluido en la página 6 
                    
                        ABOUT YOUR WATER HEATER  TO TURN ON THE WATER HEATER  • Open the cold water isolation valve fully at the inlet to the water heater.  • Open the gas isolation valve fully at the inlet to the gas control.  • Light the water heater (refer to “Lighting the Water Heater” on page 24).    HOW DO I KNOW IF THE WATER HEATER IS INSTALLED CORRECTLY?  Installation requirements are shown on page 19. The water heater must be  installed by an authorised person and the installation must comply with National  St
                    
                    Resumen del contenido incluido en la página 7 
                    
                          HOW YOUR WATER HEATER WORKS    Water is stored in a vitreous enamel lined steel cylinder and heated by a gas  burner located under the cylinder. The heat produced by the burner is  transferred to the water through the base of the cylinder and through the wall of  a flue pipe which passes through the centre of the cylinder. A flue baffle in this  flue ensures the efficiency of the water heater is correct. The gas supply to the  burner is controlled by the thermostat so the water is heated to a 
                    
                    Resumen del contenido incluido en la página 8 
                    
                          REGULAR CARE    TEMPERATURE PRESSURE RELIEF VALVE  This valve is near the top of the water  heater and is essential for its safe  operation. It is possible for the valve to  release a little water through the drain  line during each heating period. This  occurs as the water is heated and  expands by approximately 1/50 of its  volume.    Continuous leakage of water from the  valve and its drain line may indicate a  problem with the water heater (refer to  “Temperature Pressure Relief Valve  Run
                    
                    Resumen del contenido incluido en la página 9 
                    
                        REGULAR CARE  EXPANSION CONTROL VALVE  In many areas, including South Australia, Western Australia and scaling water  areas, an expansion control valve is fitted to the cold water line to the water  heater. Water will flow from its drain line during the heating period.    Operate the easing lever on the expansion control valve once every six  months. It is very important you raise and lower the lever gently. The  expansion control valve should be checked for performance or replaced at  intervals
                    
                    Resumen del contenido incluido en la página 10 
                    
                          SAVE A SERVICE CALL    Check the items below before making a service call. You will be charged for  attending to any condition or fault that is not related to manufacture or failure of  a part.    NOT ENOUGH HOT WATER (OR NO HOT WATER)  • Are you using more hot water than you think?  Is one outlet (especially the shower)    using more hot water than you think?  Very often it is not realised the amount  of hot water used, particularly when  showering. Carefully review the family’s  hot water us
                    
                    Resumen del contenido incluido en la página 11 
                    
                        SAVE A SERVICE CALL  TEMPERATURE PRESSURE RELIEF VALVE RUNNING  • Normal Operation    It is normal and desirable this valve    allows a small quantity of water to   escape during the heating cycle.  However, if it discharges more than  a bucket full of water in 24 hours,  there may be another problem.  • Continuous dribble  Try gently raising the easing lever  on the relief valve for a few seconds  (refer to “Temperature Pressure  Relief Valve” on page 8). This may  dislodge a small particle of 
                    
                    Resumen del contenido incluido en la página 12 
                    
                        SAVE A SERVICE CALL  CAN’T LIGHT THE PILOT FLAME   • Is there gas to the water heater?  Check the gas isolation valve on the  gas supply line is open.  • Is there a normal gas supply to  the rest of the premises?  Try lighting another gas appliance to  check. If there is no gas, call the gas    supplier.    WATER HEATER APPEARS TO BE LEAKING  When the water heater is first lit, or after a large usage of hot water,  condensation may form on the burner of the water heater. This is quite normal,  e
                    
                    Resumen del contenido incluido en la página 13 
                    
                          INSTALLATION    THIS WATER HEATER IS FOR INDOOR INSTALLATION ONLY.  THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING.  Check the water heater is suitable for the gas type available  (refer to the rating label on the water heater).    Note: The 620 130 heavy duty water heater is designed for small commercial  applications requiring sanitising temperatures and has a maximum temperature  setting of 80 °C. This model should not be installed in a domestic residence.    WATER HEATER LOCATION  The 
                    
                    Resumen del contenido incluido en la página 14 
                    
                        INSTALLATION  Keep the water heater and flue at least  25 mm clear of walls, cupboards, timber or  any other combustibles and at least 500 mm  clear of curtains and furnishings.    The water heater is to be installed at floor  level and must stand vertically upright. There  are special requirements in AS 5601 for water  heaters installed in a garage, an enclosed  space and other locations. Remember all  local authorities have regulations about  putting water heaters into roof spaces.        If i
                    
                    Resumen del contenido incluido en la página 15 
                    
                        INSTALLATION  TANK WATER SUPPLY  If the water heater is supplied with water from a tank supply, then the bottom of  the supply tank must be at least 1 m above the highest hot water outlet. Take  care to avoid air locks. The cold water line to the water heater should be  adequately sized and fitted with a full flow gate valve or ball valve.    HOT WATER DELIVERY  This water heater can deliver water at temperatures which can cause scalding.    It is necessary and we recommend that a temperature li
                    
                    Resumen del contenido incluido en la página 16 
                    
                        INSTALLATION  CIRCULATED HOT WATER FLOW AND RETURN SYSTEM  If a Rheem water heater is to be installed as part of a circulated hot water flow  and return system, a storage water heater able to provide a hot water outlet  temperature of at least 60 °C must be used. Note: The thermostat must always  be set to at least 60 °C. Refer to the diagram on page 16.    Temperature Limiting Device  A temperature limiting device cannot be installed in circulated hot water flow  and return pipe work. The tempe
                    
                    Resumen del contenido incluido en la página 17 
                    
                        INSTALLATION  REDUCING HEAT LOSSES  The cold water line to and the hot water line from the water heater must be  insulated in accordance with the requirements of AS/NZS 3500.4. The  insulation must be weatherproof and UV resistant if exposed.    ANODE TYPES  The correct anode type for the water supply being used must be fitted in the  water heater (refer to “Water Supplies” on page 30). The black anode is fitted  as standard.    Total Dissolved Solids in water supply to the water heater Anode co
                    
                    Resumen del contenido incluido en la página 18 
                    
                        INSTALLATION  DIMENSIONS AND TECHNICAL DATA          300 135    Model 300 170      620 130  Storage capacity litres 135 170       kg  Mass (tank)  Empty 54 63       kg   Full 189 233                        Dimensions A B C D E F G H K L M   130 / 135 mm 1615 425 500 988 328 297 1490 58 490 213 75    170 mm 1915 425 500 1213 403 297 1790 58 490 213 75    Hourly Gas Min. Gas Test Point Gas Max. Gas  Gas Details  Consumption (MJ) Pressure (kPa) Pressure (kPa) Pressure (kPa)   130, 135 170 130 to 17
                    
                    Resumen del contenido incluido en la página 19 
                    
                        INSTALLATION  TYPICAL INSTALLATION – INDOOR LOCATION            19                                                                                                                                                                                                                                                                                                                                                                                                                                                  
                    
                    Resumen del contenido incluido en la página 20 
                    
                          CONNECTIONS – PLUMBING    CONNECTION SIZES  • Hot water connection: RP¾/20.  • Cold water connection: RP¾/20.  • Relief valve connection: RP½/15.  • Gas inlet: RP½/15.    All plumbing work must be carried out by a qualified person and in accordance  with the National Plumbing Standard AS/NZS 3500.4 and local authority  requirements.    All gas work must be carried out by a qualified person and in accordance with  the Australian Gas Installations Standard AS 5601 and local authority  requiremen